ELECTRONIC CONTROL UNIT FOR
TWO 12/24 VDC MOTOR
SIRIO 3
12/24
TECHNICAL INSTALLATION MANUAL
FOR AUTOMATIC GATES
WARNING!
Before installing, thoroughly read this manual that is an integral part of this
Kit. BAME S.r.l. declines any responsibilit y in the event current standards in
the country of installation are not complied with
The symbol CE conforms with European Directive R&TTE 99/05CE

Advertisement

Table of Contents
loading

Summary of Contents for Delma SIRIO 3

  • Page 1 ELECTRONIC CONTROL UNIT FOR TWO 12/24 VDC MOTOR SIRIO 3 12/24 TECHNICAL INSTALLATION MANUAL FOR AUTOMATIC GATES WARNING! Before installing, thoroughly read this manual that is an integral part of this Kit. BAME S.r.l. declines any responsibilit y in the event current standards in the country of installation are not complied with The symbol CE conforms with European Directive R&TTE 99/05CE...
  • Page 2: Table Of Contents

    1. INTRODUCTION ................... 3 2. MAIN FEATURES ..................3 3. TECHNICAL SPECIFICATIONS ..............3 4. CONNECTION AND SET UP OF THE CONTROL UNIT......4 GENERAL DIAGRAM OF SETTINGS AND CONNECTIONS ........5 SIMPLIFIED LEARNING PROCEDURE (also see pages 8-10) ......6 PROFESSIONAL LEARNING PROCEDURE (see also pages 8-10)......
  • Page 3: Introduction

    1. INTRODUCTION The universal self-learning SIRIO 3 12-24 control unit has been designed for the automation of an access with 1 or 2 12VDC (24VDC)* motors with or without limit switches. Its innovative self-learning procedure makes for quick and easy installation and its three trimmers permit fine adjustment of all main parameters: force (or speed), pause time, obstacle detection sensitivity and closing delay between the two leaves of the gate when two motors are used.
  • Page 4: Connection And Set Up Of The Control Unit

    MOTOR POWER SUPPLY The control unit adapts itself to run with motors of 12 or 24VDC according to the voltage with which it is powered. The SIRIO 3 12-24 control unit is fitted with a toroidal transformer with a 12VAC secondary.
  • Page 5: General Diagram Of Settings And Connections

    GENERAL DIAGRAM OF SETTINGS AND CONNECTIONS Closing limit switch motor 1 Opening limit switch motor 1 FORCE / STANDBY OBSTACLE SWING Closing limit switch motor 2 SPEED TIME SENSITIVITY DELAY Opening limit switch motor 2 Pushbutton OPEN SIGNALLING LED Pushbutton P2/RADIO DIP SWITCHES Pushbutton...
  • Page 6: Simplified Learning Procedure (Also See Pages 8-10)

    SIMPLIFIED LEARNING PROCEDURE (also see pages 8-10) 1. Verify the initial settings. 2. Program the remote controls (if needed) with the gate stopped (green LED GC turned on) according to the following: a) Press the program button P2/RAD for two seconds: the red LED “RAD” lights up. b) Press the desired button on each transmitter.
  • Page 7: Professional Learning Procedure (See Also Pages 8-10)

    PROFESSIONAL LEARNING PROCEDURE (see also pages 8-10) Using the professional learning procedure the installer can determine: a) the instant in which the opening and closing slow-down starts b) the pedestrian function c) the safety device trigger mode. When the motor and the safety devices are connected, programme the remote controls to be used (see page 8) with the gate stopped (green LED GC turned on).
  • Page 8: Control Unit Operating Logic (Analytic Exam)

    5. CONTROL UNIT OPERATING LOGIC (ANALYTIC EXAM) PROGRAMMING AND CANCELLATION OF THE REMOTE CONTROLS With the receiver built into the control box, BAME rolling code remote Joy and Style can be learned. 5.1.1 Programming Power the control panel and with the automation stopped (green LED GC turned on): •...
  • Page 9: Motor Speed - Trimmer "For

    - when the gate is open the closing commands are inhibited, Using the professional learning, the EDG/PED input can be set as internal photocell: - in closing phase it provokes an inversion of direction when cleared, - in opening phase it provokes a STOP and opening continues when cleared, - when the gate is closed it delays opening until it is cleared, - when the access is open it inhibits the closing commands.
  • Page 10 - opening stops when the limit switches or the obstacle detection system intervenes or when the manoeuvre time has elapsed. If other commands are given during opening they will have no effect. - with the automation stopped and in automatic pause each time the timer re-starts from zero. Once the pause time has elapsed, the closing manoeuvre takes place and the control unit: - carries out a 1 second fixed pre-flash - drives the two motors with a 2...
  • Page 11: Pedestrian Opening" Function

    - if a command is given during closing the control unit commands the complete re-opening - closing stops when the limit switch or the obstacle detecti on system intervenes or when the manoeuvre time has elapsed. “PEDESTRIAN OPENING” FUNCTION The pedestrian function can be assigned with the professional learning to channel 2/3/4 of the remote control. With a “PEDESTRIAN OPENING”...
  • Page 12: Courtesy Light

    5.13 BUFFER BATTERY – SOLAR PANEL MANAGEMENT The SIRIO 3 12-24 control unit is fitted with an automatic 13.7VDC battery charger, for which a 12V battery must be used, even for 24VDC motors. In this case, when there is no mains power the gate will travel at half normal speed and the accessories will be powered at 12VDC.
  • Page 13: Programming Through Gtsystem

    Green led START: - is alight when the OPEN/STEP/STEP (STR) input is closed. - is switched off when the OPEN/STEP/STEP (STR) input is open. 7. PROGRAMMING THROUGH GTSYSTEM The GTSYSTEM is an autonomous multi-functional terminal that can be used on various BAME products both for testing and function modification.
  • Page 14: Troubleshooting

    8. TROUBLESHOOTING PROBLEM PROBABLE CAUSE REMEDY 230 volt mains voltage absent Check master switch Check for any STOP commands Emergency STOP present connected to the STP input. On giving a command with the There is no jumper between the STP If not used, check if there is a remote control or with the key- input and the common.
  • Page 15: Safety Warnings For Installation And Use

    SAFETY WARNINGS FOR INSTALLATION AND USE These warnings are an essential, integral part of the product and must be given to the user. They provide important indications on the installation, use and maintenance and must be read carefully. This form must be preserved and passed on to subsequent users of the system.