SCENT PUMP
A scent pump will automatically add a fragrance
to the steam room during the high temperature
bather cycle. The pump requires a separate 120
Volt 5 Amp electrical supply. The pump comes
complete with all hardware for installation.
It is important that only pure essential oils be used
with the Relax-A-Mist scent pump. Call 1-800-
987-8326 for details. Note: the pump Warranty
may be void if corrosive or alternate products are
used.
MODEL
WATTS
SINGLE PHASE
VOLTS
THREE PHASE
VOLTS
CAUTION CAUTION CAUTION CAUTION
1.
Do not interconnect or manifold steam pipes, reduce in size or cause a restriction.
2.
Use only the steam nozzles supplied, one steam nozzle per steam pipe.
3.
The steam pipe(s) must not be restricted to - the equivalent of less than the inside diameter of
the steam nozzle(s). See Figure 1 for steam pipe and steam nozzle diameter.
4.
Steam Nozzles must be located in an area where the steam will not discharge onto the users'
pathways and the steam will not burn anyone. Note: A steam guard may be required.
5.
AVOID A STEAM TRAP. All condensate MUST be able to drain from all sections of the
steam pipe at all times.
6.
Impure, mineralized, or other types of hard water that may hamper the operation of the steam
generator may VOID THE WARRANTY if not treated properly.
7.
Check the electric service voltage and phase requirements of your Relax-A-Mist steam
generator to ensure your electrical supply is compatible. Use copper wire only.
8.
A remote switch that is connected to the terminals in the low voltage side of the electrical
control box must be capable of handling 3 Amps at 24 volts AC.
9.
Flush 5 gallons of water through the water supply line to remove construction debris before
completing the water connection to the steam generator.
INSTALLATION INSTRUCTIONS FOR SG SERIES
SG-9, SG-14, SG-18, SG-23, SG-27, SG-36
`
Electrical specifications of the Relax-A-Mist steam generators are:
SG-9
SG-14
9,000
13,500
240
240
208
208
208
208
480
480
575
575
NO STEAM SWITCH
For temporary shut down purposes, a no steam
switch can interrupt steam from being produced.
Some examples of when this may be required are:
if the facility decides to have the steam room
cleaned during the daily operation, should a steam
patron require assistance in the steam room, or
should the facility not have patrons present that
day.
Figure 2
SG-18
SG-23
18,000
22,500
240
240
208
208
208
208
480
480
575
575
Call
1-800-987-8326
SG-27
SG-36
27,000
36,000
-
-
-
-
208
208
480
480
575
575
Page 5
for
details.