Do you have a question about the DZB200M and is the answer not in the manual?
Questions and answers
Summary of Contents for Fulling DZB200M
Page 1
DZB200 INVERTER M & J S af et y a nd Cau tio ns P r o du ct I ntr oduc tio n Mec h an ica l a nd El ectr i cal I ns ta ll ati o n O per a tio n a n d D is pla y Func ti o n Pa ra m eter s L is t P a ram e t e r De scri ptio n...
Page 2
DZB Series Preface Preface Thank you for choosing DZB 200M&J Series AC Motor D rives. This manual will be helpful in the installation, parameter setting, t rou bleshooting, and daily maintenance of the AC motor drives. To guaran tee safe operation of the equipment,read the following safety guidelines before connecting power to the AC drives.
Index Chapter 1 Safety and Cautions Chapter 2 Product Introduction Chapter 3 Mechanical and Electrical Installation Chapter 4 Operation and Display Chapter 5 Function Parameters List Chapter 6 Parameter Description F0 Basic F unctio n Parameters F1 Motor Param eters F2 Input and Output Terminal Function Parameter s F3 Human Machine Interface Parameters F4 Application Function Parameters...
DZB Series DZB Series C hapter 1 Safe ty and Cautions Chapte r 1 S afety and Cau tions Chapter 1 Safety and Cautions Note Safety Definition ★ Do not connect t he input ter minals with the output terminals (U, V, W), oth erwis e the inverter There are two kinds of safety cautions in the manual: may be damaged! ★...
Page 5
DZB Series DZB Series Chapter 1 Safe ty and Cautions Chap ter 1 S afety and Cautions Cautions Note 1. Check the Insulation of t he Motor ★ If parameter identification is required, please pay a ttent ion that the rotating motor ma y injure When the motor is used for the fi rst time, or reused after storing for a long time, or in regular checkup, peopl e, otherwise accident may occur! the user m ust check t he insulati on of the motor t o prevent the poor insulation of t he windings of mot or from...
DZB Series DZB Series Chapter 1 Safe ty and Cautions Chapter 2 Product Introduction Chapter 2 Product Introduction 11. Special Usages T he user can consult our compa ny if he wants to use another method instead of the recommended connecting method provide d in the manual, such as shared DC bus.
DZB Series DZB Series C hapter 2 Prod uct Introduction Chapter 3 M echanic al and Electrical Installation Chapter 3 Mechanical and Electrical Installation 2.2 Nameplate Information Mechanical Installation Nameplate 1. I nstallation Envi ronment 1) Ambient temperature: Ambient temperature influences the inverter life greatly, s o it should be within ℃...
Page 8
Power source (1PH) below. 1) DZB200M series inverter standard wiring diagram.If onl e usi ng th e panel o perate th e inverter, just wiring th e ma in ci rcuit. brake resistance(option)
Page 9
DZB Series DZB Series Chapter 3 Mechanical and Ele ctrical Installation Chapter 3 M echanic al and Electrical Installation Main Circuit Wiring Danger INPUT ★ Please confirm the mains vol tage level is same with that of the inverter, ot herwi se the inverter may be damaged! ★...
Page 10
DZB Series DZB Series Chapter 3 Mecha nical and Ele ctrical Installation Cha pter 3 Mechanical and E lectrical Installation 3)No t e s o n C o ntro l Te r mi na l s : E. Grounding Terminal Grounding Terminal must be connected to earth re liably and the grounding resistance shall be less than A) Analog input terminal: Ω...
Page 11
DZB Series DZB Series C hapter 3 Mechanical and Electr ical Insta llation Chapter 3 M echanic al and Electrical Installation 2) Reducing the dis turbance to the in ver ter from othe r equipme nt Note: Pay attention to the polarity of the dio de as shown in the figur e 3-8. Otherwise if the digital The re lay, contactor or ele ctro nic -magnetic br aking device wil l disturb t he inve rter.
Page 12
DZB Series DZB Series Chapter 4 Op eration and Display Chap ter 4 Operation a nd Displa y Chapter 4 Digital Keypad Operation Expl anati on of Screen Display Description of the Digital Keypad Explanation of Displayed Messages on Running status r ( efer to F 3.05): ●...
Page 13
DZB Series DZB Series Chapte r 4 O peration and Displ ay Cha pter 4 Operat ion and Display 4. 2 Modify and Check t he Function Codes In third level menu, if the parameter has no f lash bit, it m eans the function c ode ca nnot b e changed and DZB 200 series inverter's operation panel uses 3-level m enu to conduct pa rameter set tings.
DZB Series DZB Series Chapter 5 Functio n Parame ters List Chapter 5 Function Parameters List Chapter 5 Function parameters list Function Default Modifi Serial Settin g Range Nam e ca tio n Code Value DZB200series i nvert er funct ion para meters, which are grouped by func ti ons, have F0-F0 total 7 groups. F0 Basic Function Parameters Each functi on group includes a numbe r of function codes, which adopt s t hree-stage menu, for i nstance, “...
Page 15
DZB Series DZB0 Series Chapter 5 Functio n Parame ters List Chapter 5 Function Parameters List Function Defa ult Function Modifi Serial De fault Modifi Serial Settin g Range Setting R ange Name Name cation Code Value Code Value cat ion :...
Page 16
DZB Series DZB Series Chapter 5 Functio n Parame ters List Chapter 5 Function Parameters L ist Function Defa ult Function De fault Modifi Serial Modifi Ser ial Settin g Range Settin g R ange Name Name cation cation Code Value Code Value...
Page 17
DZB Series DZB Series Chapter 5 Function Parameters L ist Chapter 5 Function Parameters List Function De fault Function Default Modifi Serial Modifi Serial Settin g Ran ge Setting Range Name Name cation ca tio n Code Value Code Value :...
Page 18
DZB Series DZB Series Chapter 5 Functio n Parame ters List Chapter 5 Function Parameters List Function Default Function Default Modifi Serial Modifi Serial Setting Range Setting Range Name Name cation ca tio n Code Value Code Value 7:Accelerati on over-voltage(E002) ~...
Page 19
DZB Series DZB Series Chapter 5 Functio n Parame ters List Chapter 5 Function Parameters List Function Default Function Default Modifi Serial Modifi Serial Setting Range Setting Range Name Name cation ca tio n Code Value Code Value Proportional gain (Kp) ~...
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description Chapter 6 Parameter Description Function D efault Modifi Seria l Sett ing Range Name cation Cod e Value F0 Basic Function Parame ters : 3 No alar m an d stop accor ding to Functio n st op mode(by all control mode) Default...
Page 21
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description : 0: Val id, and the inverter memorizes when power down. Able to set up frequency command, and memorize 6 Remote communicati on thi s set frequency when the invert er is power down. When the power is back,automatically combine it with The frequency command is given in the communication mode by upper position machine.For det ails, “...
Page 22
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description Output frequency f Functio n Default Setting Range Name Cod e Value Set by m ax Carr ier frequ ency setti ng ~ F0.11 1.0 15 .0kHz model s e t Carrier...
Page 23
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description starting frequency, inverter does not ope rat e and is at stand-by st ate. The st art ing frequency value is not Function Default Setting Range Name Code Value...
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description 0: Terminal command inval id when power on. Inverte r will not run i f it detect operating command terminal O u t p u t F r e q u e n c y f i s valid.
Page 25
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description Output Volta ge (V) Function Default Setting Range Nam e Code Value ~ Up per torque limit setting 0.0 20 0.0%(inverter r ate d c urrent) 150.0% F1.19 The setting 100.0% is c orresponding to the rat ed output current.
Page 26
DZB Series DZB Series Chapter 6 Parameter Description Cha pter 6 Parameter Descr iption Functio n Default Setting Range Name When the freque ncy is set by external te rmina l, modify the Cod e Value Frequency frequency up and down command. When the frequency F2.
Page 27
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description Function Default Setting Range Name Code Value 2: Three- wire control 1, integrate Enable with di rection. At this mode, EN is the Enable terminal with the :...
Page 28
DZB Series DZB Series Chapter 6 Para meter Description Chapter 6 Param eter Descri ption Functio n Default Funct ion Default Setting Range Name Setting Range Name Cod e Value Code Value ~ UP/DOWN frequency F2.14 CI lower lim it 0.0V 10.0V 0.0 V ~...
Page 29
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description low pressure reaches Pressure reaches at the F7.13 low pressure setting,NO output indication 10V(20mA) detection(NO) signal. sleeping satus indicates During sleeping status,output ON signal and display "EOPP" no water indicates No water alarms,output ON signal and display "EOP2"...
Page 30
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description , Option: sett ing para meter=the sum total of displ ay code for exa mple: Function Default Setting Range Nam e Code Value require to display at operation st at us:Out put current,Running spe ed,Output power 4+16+32=52, then :...
Page 31
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description Function Default Functio n Default D escription Setting Range Nam e Name Code Cod e Value Value The output frequency when current ~ Operating frequen cy at Jogging frequency F4.02 0.00 F0.04...
Page 32
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description Tra verse freque ncy functi on is suitable to industries such a s textile, fi ber and so on, and to applications which require traversing and w indi ng functions. Out put fr equen cy Tra verse freque ncy functi on means that the invert er output frequency i s traversi ng up and down around the set frequency.
Page 33
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description When frequency source is chosen to be PID, i.e. F0.03 is chosen to be 5, these group functions are a ctive. Function Default Setting Range Nam e Code Value...
Page 34
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description Proport ional gain (Kp): det ermi nes the adjusting st rength of PID adjust or. The bigger the P, the bigger Functio n Default Setting Range Name Cod e Value...
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description 、 、 Relationship bet ween multi -speed and S 1 S2 S3 terminals Function Default Setting Range Nam e Code Value Current seg me nt o f mu lti-sp eed con trol ~...
Page 36
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description Function Default Functio n Default Setting Range Setting Range Nam e Name Code Cod e Value Value ~ : Motor Ove rload 20.0% 120.0% 0 prohibit Over -voltage F5.0 1 100.0%...
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description Functio n Default Setting Range Name Cod e Output current Value ( ) Data pattern 0:N o check N,8,1 for RTU F6.02 Auto limit current level (...
Page 38
DZB Series DZB Series Cha pter 6 Parameter D es cription Chapter 6 Parameter Description Functio n Default DATA Frame:8-E-1 Setting Range Name Cod e Value Start Even Stop Co mmun icat io n ~ F6.03 0 200ms bit0 bit1 bit2 bit3 bit4 bit5 bit6 bit7 r esponse d ela y 8-data bits...
DZB Series DZB Series Chapter 7 Fault Dia gnosis and Countermeasure s Chapter 7 Fault Diagnosis and Counte rmeasures Chapter 7 Fault Diagnosis and Countermeasures 1. Under voltage of DC Bus(E001) DZB200 has 25 pie ces of alarm information and protec ti on func tions in t otal. Once the fault occurs, Tran sie nt powe r cu t exists or not m otor driver inverte r reset the protecti on functi on starts, the inverter stops inputti ng, t he fault relay contact poi nt is activated, and the...
Page 40
DZB Series DZB Series Chapter 7 Fault Dia gnosis and Countermeasure s Chapter 7 Fault Diagnosis and Counte rmeasures 3. Over vol tage during runni ng(E003) 5. Over current during deceleration(E005) C he ck if the out put loo p o f the mo tor d river Adjust the voltage within Remove th e peripheral fa ult The inp ut volta ge is t oo high or not...
Page 41
DZB Series DZB Series Chapter 7 Fault Dia gnosis and Countermeasure s Chapter 7 Fault Diagnosis and Counte rmeasures 7. Motor Over Load(E007) 10. Over voltage during deceleration(E00A) Adjust the v oltage within The moto r prot ection parameter The inpu t vol tage is too high o r not Correctly set up the parameter norm al ran ge F5 .01 set ti ng is suitable or not...
Page 42
DZB Series DZB Series Chapter 7 Fault Dia gnosis and Countermeasure s Chapter 7 Fault Diagnosis and Counte rmeasures 13. EEPROM read-write failure(E00F) 16. Current Inspection Circuit Failure(E015) Whether it is normal af ter t he Change Hall device Che ck if Hall de vice is normal main co nt rol bo ard f ault renewal of th e main cont rol board C hange drive board...
DZB Series DZB Series Chapter 8 Quality Guarantee Appendix A Stan dard Specifications Appendix A: Standard Specifications Chapter 8 Quality Guarantee Quality gua rantees of our produc ts is transacted as the following rules and re gulations: 1.1 Tec hnical Spe cification 8.1 Responsibility of manufacturer: Series DZB200...
DZB Series DZB Series Appen dix A St andard Sp ecifications App endix B Dimensions Appendix B Dimensions Series DZB200 Item Specification pre-set frequency;operate frequency;output current;motor speed;input voltage; Dimensions and Applicable Moter LCD Display output voltage;input/output terminals'status;fault informa tion,etc Operation/Stop,FWD/REV,Function indication,etc LED Status indication (...
DZB Series DZB Series Appendix B Di mensions Appendix C Access ories List Appendix C Accessories List 1 . A l l B r a ki n g R e s i s t o r s & B ra k i n g U n i t s U s e i n A C dr i v e s Product each parts of names Braking Resistors Model No.of Units Used Appli cable Moter...
Page 46
A card of user's protect to fix card Model: Invoice number: Number: Buy date of machine : Manufacturer: Tel: User: Tel: Address: Post code: Maintain Date: Detailed record: Note:User writes the card and mails it to the manufacturer during ten days.
Page 47
B card for user's file Model: Invoice number: Number: Buy data of machine: Honorific cu stome r: Welcome to use FuLing Inverte r ! 、 1 You hav e the" three guarantees" from the time that you buy the machine.Because of the quality of th e prod ucts,you have the ser- vices as follows: 1)Return the machine in one month.
Need help?
Do you have a question about the DZB200M and is the answer not in the manual?
Questions and answers