T a b l e o f C o n t e n t s 1 INTRODUCTION................4 1.1 About this Document ..............4 1.2 Revision Information..............4 1.3 Other ACM Manuals..............4 1.4 DNV Type Approval Regulations..........4 1.5 ACM Test Reports ..............4 2 ACM SYSTEM OVERVEIW...............
INTRODUCTION 1.1 About this Document The scope of this document is to provide system description for the VINGTOR ACM Telephone System (ACM-M-A-V2). The document consists of the following main parts: System overview Installation guide Programming guide User guide Specification Programming and Cable Reference List 1.2 Revision Information...
ACM SYSTEM OVERVEIW 2.1 VINGTOR ACM Solutions The VINGTOR ACM Telephone System (ACM-M-A-V2) is part of the well known VINGTOR ACM solutions. The complete set of ACM system solutions are: VINGTOR ACM Analogue Telephone System (ACM-M-A-V2) VINGTOR ACM Standard Integrated System...
2.2 ACM Telephone System The VINGTOR ACM Telephone System (ACM-M-A-V2) is a PABX made for marine environment. The system has an extensive and programmable set of features supporting all key PABX functions. The...
ACM-M-A-V2 rack and supports a wide range of PABX and emergency communication features. The exchange has 7 slot positions for feature cards. In an ACM-M-A-V2 rack the AlphaCom E7 is equipped with one main processor board (AMC-IP), 1 ASLT line board for 5 intercom stations and PA interface, and up to 5 subscriber line boards (ATLB12) for analogue telephones.
Relay box for Signal Unit, Watertight IRR-3 Telephone Tone Caller, indoor HB-90 Telephone Tone, Watertight HB-105 Other optional equipment related to ACM-M-A-V2 TYPE ORDER No. Billing, 2, 4, 8, 16 or 32 external trunks 100 9647 902 - 932 Analogue Media Gateway -4FXO...
HW INSTALLATION GUIDE 3.1 System Rack Mounting The ACM-M-A-V2 system rack is made for wall mounting. Mount the cabinet at a convenient height, bottom about 1.2 m above the floor. Make sure there is enough space around the rack for connection and min.
AC fail X3 circuit breaker if this backup power is used DC fail The ACM-M-A-V2 rack will consume max. 150 Watts. The 230 V power cable must have a minimum dimension of 1.5 mm and the 24 V cable should be 2.5 mm SYSTEM fail The 230 VAC mains outlet X7 is used for service purposes.
Figure 8 Subscriber line interface twisted pairs and an outer braided tinned copper screen. The screen must be interconnected in junction boxes and grounded to a common ground point in the ACM-M-A-V2 system rack only. Physical numbers Default call no.
Preferred solution for analogue ACM exchanges with one-way Switch audio announcements (AMC-M-A). Alternative 2 – connect to X7, Talk-Back. Normally not suited for ACM-M-A-V2 unless if ACM must have highest priority. Preferred solution for digital ACM exchanges with two-way audio. 3.7.1 PA amplifier with chime, without monitor...
Set switch S9 to ON to simulate audio-out load when monitor station is missing Set switch S10 to ON to simulate audio-in load when monitor station is missing Leave switches S7, S8 and S17 OFF. Set volume control RP3, OUT2, to mid pos. This must be readjusted to 1±0.5 Vrms during live test Set switch S1 in Potent.
PROGRAMMING AND CABLE REFERENCE LIST The ACM-M-A-V2 programming and cable reference list consists of a set of tables summarizing the main information needed to program an ACM-M-A-V2 exchange for a vessel. The standard programming is documented in a Microsoft Excel Spreadsheet.
COS 16 Includes all services. Default for SuperUser 4.1.3 Terminal connections The LCM module number. ACM-M-A-V2 has only one module. Large exchanges (ACM-48, ACM- 144) may have more than 60 subscribers and need for two or more modules. Station terminal number The A,B,C and D wires are the 4 wires used towards stations.
4.2 Integrated PA Interface By default the system is programmed to support emergency PA announcements (ALL CALL) initiated from analogue telephones with group access level = 2. INTEGRATED PA INTERFACE Signal direction Type Terminal Info ACM to SPA Audio 0dB LCM, J15, OUT2 Audio 8A/B for PA monitor ACM to SPA...
When a new exchange shall be configured, the exchange is given a default working factory setting suited for ACM-M-A-V2. The operator can then modify the settings. AlphaPro is an off-line tool. This means that it is possible to enter all parameters without the necessity of being connected to the exchange.
5.1.1 Connect to AlphaWeb Connect the PC Ethernet port to the LAN port (Eth0) on the ACM-E7 backplane. Use your web-browser to connect to the AlphaWeb. Enter http://169.254.1.5 (default address) in the address field Connection with the ACM is verified by the text: [Login] Secure AlphaWeb (https) [Login] Unsecure AlphaWeb (http) Click on [Login] for unsecure (http) unless encrypted access to...
5.2 AlphaPro, Getting Started 5.2.1 PC setup Start up the computer Download the latest AlphaPro version from www.zenitel.com insert the CD-ROM with the AlphaPro installation Select and run file installalphapro.exe Follow the instructions on the screen You can safely answer “YES” to all questions 5.2.2 Insert the HW dongle Insert the hardware dongle in the PC’s parallel port or USB port depending on the dongle type.
5.2.5 Data communication In order to establish communication between the PC and the exchange, the PC must be connected to the ACM exchange. Connect the PC to the Eth0 port in the ACM exchange When the PC is connected to the ACM, the AlphaPro communication program can be opened.
PROGRAMMING GUIDE 6.1 Programming Overview The main steps for programming of a ACM-M-A-V2 system are: Perform cold start Configure IP address Enter license key Configure general user settings Configure interface to PA Configure external communication A complete programming procedure is described in the System Maintenance Manual A100K 10338.
6.3 Configure IP Address To connect the AlphaCom E to your IP network, you need to enter the IP settings for the Ethernet ports and IP route entries according to the network. See Chapter 4.3 ACM Programming and Cable Reference List for IP settings to use.
Press the Insert new license key button to install this license. The license configuration is shown on top of the page. Note! The ACM-M-A-V2 requires IP station license and SIP trunk licenses for the number of IP stations and analogue telephone trunks the exchange shall support.
6.5 Configure User Settings This chapter describes how to program the system user and station directory in order to comply with marine requirement for emergency two way communication. The chapter is divided in the following parts: General user settings Program different class of service for users Program call priority Before you will be able to program the user and station directory, the Program and Cable Reference List must have been filled in.
Page 26
with 1, 2, 3, 4 or 5. Numbers with first digit 6-9 are reserved for functions. If these numbers should be used, the corresponding function code must be changed. ‘Display Text’ is the station ID text shown in the called station’s display and system logs as well as for billing and DECT display.
The RCO is used to signal PTT and muting of GA during emergency PA to the PA system. Press User and Stations icon Select the subscriber position used as interface to the PA system In ACM-M-A-V2 physical no. 8 is used. Press Events Press Insert Select Event Type to Audio...
USER GUIDE 7.1 Overview The functions and codes are the same for all analogue telephones. Some analogue telephones have special feature keys which are needed for some of the described functions. 7.2 Basic Functions 7.2.1 Establish internal telephone call Lift handset Dial number of desired phone Call is set up when remote phone handset is lifted Replace handset to end the conversation...
7.3 Other PBX Functions The system supports a set of other PBX functions. The main supported PBX functions are: 7.3.1 Inquiry call Only for telephones with R button. Press R+2 during conversation Dial number of desired phone Call is set up when handset on remote enquired phone is lifted CALLER OWN REMOTE Press R+2 to toggle between the phones...
Page 30
SPESIFICATIONS 600W x 600H x 350D Dimension (mm) 45 kg Weight Wall mounted Mounting 0 - 55°C (recommended 18 - 25°C) Temperature range 230 VAC mains; max. power 150 W Power 24 VDC emergency; max power 150 W Automatic switchover between mains and emergency IP 20 IP class...
230 VAC mains 230 VAC 24 VDC AC fail DC fail SYSTEM fail Line Card 1 Cabinet earth SERVICE OUTLET 230 VAC Ground Bar Figure 27 Internal wiring in ACM-M-A-V2 A100K 10430 v.1.0 ACM Telephone System – AMC-M-A Page 31...
Page 32
www.vingtor.com Zenitel Norway AS P.O.Box 4498 Nydalen NO-0403 OSLO Norway DOC NO A100K10430 v.1.0 support@vingtor.com STENTOFON and VINGTOR products are developed and marketed by Zenitel Norway AS. The company’s Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001:2002. Zenitel Norway AS Page 32 ACM Telephone System –...