  • Page 3: Table Of Contents

    8.1.1. Events configuration ....................22 8.1.2. Configuration of General Options................23 8.1.3. Configuration of communications ................24 8.1.4. Status configuration ....................25 8.1.5. Save Changes Menu configuration ................. 25 List of Figures......................26 saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 4: Chapter 1. Introduction

    To provide the user with information to install and use units the saTECH RIO. 1.2. saTECH RIO The saTECH RIO is a unit that interconnection between units for the transmission of Goose message between two extremes. It is designed to ensure certain acquisition times, logic processing, goose dispatches, reception at the other extreme and subsequent processing in under 12 ms.
  • Page 5 Up to 144 digital outputs per electromechanical relay  5000 Vrms isolation voltage  Cut out capacity of 500 mA at 125 Vdc  Hardware failure output  Plug-in terminals with bracket. saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 6 Dielectric strength. EN 60255-5 (2001). 5kV in inputs/output. 2.5kV in communication and power ports, 1.5kV in Ethernet.  Electrical impulse. EN 60255-5 (2001). 5kV between inputs/outputs and other ports. 2kV in communications. 1.2/50us, three positive and three negative impulses. saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 7: Software Features

    IEC-60870-5-101. Only slave.  Option Modbus RTU (Serial Modbus). Only master.  Option Modbus TCP. master/slave.  Option SAP20. Only slave.  Option IEC-60870-5-104 master/slave  Option IEC-60870-5-103 master  Option IEC-60870-5-101 master. saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 8 The equipment is configured with a user-friendly configuration tool in a graphical environment. Synchronization  IRIG-B-based high-precision synchronization drivers.  Synchronization via network with NTP/SNTP. Cybersecurity  Encrypted password management  Upon request: Customizable firewall integrated into the unit. saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 9: Mechanical Dimensions

    INTRODUCTION 1.5. Mechanical Dimensions The saTECH RIO unit’s main dimensions are shown in all specifications are in millimetres. Figure 1. Dimension drawing. saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 10: Chapter 2. Security Measures

    The use of the unit without proper grounding can cause damage to saTECH RIO, as well as injuries in the event of an accident. Never connect or disconnect a cable and/or connector to/from a saTECH RIO during normal operation.
  • Page 11: Chapter 3. Reception

    2. Visually inspect for any possible damage suffered during transport. (If necessary, contact the supplier). 3. If the saTECH RIO is to be stored before installation, it should be stored in the original packaging in a clean and dry place.
  • Page 12: Figure 3. Front View Of Satech Rio

    Figure 3. Front view of saTECH RIO. 6. Check that the LEDs are working by pressing TEST LED 7. Make sure the software is as requested. (If not, please contact the supplier.) saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 13: Chapter 4. Installation

    4.1. Assembly The saTECH RIO is ready for mounting in a 19” rack. This is done using 4 sets of M6 screws, plastic washers and M6 cage nuts, which are to be assembled as shown in the following diagram.
  • Page 14: Chapter 5. Front

    FRONT Chapter 5. Front The main elements present in the front of the unit are described below: KEYPAD DISPLAY MATRIX MAINTENANCE ETHERNET SERIAL PORT PORTS INDICATORS INDICATORS Figure 5. Description of front.. saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 15: Chapter 6. Wiring

    14 (2.5 mm2) cable of more than 2m in length. The cable must support a 90° C working temperature. The unit’s grounding must be connected before any other of the unit’s terminals and, in the event of uninstalling the unit, must be the last to be withdrawn. saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 16: Power Supply Terminal

    6.3. Communications 6.3.1. Connections on the unit’s front panel The front of the saTECH RIO is equipped with a connector with 2 USB ports and an Ethernet port with an RJ45 terminal and a mini-USB port for diagnostic and maintenance tasks.
  • Page 17: Ethernet Ports

    If using cable ties, make sure not to overtighten. Failure to follow these recommendations may result in internal damage not visible to the naked eye which hinders or impedes communications. saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 18: Serial Ports

    Nine-wire cable with DB-9 male connectors is to be used. The following table shows the connector pins of the DB-9 female connectors available in saTECH BCU. Pin nº. RS-232 RS-485 (4w) RS-485 (2w) TD+/RD+ TD-/RD- saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 19: Dc Digital And Analogue Capture Inputs/Outputs

    Figure 9. 32 opto isolated digital input modules with independent common each 8 inputs. Figure 10. 16 electromechanical relay digital output modules Figure 11. 16 opto isolated digital input modules with independent common each 8 inputs, plus 8 electromechanical relay digital outputs. saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 20: Chapter 7. Software

    Chapter 7. Software 7.1. Architecture The saTECH RIO software is based on a modular architecture that allows the running of those software modules that are necessary for compliance with the requirements of a remote control unit in a specific application. This enables the hardware resources to be adjusted to the application’s software requirements.
  • Page 21: Figure 13. Functional Diagram

    Local LCD display management module  NTP or IRIG-B synchronization management module.  Network status and gateway failover monitoring module.  System LEDs processing module Descriptive diagram of functionality: Figure 13. Functional diagram. saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 22: Chapter 8. The Unit's Visual Indicators

    Each of the above options will enable the configuration or display of the different options to be displayed/configured. 8.1.1. Events configuration Enables the viewing of the events on the screen, and the resetting of the events if the list is to be deleted. Figure 16. Events menu saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 23: Configuration Of General Options

    (time, date, passwords, display, etc.). The screen structure is as shown in the following scheme, where green represents the editable options. Figure 17. General menu Figure 18. General menu (continue) saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 24: Configuration Of Communications

    8.1.3. Configuration of communications Enables the configuration of the unit’s serial and Ethernet communications. The menu allows the parameters marked in green in the following screenshot to be changed: Figure 19. Communications menu saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 25: Status Configuration

    Enables the changes effected in the unit to be saved and sent to the same. In order to send the changes, the administration password will be requested. Figure 21. Save changes menu saTECH RIO | User´s Manual | Rev. 1.0...
  • Page 26: List Of Figures

    List of Figures Figure 1. Dimension drawing....................9 Figure 2. Connection unit power supply................11 Figure 3. Front view of saTECH RIO................... 12 Figure 4. Mounting in 19” rack.................... 13 Figure 5. Description of front....................14 Figure 6.