Ventry 20EM3550 Owner's Manual

Positive pressure ventilation fans
Hide thumbs Also See for 20EM3550:
Table of Contents

Advertisement

Quick Links

'
O
M
WNER
S
ANUAL
P
P
V
F
OSITIVE
RESSURE
ENTILATION
ANS
Ventry Solutions, Inc.
By
(888) 257-8967
Ventry.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 20EM3550 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ventry 20EM3550

  • Page 1 ’ WNER ANUAL OSITIVE RESSURE ENTILATION Ventry Solutions, Inc. (888) 257-8967 Ventry.com...
  • Page 2 RESSURE ENTILATION Ventry Solutions, Inc. Our experience as volunteer fire fighters, coupled with feedback from fire fighters across the country, has helped make this fan the best on the market. If you have any comments, ideas, observations or creative uses, please contact us by phone, email, mail or fax so that we may continue to improve our product.
  • Page 3: Table Of Contents

    ABLE OF ONTENTS FAN SPECIFICATIONS ........................1 OUT OF THE BOX ...........................3 FAN TRANSPORT ...........................3 One Person Carry ..........................3 Two Person Carry ..........................3 LEG ADJUSTMENT.........................4 How to raise the fan with one person ....................4 Another method of raising the fan, one person ................6 How to lower the fan, one person ....................6 HOW TO USE POSITIVE PRESSURE VENTILATION ..............7 PPV The Basics ..........................7...
  • Page 4 MAINTENANCE ..........................12 Engine Maintenance ........................12 Kevlar & Fiberglass-Coated Propeller ..................12 Frame Maintenance ........................12 Tachometer ..........................12 TROUBLE SHOOTING ........................12 Fan walks during operation ......................12 Leg movement obstructed ......................13 Fan too large to fit compartment ....................13 PARTS ORDERS ..........................
  • Page 5 • (888) 257-8967 Ventry.com Some of the pictures within this V manual show older ENTRY , before the vertical handles and Solid Rubber / Medium ENTRY Flat-Free Wheels with Stair Skids.
  • Page 6: Fan Specifications

    Warranties also differ (see Table 1). noise, emissions, and versatility. à Honda GX200 6.5 hp 5.5 hp ¸ Measurement not yet available. VENTRY SOLUTIONS, INC. • ( 888 ) 257-8967 • ventry.com Pg 1 of 2 20170322 Fan Specs...
  • Page 7 Wheels and Skids. Large Pneumatic Wheels include a vertical handle. Adds 6 lbs. Figure 3. Three wheel choices. Large Small Pneumatic Medium Solid Rubber Flat-Free VENTRY SOLUTIONS, INC. • ( 888 ) 257-8967 • ventry.com Pg 2 of 2 20170322 Fan Specs...
  • Page 8: Out Of The Box

    OSITIVE RESSURE ENTILATION OUT OF THE BOX After unpacking your fan, there are a couple of things you will need to do. First: attach wheel option (if added) per included instructions. Second: add fuel and oil. Oil amounts and specifications are listed in the engine manual under servicing.
  • Page 9: Leg Adjustment

    ENTRY OLUTIONS LEG ADJUSTMENT Please note that these are just suggested ways of raising and lowering the fan. Each firefighter finds a way to set the fan up that works best for them. How to raise the fan with one person Figure 6.
  • Page 10 OSITIVE RESSURE ENTILATION Figure 11. Step 6 Figure 10. Step 5 Step 5: Tighten the leg lock handle on the extended front leg. Step 6: Rock the fan on the two extended legs while adjusting the remaining leg. Figure 12. Step 7 Figure 13.
  • Page 11: Another Method Of Raising The Fan, One Person

    Step 2: Use a rocking motion to lower the legs (Fig 20). Step 3: Tighten all three leg adjustment knobs. Videos showing how to extend and retract the legs on a V can be seen on ventry.com. ENTRY Figure 20. Lowering Fan...
  • Page 12: How To Use Positive Pressure Ventilation

    OSITIVE RESSURE ENTILATION HOW TO USE POSITIVE PRESSURE VENTILATION PPV The Basics Positive pressure ventilation (PPV) is a powerful tool for firefighting but, like a double-edged sword, it can cut both ways. Training and careful planning are essential if PPV is going to work to its full potential.
  • Page 13: Placement

    ENTRY OLUTIONS Placement Avoid operating the fan too close to a structure's opening. Position the fan 8 to 15 feet from an average 3' x 7' door. It is best to err on the side of placing the fan too far from the door to prevent the situation shown in Figure 22.
  • Page 14: Ground Debris Pickup / Maximum Air Volume

    OSITIVE RESSURE ENTILATION The air will take the path of least resistance. If you have a lot of windows and doors open the air will most likely take a path that isn’t the one you want to remove the smoke. Ground Debris Pickup / Maximum Air Volume are designed to run with the legs partially extended.
  • Page 15: Common Questions About Positive Pressure

    ENTRY OLUTIONS COMMON QUESTIONS ABOUT POSITIVE PRESSURE Why positive instead of negative pressure ventilation? Stand on the suction side of a fan -- there's not much happening. Now stand downwind and note the difference. The same thing happens in a structure just as dramatically: with positive pressure, smoke and heat come blasting out of the structure and visibility improves in a matter of seconds.
  • Page 16: Fan Comparison Methods

    OSITIVE RESSURE ENTILATION Positive pressure is also very useful to pressurize areas of a structure to prevent or slow down fire spread into uninvolved areas. We stopped a fire in a 6 unit apartment building using this technique with three fans pressurizing the central foyer. We just opened the door to the apartments that we wanted pressurized.
  • Page 17: Warranty

    Wipe down the frame to remove dirt and grease buildup The rubber leg ends (feet) will need to be inspected for wear. Damage such as missing pieces may allow the fan to walk. Replacements may be obtained through Ventry Solutions or at a local medical supply outlet.
  • Page 18: Leg Movement Obstructed

    Replacement may be necessary. Fan too large to fit compartment Contact Ventry Solutions, Inc. for possible solutions. PARTS ORDERS This is the information we need to make sure that we get correct parts for your fan.
  • Page 19: Parts List For 20-Inch Frame, With And Without Wheel Option

    ENTRY OLUTIONS All nuts, bolts and washers are grade 5 or 8, national fine, zinc coated or better. PARTS LIST FOR 20-INCH FRAME Reference Part Number Number Quantity F-1009 Leg cap, ¾-inch ..................3 F-1004S 20-inch Leg, rear ..................1 F-1001A 20-inch Frame without wheel option ............
  • Page 20: 20-Inch Frame Assembly Diagram

    OSITIVE RESSURE ENTILATION 20 Inch Frame Assembly Diagram...
  • Page 21: Parts List 24-Inch Frame, With And Without Wheel Option

    ENTRY OLUTIONS PARTS LIST 24-INCH FRAME Reference Part Number Number Quantity F-1009 Leg cap, ¾-inch ..................3 F-1004L 24-inch Leg, rear ..................1 F-1001B 24-inch Frame with out wheel option ............1 F-1010 Short foam handle ..................2 F-1018 7/8 Round cap ..................... 2 F-1015 24-inch “seven”...
  • Page 22: 24-Inch Frame Assembly Diagram

    OSITIVE RESSURE ENTILATION 24 Inch Frame Assembly Diagram...
  • Page 23: Parts List For Engine, Tach And Spark

    ENTRY OLUTIONS PARTS LIST FOR ENGINE, TACH AND SPARK Spark Arrester, Stickers and Honda GX Series Engines Reference Part Number Number Quantity S-1034 Spark arrester (Honda GX series engines) w/screw ........1 E-DA14 Address decal ....................1 E-DC13 Caution decal ....................1 E-DC13 Throttle decal ....................
  • Page 24: Tachometer/Hour Meter

    OSITIVE RESSURE ENTILATION Tachometer/Hour Meter Reference Part Number Number Quantity T-1031 Tiny-Tach ....................1 T-1032 Self-tapping screws, 8 x 3/8" ..............2 T-W075 Wire ties, 50# test ..................2 Motor Mount Bolt holding Grounding Clip ..........1...
  • Page 25: Parts List For Guard Mount

    ENTRY OLUTIONS PARTS LIST FOR GUARD MOUNT Reference Part Number Number Quantity G-1024 Guard mount bracket .................. 1 G-1035 1/8 U-bolt with nuts ..................1 F94225 ¼-inch x 1-inch Flat socket cap screw ............1 G-1030 Guard mounting hardware, ¼ NF ............... 2 G-1031 Guard mounting hardware, 5/16 NF ............
  • Page 26: Guard Mount Pictures

    OSITIVE RESSURE ENTILATION Guard Mount Pictures...
  • Page 27: Propeller Orientation

    ENTRY OLUTIONS PROPELLER ORIENTATION Toward Crush Plate Toward Engine PARTS LIST FOR PROPELLER MOUNT Reference Part Number Number Quantity P-1026 Stainless set screw ..................1 P-1029 Cap screw, (prop safety bolt), 5/16-inch x ¾-inch ........1 P-1028 Internal star washers, 5/16-inch ..............1 P-1027 Fender washer, 5/16-inch ................
  • Page 28: Propeller Hubs And Tab Washer Pictures

    OSITIVE RESSURE ENTILATION Propeller Hubs and Tab Washer Pictures...
  • Page 29: Parts List For Front Of Guard

    ENTRY OLUTIONS PARTS LIST FOR FRONT OF GUARD Reference Part Number Number Quantity Guard front, one of the following: QUABU120F 20-inch Fan guard front ................1 QUABU124F 24-inch Fan guard front ................1 G-W075 ® sticker .................. 1 ENTRY G-1040 ¼”...
  • Page 30: Parts List For Light Option

    OSITIVE RESSURE ENTILATION PARTS LIST FOR LIGHT OPTION Reference Part Number Number Quantity EPLHousing Light housing with switch ................1 L-1001 Butt connector ..................... 1 L-1002 Upper light mounting hardware ..............1 L-1003 Lower light mounting hardware ..............1 Frame (see frame parts list and picture) L-1004 Fuse holder ....................
  • Page 31: Torque Values

    ENTRY OLUTIONS TORQUE VALUES Fan Component Torque Values (ft. lbs.) 5/16-inch Cap screw (engine mounting bolts) 17 to 21 ¼-inch x ½-inch Cap screw (rear guard to guard mount 9 to 11 tubing) 5/16-inch Cap screw (rear guard to aluminum engine block) 8 to 10 Propeller hub set screw 9 to 11...

This manual is also suitable for:

20gx12024gx12024gc16024gx16020gc16024gx200 ... Show all

Table of Contents