Astra H8295 Installation And Operation Instructions Manual

Brentwood lv 900095-00

Advertisement

Quick Links

Shown with louver kit installed
A French manual is available upon request. Order P/N 900096-00.
Ce manuel d'installation est disponible en francais, simplement en faire
la demande. Numéro de la pièce 900096-00.
THIS UNIT REQUIRES THE INSTALLATION OF A
FINISHING KIT. SEE "PARTS REQUIRED"
SECTION FOR DETAILS
Fireplace, Also For Use In
Manufactured Homes With Solid Fuel Only.
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it is
recommended that this appliance be fi tted with
an adjustable safety gate or barrier screen.
C
US
Shown with clean face kit installed
WARNING
Listed to standards:
ULC-S610 & UL-127
Report # 14-180
EPA Cert. No. 537
P900095-00
INSTALLATION AND

OPERATION INSTRUCTIONS

Brentwood™ LV
EPA Wood-Burning Fireplaces
P/N 900095-00 REV. C 06/2016
MODEL
Brentwood LV
This installation manual will enable you to obtain a safe, effi cient and
dependable installation of your fi replace system. Please read and
understand these instructions before beginning your installation.
Do not alter or modify the fi replace or its components under any circum-
stances. Any modifi cation or alteration of the fi replace system, including
but not limited to the fi replace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
IHP wood-burning fi replaces are designed for use as a supplemental
heater. They are not intended for continuous use as a primary heat
source.
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING
• The fi replace cannot be operated without a door
or fi rescreen. Consult your dealer to select the
correct door or fi rescreen.
• Important! To assure proper alignment of glass
doors: Install this fi replace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
• Install the fi replace only as described in these
instructions.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H8295 and is the answer not in the manual?

Questions and answers

Summary of Contents for Astra H8295

  • Page 1: Operation Instructions

    INSTALLATION AND OPERATION INSTRUCTIONS Brentwood™ LV EPA Wood-Burning Fireplaces P/N 900095-00 REV. C 06/2016 MODEL Brentwood LV This installation manual will enable you to obtain a safe, effi cient and Shown with louver kit installed Shown with clean face kit installed dependable installation of your fi...
  • Page 2: Safety Rules And Specifi Cations For Mobile Or Manufactured Home Installation

    IMPORTANT! GENERAL SAFETY WARNING WARNING PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY Use care when selecting window Always ensure that the air inlet to RULES BEFORE YOUR FIRST FIRE. treatments for windows located the fi replace is free from debris near the fi replace. Avoid using and any other obstructions that combustible flowing window can block the entrance of air.
  • Page 3: Table Of Contents

    CONGRATULATIONS! PARTS REQUIRED Fireplace Model Brentwood LV When you purchased your new wood fi replace, you joined the ranks of thousands of individuals whose answer to their home heating needs refl ects their concern for aesthetics, • .Finishing Kit - Required * effi...
  • Page 4: Operating The Fireplace

    LV fi replace can produce up to 55,000 BTU of OPERATING THE FIREPLACE WARNING heat per hour. However, it will be necessary to reload with wood every one or two hours. Fuel - USE SOLID NATURAL WOOD FUEL This is the least effi cient method of burning the The bottom refractory can be ONLY.
  • Page 5: Refueling For Best Performance

    Creosote may accumulate on the glass door. This C. Wet wood - Wet or tarred wood will smoulder appliances). If your local code requires a smoke method of burning should be used only after and smoke instead of burning properly. Your detector be installed within the same room, you operating the Brentwood LV fi...
  • Page 6: Chimney Maintenance

    NOTE: The use of a fi rewood moisture meter is Chimney Maintenance Dealing With a Chimney Fire recommended to ensure the fi rewood contains less than 20% moisture. Regular chimney inspection and maintenance Regular chimney maintenance and inspection combined with proper operation will prevent can prevent chimney fi...
  • Page 7: Finish Door Casing Care

    Remove ashes only when the fi re is out and the Burning these materials may result in release DOOR ADJUSTMENT ashes are cold (24 to 48 hours after the fi re is of toxic fumes or render the heater ineffective The door may need to be adjusted to be com- out).
  • Page 8: Glass Care - Replacement

    GLASS CARE Gasket Replacement If possible, you should choose a location where the chimney will pass through the house without Remove the door from the unit (see Page 7) Glass Replacement cutting fl oor or roof joists (see fi replace dimen- and lay it on a clean unabrasive surface.
  • Page 9: Installing The Finishing Kits

    INSTALLING THE FINISHING KITS The gravity kit MUST BE used with the trim and the right side frame. This can be diffi cult because these are close together to clean face kit to allow hot air fl ow that allow a good look when using the louver kit. would normally come out of the top louver.
  • Page 10: Framing, Facing And Mantel

    Framing, Facing And Mantel WARNING: THE HEARTH EXTEN- The construction of the framing, facing, and Fireplace SION IS TO BE INSTALLED ONLY mantel must be in accordance with the stan- AS ILLUSTRATED. dards and the following illustrations (Figures 9, 10 and 11): A.
  • Page 11: Fireplace And Framing Dimensions

    Corner Installation Back Wall of Chase/Enclosure Combustion OUTSIDE CHASE Including Finising Materials if any Air Kit 21-1/2” K (allow space when framing) 20-3/8” Rough Framing Face (Unfinished Shown) * Zero Clearance From Back Spacer to Wall FRAMING DIMENSIONS 36-1/4” 921 mm 2 x 3 Combustible materials can NOT be used in the space 40-3/4”...
  • Page 12: Insulated Chase Construction

    Insulated Chase Construction Storm Collar Roof Support Flashing Attic Radiation Shield Floor Ceiling NOTE: It is recommended that the chase Wall walls and fl oor be insulated in the same manner, using the same insulation, as the rest of the building, below the attic. •...
  • Page 13: Facing / Mantel

    Facing Non-Combustible Facing Fireplace Frame Section (Top View) The facing installation method depends on your Drywall fi nishing kit choice. 2 x 3 Min. 1. Facing with the louver kit - The 2x3 framing (51mm x 76mm) must offset to the back by a distance equiva- Spacer lent to the thickness of your facing material Rockboard...
  • Page 14: Hot Air Ducting Installation

    HOT AIR DUCTING INSTALLATION WARNING: The outlet grills Different hot air ducting systems can be installed Outlet Grill should not be installed fac- with the Brentwood™ LV fi replace: ing upward through a fl oor. - Gravity kit Danger of burns can result - Forced air kit if grills in fl...
  • Page 15: Central Forced Air Kit

    The duct system must be installed respecting CENTRAL FORCED AIR KIT (NOT TESTED D) Route the fl exible pipe to the chosen location. the following: The ducting system can be installed either UNDER EPA CERTIFICATION) in an upper room or in a lower room. E) Attach the fl...
  • Page 16: Outside Air Kit

    OUTSIDE AIR KIT - REQUIRED (Included w/fi replace) OUTSIDE CONNECTION During operation, the fi replace requires fresh air for combustion and draws air out of the house. It may starve other fuel burning appliances such as gas or oil furnaces. As well, exhaust blowers may compete for Aluminum Tape air, causing negative pressure in the house, resulting in smoke entering Outside...
  • Page 17: Chimney System

    10. Cut and frame square holes in all fl oors, ceilings, and roof that the THE CHIMNEY SYSTEM chimney will go through to provide a 2” (50 mm) clearance between Chimney Installation Notes the chimney and any combustible materials. Do not fi ll this 2” space 1.
  • Page 18: Chimney Installation Instructions

    CHIMNEY INSTALLATION INSTRUC- Attic Radiation Shield TIONS Attic Radiation ASHT / S2100 Shield HT6103+ / HT6000+ 1. Cut and frame the holes in the ceiling, fl oor Solid Packed Pipe * Flashing and roof where the chimney will pass (see Figure 28).
  • Page 19: Offset Chimney Installation

    After reaching the location requiring the AC * elbow, proceed as follows: Air Cooled Chimney Chimney ASHT / HT6103+ / S-2100+ / HT6000+ Collar DuraTech DTC Chimneys Spacer (built into fl ashing) 1. Install the fi rst elbow; turn it in the required direction.
  • Page 20 Offset Dimensions Total Height Horizontal Offset Chimney Elbow Offset & One Length Between Elbows Two Lengths Between Elbows 6” Height 8” 12” 18” 24” 36” 48” 8” & 48” 12” & 48” 18” & 48” 24” & 48” 36” & 48” 48”...
  • Page 21: Angled Wall Radiation Shield

    ANGLED WALL RADIATION SHIELD When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled fi restop or wall radiation shield must be installed. Only one is required. RSMI45 / 6DTC-S45**) NOTE: 45º angle for Canada only ( Support ACRS In cold climate locations (climates where temperatures will fall below 32°...
  • Page 22: Chimney Support Installation

    CHIMNEY SUPPORT INSTALLATION Universal Roof Support 18” (460 mm) 18” (460 mm) When installing a support, slightly lift the chimney system so the weight will lie on the support, not on the fi replace to reduce expansion noises. This support has three possible uses: 1.
  • Page 23: Masonry Application Instructions

    INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION Follow these steps: 1. Position the fi replace in its location. Temporarily install the ASHT WARNING: Before starting the installation, the masonry chimney elbow on the top of the fi replace and, using a level, mark with an oval must be inspected by a qualifi...
  • Page 24: Installation Accessories

    OPTIONAL INSTALLATION ACCESSORIES Installation Accessories Fireplace Kits Description Cat./Part No. Description Cat./Part No. Blower motor speed control (wall mount), VRUW VRUW Finishing Kits (Required - Order Separately)  BUCFZN Rigid Firescreen Louver kit LOUVRECF  Central Forced Air Kit Accessories Central Forced Air Kit, Central forced air kit including: blower BISFWK-1 Clean face kit...
  • Page 25: Replacement Parts

    REPLACEMENT PARTS - BRENTWOOD™ LV SPECIFICATIONS Brentwood™ LV Cat. No. Model H8295 Brentwood™ LV Item # Description Cat./Part No. Baffl e refractory (2 pieces) PR-ISO2205 EPA Estimated Back refractory PR-SR2996 Model Emission Rate Heat Output Effi ciency Right side refractory...
  • Page 26 REPLACEMENT PARTS - BRENTWOOD™ LV NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 27: Chimney Components Lists

    SECURITY CHIMNEYS™ AND DURAVENT ® - PARTS AND COMPONENTS LISTS The components listed below must be ordered from Security Chimneys International™ or DuraVent ® . Contact your Security Chimneys or DuraVent Distributor or Dealer for ordering information. Security Chimneys International Limited M&G DuraVent 1-800-835-4429 450-973-9999...
  • Page 28 SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS The components listed below must be ordered from Security Chimneys International™. Contact your Security Chimneys Distributor or Dealer for ordering information. Security Chimneys International Limited 450-973-9999 Tubinox® LL Chimney Lining System** 2125 Monterey, Laval, Quebec 1-800-361-4909 (USA) Rigid Stainless Steel Liner For Relining A Masonry Chimney, 6”...
  • Page 29: Warranty

    Innovative Hearth Products ® Astria Brand EPA Wood Burning Fireplace Limited Lifetime Warranty THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria ® Brand EPA Wood Burning Fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture.
  • Page 30: Product Reference Information

    WARRANTY Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order. Your fi replace is covered by a limited warranty. Please read the warranty When ordering repair parts, always give the following information: to be familiar with its coverage.