Ahlborn ALMEMO 1030 Operating Instructions Manual

Precision temperature measuring instrument for pt100 sensors
Table of Contents

Advertisement

Quick Links

____________________________
Operating instructions
ALMEMO
®
1030
Precision temperature measuring instrument
for Pt100 sensors
V1.0
26.01.2011
www.ahlborn.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALMEMO 1030 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ahlborn ALMEMO 1030

  • Page 1 ____________________________ Operating instructions ALMEMO ® 1030 Precision temperature measuring instrument for Pt100 sensors V1.0 26.01.2011 www.ahlborn.com...
  • Page 2: Operating Controls

    1. Operating controls 1. OPERATING CONTROLS (1) Measuring inputs M0 and M1 M0..M1 Pt100 sensor Differential (2) Sleep-LED (3) Output socket A2 SD memory connector (ZA1904-SD) (4) Output socket A1 V24 interface (ZA 1909-DK5) Optic fiber (ZA 1909-DKL) USB (ZA 19019-DKU) Ethernet (ZA 1945-DK) (5) Socket, DC, 12 V Mains adapter (ZA1312NA1,12V,0.2A)
  • Page 3: Table Of Contents

    Table of Contents 2. TABLE OF CONTENTS 1. OPERATING CONTROLS................2 3. GENERAL....................5 3.1 Warranty....................5 3.2 Standard delivery................5 3.3 Handling batteries / rechargeable batteries correctly......5 3.4 Special notes on use................6 4. INTRODUCTION..................6 4.1 Sensor programming................6 4.2 Measuring operation................6 5. PUTTING INTO SERVICE................8 6.
  • Page 4 2. Table of Contents 12.5 Memory capacity, memory output, clearing the memory.....20 12.6 Memory time available..............20 12.7 Sleep mode..................20 12.8 Starting and stopping measuring operations.......21 13. SENSOR PROGRAMMING..............22 13.1 Measuring point designation............22 13.2 Multi-point calibration..............22 13.3 Resolution and units...............22 13.4 Smoothing by means of a sliding average ........22 14.
  • Page 5: General

    General 3. GENERAL We should like to congratulate you on your purchase of this new and innovative ALMEMO ® precision temperature measuring instrument (with 0.001 K resolution). 3.1 Warranty Each and every device, before leaving our factory, undergoes numerous quali- ty tests.
  • Page 6: Special Notes On Use

    3. General Batteries / rechargeable batteries must never be short-circuited or thrown onto the fire. Batteries / rechargeable batteries are special waste and must not be discarded as normal domestic waste. 3.4 Special notes on use ● Before using the mains adapter make sure that the mains voltage is suitable. ●...
  • Page 7 Measuring operation Measured value smoothing For both measuring channels measured values of an unstable, fluctuating na- ture can be smoothed by taking a sliding average over a number of values pro - grammable from 2 to 99. Maximum and minimum values For each measuring operation the maximum value and minimum value are ac- quired and saved to memory.
  • Page 8: Putting Into Service

    Press once and release key (7) s. Section 6.4 ON / PROG Automatic display of the measuring menu see Chapter 10. To call up the menu selection screen press: ALMEMO 1030 <MENU> To activate / deactivate M*Measuring menu Mªª © < ON>...
  • Page 9: Power Supply

    Power supply 6. POWER SUPPLY Power can be supplied to the measuring instrument in any of the following ways: 3 AA alkaline batteries (included in delivery) Mains adapter, 12 V, 0.2 A, with ALMEMO ® connector ZA 1312-NA1 Power supply cable, electrically isolated (10 to 30 VDC, 0.25 A) ZA 2690-UK Our product spectrum includes all the appropriate accessories.
  • Page 10: Switching On / Off, Reinitialization

    6. Power supply 6.4 Switching ON / OFF, reinitialization To switch the device ON press (6) located in the middle of the cursor ON PROG block. The measuring menu always appears in the display first. To switch OFF press and hold down the same key(s) .
  • Page 11: Measuring Inputs And Additional Channels

    Sensors / transducers gned to protect the socket unit against penetration by splashing water. For any unused sockets protective stoppers are available. 7.2 Measuring inputs and additional channels Each ALMEMO ® 1030 measuring instrument incorporates two input sockets (1) to which measuring channels M0 and M1 are assigned.. Device-internal channels: This device also incorporates additional channel M2, which is programmed as differential channel M1 –...
  • Page 12: Display And Keypad

    LCD with 128x64 pixels or 8 rows each 8 pixels high. The menu selection screen offers the following items: Meas. menu for acquiring meas. values (s. 10), ALMEMO 1030 Memory functions menu see 11 Also accessible M*Measuring menu Mªª...
  • Page 13: Function Keys

    Measured value display and status symbols In the first data logger menu the top status bar also displays the following symbols for checking the measuring sequence: ll or © Measurement stopped or started: Measuring point scan started with data saving: Measuring point scan started with data output via interface: Start time or end time of measuring operation programmed: l©...
  • Page 14: Entering Data

    8. Display and keypad Help is provided by the softkey symbol: <F> for function selection To jump forward to the next function press: ▲ ▼ Depending on function the keys are assigned ◄ ► the desired meaning. e.g. To set the measured value to zero <ZERO>...
  • Page 15: Menu Selection Screen

    Menu selection screen 9. MENU SELECTION SCREEN Via the menu selection screen the following menus can be accessed. (see Section 8.1) ALMEMO 1030 M Measuring menu see Chapter 10 M*Measuring menu Mªª © M Memory functions menu see Chapter 11...
  • Page 16: Functions Menu

    11. Functions menu 11. FUNCTIONS MENU REL º ´´´´´´µµµµ¶ It is possible, via the functions menu, to acquire 0: 154.512 °C maximum and minimum values over specifiable periods of time or to save measured values at P304 Reference 2 specifiable locations or points in time. Measu- Min: 135.374 Max: 161.349 Memory: P12: 125.454°C...
  • Page 17: Maximum / Minimum Memory

    Maximum / minimum memory 11.3 Maximum / minimum memory functions menu shows not only the measu- REL º ´´´´´´µµµµ¶ red value with designation but also the conti- 0: 154.512 °C nuously acquired maximum and minimum va- lues for the measuring point selected. P304 Reference 2 Min: 135.374 Max: 161.349 Memory:...
  • Page 18: Data Logger

    12. Data logger 12. DATA LOGGER Measuring instrument ALMEMO ® 1030 can be ALMEMO 1030 made into a respectable data logger - by fitting M Measuring menu Mªª © memory connector ZA1904SD with a micro-SD M Max-Min, Memory memory card (available as an accessory).
  • Page 19: Date And Time-Of-Day

    Date and time-of-day 12.2 Date and time-of-day For logging data recordings a real-time clock with date and time-of-day is provi- ded. This real-time clock is buffered by means of the device battery; in the event of battery replacement date and time-of-day are lost. The first line con - tains the time-of-day on the left and the date on the right;...
  • Page 20: Memory Capacity, Memory Output, Clearing The Memory

    12. Data logger 12.5 Memory capacity, memory output, clearing the memory Memory free While measured values are being recorded the ´ ´ function conti- nuously displays the memory capacity still available. Selecting this function enables two softkeys, one for direct memory output and one for memory clea- ring.
  • Page 21: Starting And Stopping Measuring Operations

    Sleep mode the specified cycle, performs one measuring point scan, and then switches off again. 6. To quit sleep mode press: <ON> 7. To terminate the measuring operation press <STOP>  When selecting sleep mode, subject to confirming a check window, all necessary parameters may be configured.
  • Page 22: Sensor Programming

    13. Sensor programming 13. SENSOR PROGRAMMING Sensors for measuring instrument ALMEMO ® 1030 incorporate in the connec- tor a small memory chip ensuring they are automatically recognized when plug- ged in. It is also possible to program certain parameters (e.g. assigning the sensor a name), to change the units, or, with a view to stabilizing the display, to set a smoothing SENSOR PROGRAMMING...
  • Page 23: Device Configuration

    Measured value smoothing over e.g. 15 values: Smoothing: Time constant (s) = smoothing / 2.5 mops * 2 = 3 seconds 14. DEVICE CONFIGURATION DEVICE CONFIGURATION Designation. ALMEMO 1030 In the ´ Device configuration ´ menu certain basic Language: English settings can be made, e.g.
  • Page 24: Interface, Data Cable, Baud Rate, Data Format

    14. Device configuration If display illumination is enabled, the following symbol appears in the status bar: Illumination ON If illumination has temporarily switched off, the following will light up Pause To switch ON again without this function press: ◄ To set the contrast (5 to 100 %) press Contrast: <...
  • Page 25: Declaration Of Conformity

    "Function test" in the device list or terminal mode. 16. DECLARATION OF CONFORMITY Ahlborn Mess- und Regelungstechnik GmbH declares herewith that the ALME- ® 1030 device carries the CE label and complies in full with the require- ments of EU directives relating to low voltage and to electromagnetic compati- bility (EMC) (89/336/EWG).
  • Page 26: Annex

    17. Annex 17. ANNEX 17.1 Technical data Measuring inputs 2 ALMEMO ® sockets, suitable for ALMEMO ® flat connectors Measuring channels 1 additional channel for differential Measuring range From -200 to +400 °C Resolution 0.001 K / 0.01 K Linearization accuracy 0.001 K Measuring current 1 mA...
  • Page 27: Index

    Index 17.3 Index Accessories 17.2 additional channels Battery operation baud rate 14.4 Connecting sensors contrast 14.3 Cyclic output 12.4 Data buffering data cable 14.4 data format 14.4 Data logger Date and time-of-day 12.2 Declaration of conformity Device configuration Device designation 14.1 Device-internal channels differential channel...
  • Page 28: Almemo

    17. Annex Memory capacity 12.5 memory card 12.1 Memory connector 12.1 memory output 12.5 Memory time 12.6 menu selection Menu selection Multi-point calibration 13.2 Once-only output 12.3 Order no 17.2 Outputs 17.1 Potential separation Power supply 17.1 9, 26 Product overview 17.2 Putting into service reinitialization...