Do you have a question about the Juniper EX and is the answer not in the manual?
Questions and answers
Summary of Contents for EG Juniper EX
Page 1
Monitoring Juniper EX Switch eG Enterprise v6...
Page 2
The information contained in this document is confidential and subject to change without notice. No part of this document may be reproduced or disclosed to others without the prior permission of eG Innovations Inc. eG Innovations Inc. makes no warranty of any kind with regard to the software and documentation, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
T able of Contents MONITORING JUNIPER EX SWITCH ............................. 1 The Operating System Layer ............................2 1.1.1 CPU Utilization Test ..............................2 1.1.2 Uptime Test ................................4 1.1.3 Memory Test ................................6 1.1.4 Temperature Test ..............................8 1.1.5 Temperature Traps Test ............................9 1.1.6...
If this switch, which assures service operators of continuous network connectivity and secure transaction of business, starts malfunctioning suddenly, the connection to mission-critical services will be lost, thereby causing irreparable damage to reputation and revenue. It is therefore imperative that the operations of the Juniper Ex Switch are monitored 24 x 7.
This layer tracks the current CPU usage, memory, temperature and the uptime of each hardware component of the Juniper EX Switch. Besides this, this layer helps you in identifying the number of trap messages that were sent by the switch for failures of the power supply units , fans and abnormal deduction in temperature of the hardware components.
Page 6
SNMP data traffic related to the Juniper EX Switch over TCP (and not UDP). For this, set the DATA OVER TCP flag to By default, this flag is set to...
CPU resources at its maximum. 1.1.2 Uptime Test This test measures the uptime of each hardware component of the Juniper EX Switch and reports administrators if any hardware component has been running without reboot for a longer period of time. Purpose...
Page 8
Juniper EX Switch over TCP (and not UDP). For this, set the DATA OVER TCP flag to By default, this flag is set to Outputs of the One set of results for each hardware component of the Juniper EX Switch that is to be monitored test Measurements...
1.1.3 Memory Test This test reports the total memory allocated to each hardware component of the target Juniper EX Switch. Using this test, you can monitor the buffer memory utilization and heap memory utilization of each hardware component. This way, you can identify the hardware component that is running short of memory.
Page 10
Juniper EX Switch over TCP (and not UDP). For this, set the DATA OVER TCP flag to By default, this flag is set to Outputs of the One set of results for each hardware component of the target Juniper EX Switch that is to be test monitored...
1.1.4 Temperature Test This test monitors the temperature of each hardware component of the target Juniper EX switch and alerts if any abnormalities are detected. Purpose Monitors the temperature of each hardware component of the target Juniper EX switch and...
Temperature fluctuation of hardware components, if not promptly detected and resolved, can prove to be fatal to the availability and overall health of a Juniper EX Switch. This test intercepts the temperature traps sent by the hardware components of the switch, extracts information related to temperature errors/failures from the traps, and reports the...
Page 13
Intercepts the temperature traps sent by the hardware components of the switch, extracts information related to temperature errors/failures from the traps, and reports the count of these trap messages to the eG manager Target of the A Juniper EX Switch...
Juniper EX Switch. 1.1.6 Power Supplies Test The chassis of the Juniper EX Switch is a rigid sheet-metal structure that houses the hardware components. The field-replaceable units (FRUs) in the EX series switches are: Power supply ...
Page 15
Abnormal power fluctuation to the hardware components often lead to the malfunctioning of the Juniper EX Switch which when left unnoticed can prove to be fatal to the availability and overall health. This test intercepts the traps sent by the switch, extracts information related to power supply failures from the traps, and reports the count of these trap messages to the eG manager.
Page 16
Outputs of the One set of results for each type of event that occurred on the target Juniper EX Switch test Measurements Measurement Measurement...
This test intercepts the fan failure traps sent by the switch, extracts relevant information related to the failure from the traps, and reports the count of these trap messages to the eG manager. This information enables administrators to detect the fan failures if any, understand the nature of these failures, and accordingly decide on the remedial measures.
Page 18
Outputs of the One set of results for each type of failure event that occurred on the target Juniper EX Switch test Measurements Measurement made by the...
Juniper EX Switch. 1.2 The JEX Service Layer This layer tracks the CPU mode of each routing engine available in the Juniper EX Switch. Figure 3: The tests mapped to the JEX Service layer 1.2.1 Switch Details Test The Routing Engine runs the Junos OS.
Page 20
By default, the eG agent does not encrypt SNMP requests. Accordingly, the ENCRYPTFLAG is set to NO by default. To ensure that SNMP requests sent by the eG agent are encrypted, select the YES option.
Page 21
SNMP data traffic related to the Juniper EX Switch over TCP (and not UDP). For this, set the DATA OVER TCP flag to By default, this flag is set to...
Enterprise suite of products, refer to the user manuals. We will be adding new measurement capabilities into the future versions of the eG Enterprise suite. If you can identify new capabilities that you would like us to incorporate in the eG Enterprise suite of products, please contact support@eginnovations.com.