  • Page 1 903-CIS0230-A Installation instruction 0.9m Antenna LEAX Arkivator Telecom disclaims any liability for the results of improper or unsafe installation, inspection, maintenance, or removal practices. Torsgatan 5B Telephone: +46 31 386 11 00 SE-411 04 GÖTEBORG customer.lat@leax.com SWEDEN www.leax.com...
  • Page 2: Tools Required

    Tools required Allen key 3 mm; for M4.  Combination wrench (ring/open jaw) for Hex 15 & 16 mm; for M10.  Socket wrench and sockets for Hex 15 & 16mm; for M10.  Tool for torque levels; 2.6 Nm and 49 Nm. ...
  • Page 3 3(8)
  • Page 4 Assembly Step 1 – Spherical radome (26-38GHz only) For frequencies 6-23GHz, skip Step 1 and go directly to Step 2. For frequencies 26-38GHz, proceed with Step 1a-1d. Mount 7pcs M4 Clip ( 1 ) to Reflector ( 2 ). Position Spherical radom ( 3 ) with convex side pointing downward. Place Reflector ( 2 ) onto Spherical radom ( 3 ) and align the edge holes on both parts with each other.
  • Page 5 Step 3 – Antenna support Mount Pivot bracket ( 5 ) to Antenna ( 6 ) using 1pcs M10x40 screw ( 7 ) and 2pcs M10x30 screw ( 8 ). Fit screws finger tight. Mount 2pcs M10 link screw ( 9 ) to Pivot bracket ( 5 ) using 1+1pcs M10x30 screw ( 10 ). Fit screws loosely. Mount 4pcs M10x120 screw ( 11 ) to Pipe attachment bracket ( 12 ).
  • Page 6: Installation

    Installation Left or Right side installation For a left side installation, turn the antenna 180° and mount it upside down. CAUTION: This may require to also rotating the radio interface, see “Assembly: Step 2 – Radio unique installation”. Right side installation Left side installation Tower pipe compatibility: Ø50- Ø120mm Hoist and secure antenna to pipe structure using 2pcs Clamp bracket ( 1 ) and 4pcs M10 flange nut ( 2 ).
  • Page 7: Antenna Alignment

    Antenna alignment Elevation adjustment Ensure 3pcs M10 screw ( 1 ) are slightly loose. Rotate Elevation screw to adjust direction ± 15°. On completion tighten screws to torque of 49Nm ± 5%. Loosen, do not remove Elevation screw Azimuth adjustment Ensure 5pcs M10 nut ( 2 ) ( 3 ) and 2pcs M10 screws ( 4 ) are slightly loose.