LUDLUM MODEL 500-2 PULSER September 2015 Serial Number 206262 and Succeeding Serial Numbers...
Page 2
LUDLUM MODEL 500-2 PULSER September 2015 Serial Number 206262 and Succeeding Serial Numbers...
Page 3
RETURN OF GOODS TO MANUFACTURER If equipment needs to be returned to Ludlum Measurements, Inc. for repair or calibration, please send to the address below. All shipments should include documentation containing return shipping address, customer name, telephone number, description of service requested, and all other necessary information.
Warning Markings and Symbols Replacement of Main Fuse Maintenance and Recalibration Maintenance Recalibration Recycling Parts List Model 500-2 Pulser Pulser Board, Drawing 208 X 61 Readout Board, Drawing 208 X 176 HV Readout Board, Drawing 208 X 145 Ludlum Measurements, Inc. September 2015...
Page 5
Readout Controller, Drawing 208 x 173 Amplitude Readout Board, Drawing 208 x 17 Wiring Diagram, Drawing 208 X 181 Drawings and Diagrams Ludlum Measurements, Inc. September 2015...
Section 1 Section Introduction he Ludlum Model 500-2 Pulse Generator (Pulser) provides the functions necessary for use in calibrating Ludlum instruments, as well as many other scaler/ratemeter instruments. The adjustable output pulse rate is displayed on a three-digit LED readout.
Model 500-2 Pulser Technical Manual Section 2 Section Specifications and Controls Power: 95-135 Vac, 50/60 Hz at less than 20 volt-amperes Pulse Output: standard connector “C” type (“C” cable is provided) measured by a high-impedance voltmeter up to High Voltage Readout: 1999 volts on the PULSE OUT connector.
Model 500-2 Pulser Technical Manual Section 2 Series “C” to “BNC” and “C” to “MHV” adapters are Accessories: provided. Note If the pulse amplitude from the Pulser exceeds ten times the input sensitivity of the test instrument, double pulsing may occur in the instrument under test.
Section 3 Section Getting Started he Ludlum Model 500-2 Pulser (Pulser) is commonly used to calibrate a variety of radiation detection (survey) equipment to a certain count rate (CPS-counts per second, CPM-counts per minute, KCPM-kilo counts per minute, etc.). This is accomplished by measuring high voltage, determining pulse height threshold, and feeding simulated pulses to an instrument.
Model 500-2 Pulser Technical Manual Section 3 If you are calibrating an instrument with an analog display, you will first want to ensure that the meter movement has proper mechanical zero. Adjustments are typically on the front of the meter bezel and must be made with the instrument power OFF and the instrument in its normal handheld (or “resting”) position.
For more detailed information on electronic calibration of Ludlum Measurements instruments utilizing the Ludlum Model 500-2 Pulser, contact Ludlum Measurements, Inc. Training Department, and/or consult Ludlum Measurements, Inc.
Model 500-2 Pulser Technical Manual Section 3 Determining Dose Rate Conversion The pulser is also frequently used (in accordance with ANSI N323-1997, section 4.2) to determine a conversion constant between count rate and dose rate after an instrument has been calibrated to dose rate (on a range). This conversion constant can then later be used for “Bottom Range”...
Pollution Degree 2 (as defined by IEC 664) Cleaning Instructions and Precautions The Model 500-2 Pulser may be cleaned externally with a damp cloth, using only water as the wetting agent. Do not immerse the instrument in any liquid. Observe the following precautions when cleaning: 1.
Ludlum Measurements, Inc. The Model 500-2 Pulser is marked with the following symbols: ALTERNATING CURRENT (AC) (IEC 417, No,. 5032) - designates an input receptacle that accommodates a power cord intended for connection to AC voltages.
Model 500-2 Pulser Technical Manual Section 4 Caution! Verify instrument voltage input rating before connecting to a power converter. If the wrong power converter is used, the instrument and/or power converter could be damaged. The “crossed-out wheelie bin” symbol notifies the consumer that the product is not to be mixed with unsorted municipal waste when discarding.
Ludlum Measurements, Inc. recommends recalibration at intervals no greater than one year. Check the appropriate regulations to determine required recalibration intervals. Ludlum Measurements offers a full-service repair and calibration department. We not only repair and calibrate our own instruments, but most other manufacturers’ instruments.
Page 17
Every returned instrument must be accompanied by an Instrument Return Form, which can be downloaded from the Ludlum website at www.ludlums.com. Find the form by clicking the “Support” tab and selecting “Repair and Calibration” from the drop-down menu. Then choose the appropriate Repair and Calibration division where you will find a link to the form.
To this end, Ludlum Measurements, Inc. strives to supply the consumer of its goods with information regarding reuse and recycling of the many different types of materials used in its products. With many different agencies –...
Model 500-2 Pulser Technical Manual Section 7 Section Parts List Reference Description Part Number Model 500-2 Pulser UNIT Completely Assembled Model 500-2 Pulser 48-1340 PULSER BOARD W/ BOARD Completely Assembled TEMP. STABLE OSC. Circuit Board 5208-084 (Main Board), Drawing 208 X 61...
Model 500-2 Pulser Technical Manual Section 8 Section Drawings PULSER BOARD W/ TEMP STABLE OSC., Drawing 208 X 61 MODEL 500 MAIN BOARD, COMPONENT OUTLINES, Drawings 208 X 63 and 208 X 63A MODEL 500 READOUT BOARD, Drawing 208 X 176...