Advertisement

Instruction Manual
Shaking Water Bath
Gebr. HAAKE GmbH
Dieselstraße 4
D-76227 Karlsruhe
Tel. +49(0)18050HAAKE
oder+49(0)721 4094-444
Fax +49(0)721 4094-418
E-mail:helpdesk@haake.de
SWB25
Part No. 003-4190
1-1-067-2 / 09.1998
HAAKE (USA)
53 W. Century Road
Paramus, NJ 07652
Tel. 201 265 7865
Fax 201 265 1977
http://www.haake-usa.com
Rheo s.a. ( France)
99 Route de Versailles
91160 Champlan
Tel. +33 1 64 54 0101
Fax +33 1 64 54 0187
http://www.rheo.fr

Advertisement

Table of Contents
loading

Summary of Contents for Haake SWB25

  • Page 1 Instruction Manual Shaking Water Bath SWB25 Part No. 003-4190 1-1-067-2 / 09.1998 Gebr. HAAKE GmbH HAAKE (USA) Rheo s.a. ( France) Dieselstraße 4 53 W. Century Road 99 Route de Versailles D-76227 Karlsruhe Paramus, NJ 07652 91160 Champlan Tel. +49(0)18050HAAKE oder+49(0)721 4094-444 Tel.
  • Page 2: Table Of Contents

    ......Your Contacts at HAAKE ....
  • Page 3 Table of Contents 12. Excess Temperature Protection ....12.1 Excess temperature protection dial ..12.2 Setting the excess temperature ... 13.
  • Page 4: Key To Symbols

    Key to Symbols Key to Symbols 1.1 Symbols used in this manual Warns the user of possible damage to the unit, draws attention to the risk of injury or contains safety notes and warnings. Denotes an important remark. Indicates the next operating step to be carried out what happens as a result thereof.
  • Page 5: Quality Assurance

    Quality Assurance / Your Contacts at HAAKE Quality Assurance Dear customer, HAAKE implements a Quality Management System certified according to EN 29001. This guarantees the presence of organizational structures which are necessary to ensure that our products are devel- oped, manufactured and managed according to our custom- ers expectations.
  • Page 6: Safety Notes

    Repairs, alterations or modifications must only be car- ried out by specialist personnel. Considerable damage can be caused by improper repairs. The HAAKE service department is at your disposal for repair work. Do not operate the unit with wet or oily hands.
  • Page 7 Safety Notes The temperature controlling i.e. immersing of test tubes, Erlenmeyer flasks or similar objects directly within the unit constitutes normal circulator practise. We do not know which substances are contained within these vessels. Many substances are dangerous: inflammable, easily ignited or explosive hazardous to health environmentally unsafe You alone are responsible for the handling of these sub-...
  • Page 8: Unit Description

    Unit Description Unit Description 5.1 Safety features The comprehensive safety system is designed on the princi- ple of the concept of the “single fault” (EN 61010). This as- sumes that two separate faults do not occur simultaneously. This system therefore offers protection against one (single) fault.
  • Page 9: Unpacking / Setting Up

    (Small problems can often be dealt with on the spot). 6.2 Information concerning the CE sign HAAKE circulators and cryostats carry the CE sign which con- firms that they are compatible with the EU guideline 89/336/EEC (electromagnetic compatibility). The tests are car-...
  • Page 10: Contents

    Unpacking / Setting Up 6.3 Contents 1 Base unit with mains cable 1 Moveable platform with 4 rollers 1 Rubber connection piece 1 Instruction manual 1 Warranty card (please fill out and return) 6.4 Ambient conditions according to DIN EN 61010 indoors, max.
  • Page 11: Panel Controls And Indicators

    Panel Controls and Indicators Panel Controls and Indicators É É É É É É É É É É É É É É É É É É Ç Ç Ç Ç Ç 10 12 Main switch Dial for shaking frequency Preset temperature dial Malfunction indicator light Excess temperature dial Changing the value...
  • Page 12: Assembly/Connecting Up

    Assembly/Connecting Up Assembly/Connecting Up 8.1 Connecting the platform to the guide rod Lift left end of the platform (11) until the rubber connection (10) at the bathbottom can be picked up and placed over the pin at the underside of the platform. 8.2 Connecting to a mains socket 230 V The unit should only be connected to a grounded mains sok-...
  • Page 13: Setting Up And Starting

    Setting up and Starting Setting up and starting 9.1 Attaching clamps for vessels to the platform (11) Spring clips can be supplied to secure round vessels, e.g. Erlenmeyer flasks or beakers, to the platform. Maximum clamp number see chapter 11. 9.2 Filling in the bath liquid Liquid level: Can be selected anywhere between 50 and 180 mm (Thus, filling level dependent on objects used in the...
  • Page 14: Operational Safety

    It should especially be ensured that the shaking motor is not blocked due to the choice of unsuitable shaking motor parameters. If the SWB25 is only to be used as a waterbath, the rubber connection piece (10) of the platform (11) should be removed.
  • Page 15: Operating

    Operating 10. Operating 10.1 Switching on Switch the unit on at the mains switch 1. The display 16 briefly shows the device identification ”Sb25”, thereafter the version number of the operating software, e.g. ”1.00” and then the actual shaking fre- quency.
  • Page 16: Heating Control Lamp

    Operating Press the enter button 8. The selected value is stored as new set tempera- ture and activated. The new value is not saved until the Enter button has been pressed. The circulator continues to use the old set value. The display 16 automatically switches back to actual tem- perature display after a short time.
  • Page 17: Adjusting The Shaking Frequency

    Operating 10.6 Adjusting the shaking frequency Only possible in the speed displaying mode (Display 17 ”n” is lit). Press the menu button 7: Small display ”n” blinks. Press the shaking frequency button 2: Displayed shaking frequency in the display. Increase (+) or decrease (–) the value shown in the dis- play with the buttons 6.
  • Page 18: Special Functions

    Operating 11. Special functions 11.1 Adjusting the default values Switch on the unit and press both keys 6 (”–” and ”+”). All adjusted parameters are set back on default values. SOLL = 20.0 C = 20 rpm RTA CT = 0.00 C In display 16 the message”CodE”appears.
  • Page 19: Excess Temperature Protection

    First set the desired set value using keys 6 (+), (–) to exactly 35 C. After the SWB25 has reached this temperature, turn the excess temperature dial 5 backwards very slowly (to the left) until the unit cuts off (acoustic signal, fault message).
  • Page 20: Fault Display

    Fault Display 13. Fault display 13.1 Sensor bath/short circuit At faults of the measured value recognition the message ”AL-F” is shown. The display part ”AL” blinks, the heater is switched off, the shaking process is not interfered as long as the fault is present. When the measured value recognition has regenerated itself the normal operation is contin- ued.
  • Page 21: Special Accessories

    Special Accessories 14. Special Accessories Order No.: Description: Additional information 333-0642 (1) Bath cover, roof shaped, plastic 827-0310 (2) Plastic balls for covering 500 balls sufficient bath, for 0.2 m 000-8581 (3) Cooling coil for tap water cooling 333-0259 (4) Basic rack, without any attachments (with special clamping device for shaking platform)
  • Page 22 Special Accessories Order No.: Description: Additional information 333-0129 (5) Universal basic rack for Can be used only as test tubes normal water bath. 333-0130 (6) 2 Inserts for Per basic rack (4) 86 tubes, 10 mm ø 2 sets (4 pieces) 333-0131 2 Inserts for 46 tubes, 16 mm ø...
  • Page 23 Special Accessories Order No.: Description: Additional information (8) Clamps for flasks/ beakers 000-8732 for 25 ml, flasks/beakers up to 42 mm ø 000-1980 for 50 ml, flasks/beakers up to 51 mm ø 000-1982 for 100 ml, flasks/beakers up to 64 mm ø 000-1990 for 250 ml, flasks/beakers up to 85 mm ø...
  • Page 24: Maximum Clamp Number For The Moveable Platform For

    Maximum Clamp Number 15. Maximum clamp number for the moveable platform for ... 40 x 25 ml ( 000-8732 ) 32 x 50 ml ( 000-1980 ) 18 x 100 ml ( 000-1982 ) 12 x 250 ml ( 000-1990 ) 8 x 500 ml ( 000-1994 ) 5 x 1000 ml ( 000-1995 )
  • Page 25: Technical Specifications

    Technical Specifications 16. Technical Specifications 16.1 Unit Working temperature 25 - 90 C range with tap water cooling 20 - 90 C Temperature Accuracy Heater power 230V 1500 115V 1500 Control type Excess temp. protection Shaking amplitude mm 15 Shaking frequency 20...200 (continuous) Bath opening/depth mm 500 x 300 / 200...