Longtime LIV-10 User Manual

Pure sine wave power inverter

Advertisement

Quick Links

 
DC AC POWER INVERTER 
 
 
 
 
 
 
 
 
 
 
 
 
 
LIV ‐ 10 / LIV‐20 / LIV‐30 
User Manual 
 
 
 
 
 
 
 
 

Advertisement

Table of Contents
loading

Summary of Contents for Longtime LIV-10

  • Page 1   DC AC POWER INVERTER                            LIV ‐ 10 / LIV‐20 / LIV‐30  User Manual                 ...
  • Page 2 Save This Manual      Please  read  this  manual  carefully  prior  to  storage,  installation,  wiring,  operation  and    maintenance of the Power Inverter.          This manual contains important instructions and warnings that you should follow during the    storage,  installation,  wiring,  operation  and  maintenance  of  the  Power  Inverter.  Failure  to    follow these instructions and warnings will void the warranty.        Please note that only qualified and trained technician can do installation, wiring, operation ...
  • Page 3: Table Of Contents

    Contents    Section 1: Safety Instruction ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 1                    1‐1 Notes on Using the Instruction Manual ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 1                    1‐2 General Safety Instruction ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 1                          1‐2‐1 Installation and Wiring Compliance ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 1                          1‐2‐2 Preventing Electrical Shock ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 1   ...
  • Page 4                   4‐5 Cooling By Forced Air Fan Ventilation ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 9                    4‐6 Precautions When Working with Batteries ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 9                    4‐7 DC Side Connection ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 9  Section 5: Operation ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 11                    5‐1 Start‐Up ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 11   ...
  • Page 5: Section 1: Safety Instruction

    Section 1: Safety Instruction    1‐1 Notes on Using the Instruction Manual    Failure to observe this instruction can cause material damage and impair the function of    the device.  Relating to a danger from electrical current or voltage. Failure to observe this instruction    can cause material damage and personal injury and impair the function of the device.    1‐2 General Safety Instruction    1‐2‐1 Installation and Wiring Compliance    Installation and wiring must comply with the local and national electrical codes and must be done  by a certified electrician.    1‐2‐2 Preventing Electrical Shock    Always  connect  the  grounding  connection  on  the  POWER  INVERTER  to  the  appropriate  grounding system.  Disconnect all AC and DC side connections before working on any circuits associated with the  POWER INVERTER. Pressing the ON / OFF button on the POWER INVERTER to OFF position  may not entirely remove dangerous voltages.  Be careful when touching bare terminals of capacitors. The capacitors may retain high lethal  voltages even after the power has been removed. Discharge the capacitors before working  on the circuits.    1‐2‐3 Installation Environment ...
  • Page 6: 1-2-5 Precaution When Working With Batteries

    fuel tanks, battery compartments.    1‐2‐5 Precaution when Working with Batteries    Batteries contain very corrosive diluted sulphuric acid as electrolyte. Precautions should be  taken to prevent contact with skin, eyes or clothing.  Batteries generate hydrogen and oxygen during charging resulting in evolution of explosive  gas  mixture.  Care  should  be  taken  to  ventilate  the  battery  are  and  follow  the  battery  manufacturer recommendation.  Never smoke or allow a spark or flame near the batteries.  Use caution to reduce the risk of dropping a metal tool on the battery. It could spark or short  circuit the battery or other electrical parts and could cause an explosion.  Remove  metal  items  like  rings,  bracelets  and  watches  when  working  with  batteries.  The  batteries can produce a short circuit current high enough to weld a ring or the like to metal  and thus cause a severe burn. ...
  • Page 7: 1-3-3 Preventing Dc Input Over Voltage

    Do not directly connect to the hot side of the POWER INVERTER to the two hot legs of the  115  /  230V  AC  electrical  breaker  panel  /  load  centre  where  multi‐wire  (common  neutral)  branch  circuit  wiring  method  is  used  for  distributing  of  AC  Power.  This  may  lead  to  overloading / overheating of the neutral conductor and is a risk of fire.   A  split  phase  transformer  (Isolated  or  Auto  transformer)  of  suitable  wattage  rating  (25%  more ...
  • Page 8: Section 2: Introduction

    Section 2: Introduction     Thank  you  for  selecting  this  POWER  INVERTER.  It  is  a  state‐of‐the‐art  electronic  POWER  INVERTER that uses the latest technology.    The  LIV  Series  POWER  INVERTER  is  an  advanced  pure  sine  wave  POWER  INVERTER  which  provides  reliable  regulated,  transient‐free  AC  power  to  sensitive  equipment,  ranging  from  computers & telecommunication systems to computerized instrument. ...
  • Page 9: Section 3: Outlook

    Section 3: Outlook     3‐1 Front View      Standard Model      Customized Model    No.  Description  1  Ventilation exit  2  Control buttons  3  LCD display  4  LED indicators  5  Battery N.F.B.  6  AC input N.F.B.  7  AC output N.F.B. (option)    3‐2 Rear View      48VDC Model      125VDC Model  5 ...
  • Page 10: 3-3 Terminal Block Connecting Diagram

    No.  Description  1  Output socket  2  Terminal block  3  RS232  4  Dry contact  5  Ventilation exit  6  Battery terminal    3‐3 Terminal Block Connecting Diagram                                                   ...
  • Page 11: 3-4 Operation Panel

            3‐4 Operation Panel        No.  Description  1  Page up button  2  Menu button  3  ON / OFF button or page down button  4  The green LED is on when connects to AC power  5  The green LED is on when connects to DC power.  6  The red LED is on means bypass mode  7  The green LED is on means inverter mode  8  The green LED is on means loads connected (>5%)  9  The red LED is on means inverter fault  7 ...
  • Page 12: Section 4: Installation

    Section 4: Installation     4‐1 Unpacking and Inspection      Unpack the packaging and check the package contents. The shipping package contains:    A POWER INVERTER  A user manual    Inspect  the  appearance  of  the  POWER  INVERTER  to  see  if  there  is  any  damage  during  transportation. Do not turn on the unit and notify the carrier and dealer immediately if there is  any damage or lacking of some parts.    4‐2 Installation and Wiring Compliance    Installation and wiring must comply with the local and the national electrical codes and must  be done by a certified electrician.  The  DC  input  positive  and  negative  terminals  are  isolated  from  the  chassis.  Similarly,  the  neutral ...
  • Page 13: 4-5 Cooling By Forced Air Fan Ventilation

    4‐5 Cooling By Forced Air Fan Ventilation    The  POWER  INVERTER  produces  heat  when  operating.  The  amount  of  heat  produced  is  proportional  to  the  amount  of  power  supplied  by  the  POWER  INVERTER.  A  DC  fan  is  used  to  provide  forced  air  cooling  of  this  POWER  INVERTER.  The  fan  is  thermostatically  controlled  and  will be switched on only if the temperature of certain hot spot inside the POWER INVERTER rises ...
  • Page 14 Failure  to  place  a  fuse  on  ”+”  cables  running  between  the  POWER  INVERTER  and    battery may cause Barrage to the POWER INVERTER and wire void warring.  The installation of a fuse must be on positive cable. Failure to place a fuse on cables  running  between  the  POWER  INVERTER  and  battery  may  cause  damage  to  the    POWER INVERTER and will void warranty.            10 ...
  • Page 15: Section 5: Operation

    Section 5: Operation     5‐1 Start‐Up    Press ON/OFF button lasts for 2 seconds  To  avoid  touch  error  or  push  button  fault,  be  sure  to  press  ON  /  OFF  button  lasts  for  2  seconds, till the LCD display “WELCOME TO POWER INVERTER WORLD”    5‐2 Shutdown    Press “ON/OFF” button lasts for 2 seconds  To avoid touch error or push button fault, be sure to press the button lasting for 2seconds.    5‐3 System Test    LCD displays ”POWER INVERTER LOOP CHECK”.    Test  before  the  equipment  operates.  If  DC  voltage  is  too  low,  overheat  or  other  abnormal  status, the panel will have fault display, the unit will auto shutdown 5 seconds later. ...
  • Page 16: Section 6: Troubleshooting

    Section 6: Troubleshooting     SYMPTOM  POSSIBLE CAUSE  REMEDY  When switching on,  There is no voltage at the  1. Check the continuity of the battery  the AC INPUT Green  DC input terminal  input circuit.  LED does not light.  2. Check that the battery fuse is intact.  Buzzer is off. There is  Replace if blown.  no AC Voltage  3. Check that all connections in the battery  input circuit are tight.  LCD displays “DC  DC input voltage is less  1. Use true RMS reading meter to  Volt too low, can’t  than the lowest working  measure if the DC Voltage reaches to  turn on”, cannot  voltage  the lowest working voltage. (48VDC  power on.  System: 42Vdc, 125VDC System:  105Vdc)  2. Verify if DC Cable is loose.  3. Verify if DC Voltage (48V / 125V DC)  comply to the POWER INVERTER spec.  “FAULT” LED lights  Permanent shut down of  1. Reduce the load. The load is not  on, buzzer alarms or  the AC output due to  suitable as it requires higher power to  LCD displays ...
  • Page 17: Section 7: Communication Port

    Section 7: Communication Port     7‐1 Dry Contact          7‐2 RS232  R S- 232 PI NS A SSI GNM ENT : R S- 232 PI NS A SSI GNM ENT : R S- 232 PI NS A SSI GNM ENT : R S- 232 PI NS A SSI GNM ENT : R S- 232 PI NS A SSI GNM ENT : R S- 232 PI NS A SSI GNM ENT :...
  • Page 18: Section 8: Warranty

    Section 8: Warranty     Seller  warrants  this  product  for  a  period  of  1  YEAR  from  the  date  of  shipment,  if  used  in  accordance  with  all  applicable  instruction,  to  be  free  from  original  defects  in  material  and  workmanship  within  the  warranty  period.  If  the  product  has  any  failure  problem  within  the  warranty ...
  • Page 19: Section 9: Specification

    Section 9: Specification     Model  LIV‐10  LIV‐20  LIV‐30  Rating  1KVA  2KVA  3KVA  Max.  48Vdc  19A  38A  57A  Current  125Vdc  7.6A  15A  22A  48VDC (42~64VDC)  Voltage Range  125VDC (105~160VDC)  DC Input  Option: 110VDC (95~144VDC)  Connections  Hard‐wired Connection  Efficiency  > 85% (Full Load)  Nominal Voltage  110Vac or 230Vac ±25%  Utility  Power  Frequency  50 or 60Hz ±3Hz  (Bypass)  Protection  Electronic circuits & AC circuit breaker  Output Power  800W ...
  • Page 20: Section 10: Wiring Diagram

    Section 10: Wiring Diagram             16 ...

This manual is also suitable for:

Liv-20Liv-30

Table of Contents