6. Controls

1
'ext.' button (= 'externally armed')
2
'int.' button (= 'internally armed')
3
LED
4
'unscharf' button (= 'disarmed')
5
Opening to attach to a key ring
The cover of the battery compartment is
located at the rear side of the remote
control.

a) Normal button functions

'unscharf' (disarm) button (
• This button is used to 'disarm' the alarm base station.
All sensors except the smoke detectors are deactivated. You can move
around your house freely without setting off the alarm.
An alarm is always triggered when a smoke detector or a glass
break sensor (terminal KL1, NO contact required) connected to
the 'FAZ-TF' door/window sensor is triggered.
• A triggered alarm can be stopped by pressing the 'unscharf' (disarm) button
4
(
). The alarm memory is deleted when this button is pressed again.
'int.' button (
• The 'internally armed' mode of the alarm base station is set. This is used
to protect the outer shell, for instance, for protection inside a house at night.
One can move inside the house freely. Ensure that the sensors are
configured accordingly (internal/external sensor).
• The activation is rejected when the button is pressed for the first time if
there is a fault or a magnetic contact is not closed (for instance, a window
is open). The 'internally armed' mode is forced to be set when the button
is pressed again.