Dual-Technology, Digital MW/PIR Intrusion Detector
1 1 1 1 . INTRODUCTION
. INTRODUCTION
. INTRODUCTION
. INTRODUCTION
The Scantronic 460 is a digital, microprocessor-controlled MW /
PIR detector that can be adapted to the size of the protected area
by use of a model selector. A different digital signal processing
(DSP) is used upon selection of each model, thus optimizing both
PIR and MW performance within the protected area.
The PIR section of the Scantronic 460 employs a sphere-shaped
lens with cylindrical elements (patented) for uniform detection
sensitivity over the full range of 12 meters (40 ft). Advanced True
Motion Recognition™ algorithm (patented) allows the Scantronic
460 to distinguish between the true motion of an intruder and any
other disturbances which cause false alarms.
A TST (Test) input permits switching the detector to the walk test
mode remotely without removing the front cover. An on-board
motion event jumper determines whether 1 or 2 consecutive
motion events would trigger an alarm.
2 2 2 2 . SPECIFICATIONS
. SPECIFICATIONS
. SPECIFICATIONS
. SPECIFICATIONS
Selectable Models: Models covering 6, 9 and 12 meters (20, 30
and 40 ft), selected upon installation
Input Voltage: 9 to 16 VDC
Current Drain: About 20 mA @
12 VDC
PIR SECTION (see Figure 3)
Lens Data
No. of curtain beams: 9 + 5
Max. Coverage: 12 x 12 m
(40 x 40 ft) / 90°
Tripping Indication: Indicator
lights ORANGE for about 3 sec.
MW SECTION
Oscillator type: Microstrip,
DRO-stabilized
Frequency: 2.45 GHz
Detection Range: Up to 12 m
Tripping Indication: Indicator
lights GREEN for about 3 sec.
ALARM and TAMPER
Alarm Output: Solid-state relay, N.C., up to 100 mA / 30 V, ~30 Ω
internal resistance. Circuit opens for 2-3 seconds upon alarm.
3 3 3 3 . INSTALLATION
. INSTALLATION
. INSTALLATION
. INSTALLATION
3.1 General Guidelines
A. Microwave radiation passes through glass and non-metallic
walls. Be sure, therefore, to select the correct model in
accordance with the room size. This is important to minimize
the effect of movements occuring beyond room limits which
might cause the MW section to trip.
B. Large reflecting objects (especially metals) in the coverage
area can distort the microwave detector's coverage pattern.
DE1833
460
460
460
Figure 3. Maximum
Coverage Pattern
Installation
Instructions
Figure 1. General View
Alarm Indication: Indicator lights RED for about 3 seconds.
Event Counter: Selectable, 1 or 2 motion events
Tamper Contacts: Normally closed, 50 mA resistive / 30 VDC
MOUNTING
Surface or corner, at the height of 1.8 to 2.4 m (6 to 8 ft)
Note: Base allows single-sided corner mount at 45° to wall.
ACCESSORIES:
BR-1: Surface mounted swivel bracket, adjustable 30° down and
45° left/45° right.
BR-2: BR-1 with a corner adapter
BR-3: BR-1 with a ceiling adapter
ENVIRONMENTAL
Operating Temperature: –10°C to 50°C (14°F to 122°F)
Storage Temperature: –20°C to 60°C (–4°F to 140°F)
RFI Protection: Greater than 20 V/m (20 MHz to 1000 MHz)
PHYSICAL
Size (H x W x D): 94.5 x 63.5 x 49.0 mm (3-11/16 x 2-1/2 x 1-15/16")
Weight: Approximately 50 g (1-3/4 oz)
PATENTS
U.S. Patents 5,693,943 and 6,211,522
C. If two Scantronic 460 units are installed in the same room or
on opposite sides of a shared wall, they should not face each
other and must be mounted at least 20 cm (0.6 ft) apart.
Attention! At power up, the detector undergoes a 60-second
stabilization period, indicated by alternate flashing of the red
and green LEDs.
Figure 2. Inside View
1

Advertisement

loading

Summary of Contents for Scantronic 460

  • Page 1 3.1 General Guidelines A. Microwave radiation passes through glass and non-metallic C. If two Scantronic 460 units are installed in the same room or walls. Be sure, therefore, to select the correct model in on opposite sides of a shared wall, they should not face each accordance with the room size.
  • Page 2 3.2 Illustrated Installation Procedure Disassemble unit Open holes in base Mount base Set jumpers as needed 1.8 - 2.4 m (6 - 8 ft) above ground Wire up the terminal block Walk-test the coverage area 4 4 4 4 . SPECIAL COMMENTS .
  • Page 3 4.2 Compliance with Standards turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: This device has been tested and found to comply with the limits for a –...
  • Page 4 Cooper Security Ltd: Security House, Xerox Business Park, Mitcheldean Gloucestershire, GL17 0SZ. Product Support (UK): Tel (09068) 616343. Between 09:00 and 17:30 Monday to Thursday, 09:00 to 17:00 Friday (CALLS CHARGED AT 60p PER MINUTE). Product Support Fax: (01594) 545401 Internet: www.coopersecurity.co.uk  2001 SCANTRONIC 460 DE1833- (REV. 0, 6/01) DE1833...