Table of Contents 2. TABLE OF CONTENTS 1. OPERATING CONTROLS................2 3. GENERAL....................5 3.1 Warranty....................5 3.2 Standard delivery................5 3.3 Handling batteries / rechargeable batteries correctly......5 3.4 Special notes on use................6 4. INTRODUCTION..................6 4.1 Sensor programming................6 4.2 Measuring operation................6 5. PUTTING INTO SERVICE................8 6.
Page 4
2. Table of Contents 12.5 Memory capacity, memory output, clearing the memory.....20 12.6 Memory time available..............20 12.7 Sleep mode..................20 12.8 Starting and stopping measuring operations.......21 13. SENSOR PROGRAMMING..............22 13.1 Measuring point designation............22 13.2 Multi-point calibration..............22 13.3 Resolution and units...............22 13.4 Smoothing by means of a sliding average ........22 14.
General 3. GENERAL We should like to congratulate you on your purchase of this new and innovative ALMEMO ® precision temperature measuring instrument (with 0.001 K resolution). 3.1 Warranty Each and every device, before leaving our factory, undergoes numerous quali- ty tests.
3. General Batteries / rechargeable batteries must never be short-circuited or thrown onto the fire. Batteries / rechargeable batteries are special waste and must not be discarded as normal domestic waste. 3.4 Special notes on use ● Before using the mains adapter make sure that the mains voltage is suitable. ●...
Page 7
Measuring operation Measured value smoothing For both measuring channels measured values of an unstable, fluctuating na- ture can be smoothed by taking a sliding average over a number of values pro - grammable from 2 to 99. Maximum and minimum values For each measuring operation the maximum value and minimum value are ac- quired and saved to memory.
Power supply 6. POWER SUPPLY Power can be supplied to the measuring instrument in any of the following ways: 3 AA alkaline batteries (included in delivery) Mains adapter, 12 V, 0.2 A, with ALMEMO ® connector ZA 1312-NA1 Power supply cable, electrically isolated (10 to 30 VDC, 0.25 A) ZA 2690-UK Our product spectrum includes all the appropriate accessories.
6. Power supply 6.4 Switching ON / OFF, reinitialization To switch the device ON press (6) located in the middle of the cursor ON PROG block. The measuring menu always appears in the display first. To switch OFF press and hold down the same key(s) .
Sensors / transducers gned to protect the socket unit against penetration by splashing water. For any unused sockets protective stoppers are available. 7.2 Measuring inputs and additional channels Each ALMEMO ® 1030 measuring instrument incorporates two input sockets (1) to which measuring channels M0 and M1 are assigned.. Device-internal channels: This device also incorporates additional channel M2, which is programmed as differential channel M1 –...
LCD with 128x64 pixels or 8 rows each 8 pixels high. The menu selection screen offers the following items: Meas. menu for acquiring meas. values (s. 10), ALMEMO 1030 Memory functions menu see 11 Also accessible M*Measuring menu Mªª...
8. Display and keypad Help is provided by the softkey symbol: <F> for function selection To jump forward to the next function press: ▲ ▼ Depending on function the keys are assigned ◄ ► the desired meaning. e.g. To set the measured value to zero <ZERO>...
11. Functions menu 11. FUNCTIONS MENU REL º ´´´´´´µµµµ¶ It is possible, via the functions menu, to acquire 0: 154.512 °C maximum and minimum values over specifiable periods of time or to save measured values at P304 Reference 2 specifiable locations or points in time. Measu- Min: 135.374 Max: 161.349 Memory: P12: 125.454°C...
Maximum / minimum memory 11.3 Maximum / minimum memory functions menu shows not only the measu- REL º ´´´´´´µµµµ¶ red value with designation but also the conti- 0: 154.512 °C nuously acquired maximum and minimum va- lues for the measuring point selected. P304 Reference 2 Min: 135.374 Max: 161.349 Memory:...
Date and time-of-day 12.2 Date and time-of-day For logging data recordings a real-time clock with date and time-of-day is provi- ded. This real-time clock is buffered by means of the device battery; in the event of battery replacement date and time-of-day are lost. The first line con - tains the time-of-day on the left and the date on the right;...
12. Data logger 12.5 Memory capacity, memory output, clearing the memory Memory free While measured values are being recorded the ´ ´ function conti- nuously displays the memory capacity still available. Selecting this function enables two softkeys, one for direct memory output and one for memory clea- ring.
Sleep mode the specified cycle, performs one measuring point scan, and then switches off again. 6. To quit sleep mode press: <ON> 7. To terminate the measuring operation press <STOP> When selecting sleep mode, subject to confirming a check window, all necessary parameters may be configured.
13. Sensor programming 13. SENSOR PROGRAMMING Sensors for measuring instrument ALMEMO ® 1030 incorporate in the connec- tor a small memory chip ensuring they are automatically recognized when plug- ged in. It is also possible to program certain parameters (e.g. assigning the sensor a name), to change the units, or, with a view to stabilizing the display, to set a smoothing SENSOR PROGRAMMING...
Measured value smoothing over e.g. 15 values: Smoothing: Time constant (s) = smoothing / 2.5 mops * 2 = 3 seconds 14. DEVICE CONFIGURATION DEVICE CONFIGURATION Designation. ALMEMO 1030 In the ´ Device configuration ´ menu certain basic Language: English settings can be made, e.g.
14. Device configuration If display illumination is enabled, the following symbol appears in the status bar: Illumination ON If illumination has temporarily switched off, the following will light up Pause To switch ON again without this function press: ◄ To set the contrast (5 to 100 %) press Contrast: <...
"Function test" in the device list or terminal mode. 16. DECLARATION OF CONFORMITY Ahlborn Mess- und Regelungstechnik GmbH declares herewith that the ALME- ® 1030 device carries the CE label and complies in full with the require- ments of EU directives relating to low voltage and to electromagnetic compati- bility (EMC) (89/336/EWG).
17. Annex 17. ANNEX 17.1 Technical data Measuring inputs 2 ALMEMO ® sockets, suitable for ALMEMO ® flat connectors Measuring channels 1 additional channel for differential Measuring range From -200 to +400 °C Resolution 0.001 K / 0.01 K Linearization accuracy 0.001 K Measuring current 1 mA...
Index 17.3 Index Accessories 17.2 additional channels Battery operation baud rate 14.4 Connecting sensors contrast 14.3 Cyclic output 12.4 Data buffering data cable 14.4 data format 14.4 Data logger Date and time-of-day 12.2 Declaration of conformity Device configuration Device designation 14.1 Device-internal channels differential channel...