18. PROTECTION HIST.
The history of protection function is displayed.
After selecting the sub-menu, press the "STRAIGHT"
key, and the history will be erased.
Last
History1
History2
History3
19. DSP P.C.B. CHECK
Whether the bus of DSP P.C.B. is connected properly or
not is self-diagnosed.
TI1 (DSP1) BUS
TI1 (DSP1, IC534) data bus check is executed.
TI2 (DSP2) BUS
TI2 (DSP2, IC567) data bus check is executed.
Display
WAIT
Bus is being checked.
NoEr
No error detected.
DATA
Data bus shorted or open.
RSCS
/RAS or /CAS shorted, or open.
ADDR
Address bus shorted or open.
58
18.PRTCT HIST.
Last :NoPRT
18.PRTCT HIST.
Hist1:Dc 034H
18.PRTCT HIST.
Hist2:Dc 035H
18.PRTCT HIST.
Hist3:NoPRT
19.DSP CHECK
TI1 BUS:NoEr
19.DSP CHECK
TI2 BUS:NoEr
Description
18. PROTECTION HIST.
プロテクション履歴を表示します。
サブメニューを選んだ後、 STRAIGHT キーを押すと
履歴は消去されます。
Last
History1
History2
History3
19. DSP P.S.B. CHECK
DSP P.C.B. のバス接続の正否を自己診断します。
TI1(DSP1)BUS
TI1(DSP1、IC534)のデータバスチェックを行います。
TI2(DSP2)BUS
TI2(DSP2、IC567)のデータバスチェックを行います。
表示
WAIT
バスチェック中
NoEr
不良検出なし
DATA
データバスの短絡・解放
RSCS
/RAS または /CAS の短絡・解放
ADDR
アドレスバスの短絡・解放
判断