PRO-60/70X5FD
Adjustment point
1G3Y****
MG3G****
MG3B***
MG3R****
MG3Y****
Point 2
LEV20108
GCC2****
1G2G****
1G2B***
1G2R****
1G2Y****
MG2G****
MG2B***
MG2R****
MG2Y****
Point 1
LEV10048
GCC1****
1G1G****
1G1B***
1G1R****
1G1Y****
MG1G****
MG1B***
MG1R****
MG1Y****
Black brightness measurement
GCP00000
Gamma adjustment value storage
GCST0001
Writing
MSET0030
10. Key writing
10.1. MAC key writing (MAIN PWB: QPWBXF733WJN2)
1. Write the MAC key data on IC8455 mounted on the main PWB.
2. Carry out thorough data management to avoid redundant writing of data.
If the IC where data is written is damaged, replace the PWB since only the IC cannot be changed.
10.2. NETFLIX/WMDRM key writing (MAIN PWB: QPWBXF733WJN2)
1. Write the NETFLIX/WMDRM key data on IC8401 mounted on the main PWB.
2. Carry out thorough data management to avoid redundant writing of data.
If the IC where data is written is damaged, replace the PWB since only the IC cannot be changed.
10.3. Wide Vine key writing (MAIN PWB: QPWBXF733WJN2)
1. Write the wide vine key data on IC8401 mounted on the main PWB.
2. Carry out thorough data management to avoid redundant writing of data.
If the IC where data is written is damaged, replace the PWB since only the IC cannot be changed.
NOTE: For EDID of the analog RGB (DSUB 15pin), write the data on the process menu just like HDMI.
Adjustment conditions
Adjustment procedure
[Adjustment value]
* According to the "Standard settings" submitted by the Technical Department
[PRO-60X5FD] X5FD model teaching set
[Adjustment standard value]
Measuring instrument: [Minolta CA-210] Technical measuring instrument
Level
Reference value
X=0.3127
Point 6
972
y=0.3290
X=0.3127
Point 5
916
y=0.3290
X=0.3127
Point 4
768
y=0.3290
X=0.3127
Point 3
600
y=0.3290
X=0.3127
Point 2
432
y=0.3290
X=0.3127
Point 1
192
y=0.3290
Remarks
Setting conditions for inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Active Backlight: OFF
Aging Time: Min. 60 minutes
5 – 14
Adjustment spec
Inspection spec
±0.0010
±0.0020
±0.0010
±0.0020
±0.0015
±0.0030
±0.0020
±0.0040
±0.0030
±0.0060
±0.004
±0.0080