1. Connect the Ground Terminal – Ensure the generator is properly grounded. 2. Check Indicator Lights – If the output indicator (green) does not light up and the overload indicator (red) is on, turn off the engine toggle switch and wait until the overload indicator goes out. 3. Restart the Generator – Follow the "Starting the Generator" procedure to restart it. 4. Check the Connected Device – Ensure that the connected device is turned off before plugging it into the generator's AC outlet to prevent sudden startup and possible injury. 5. Turn On the Generator – Once the output indicator (green) lights up, turn on the generator. 6. Monitor for Overload Issues – If the overload indicator remains on after several consecutive starts and no load is connected, service the generator at an authorized center.
This answer is automatically generated
Robin
June 18, 2025
can you please tell me the spark plug part number for the GT 6000
Petrol Powered Inverter Generator Table of Contents Safety ..................................1 Parts Diagrams ................................. 2 Generator ..............................2 Control Panel ..............................3 Set-Up ..................................3 Pre-Operation Checklist ..........................3 Check the engine oil level ........................3 Check the Fuel Level ..........................4 Check the Air Filter ..........................
Petrol Powered Inverter Generator Safety • Before operating the generator, carefully read and understand this manual, to greatly reduce the chances of personal injury or equipment damage. • Exhaust contains poisonous carbon monoxide. Do not operate the generator in poorly-ventilated place. Ensure that the generator is located in a dry, airy, clean place.
Petrol Powered Inverter Generator Control Panel Set-Up Pre-Operation Checklist IMPORTANT! Ensure that the generator is placed horizontally and that it is turned off. Check the engine oil level IMPORTANT! Using 2-stroke engine oil could shorten the engine life. Use a high-quality 4-stroke engine oil, which must meet or exceed US automobile manufacturer's requirements for the classification of the American Petroleum Institute, SF level.
Petrol Powered Inverter Generator Check the Fuel Level 1. Use automotive gasoline (preferably unleaded or low-lead gasoline to reduce combustion and reduce environmental pollution). 2. When the oil level is too low, add fuel to a predetermined level. 3. Never use gasoline or a mixture of oil and gasoline. 4.
Petrol Powered Inverter Generator WARNING! • Gasoline is explosive and flammable under certain conditions. • When refuelling, turn off the generator and do it in a well-ventilated area. Do not store the generator near fire or areas with strong sources of heat. •...
Petrol Powered Inverter Generator Operation Starting the Generator IMPORTANT! Before starting the engine, disconnect the load between the DC sockets first. 1. Turn on the Oil Switch 2. Set the generator’s engine switch to the "ON" position.
Petrol Powered Inverter Generator 3. Pull the starter cord until you feel resistance, then following the direction of the arrow indicated in the figure below, quickly pull the handle to start the generator. CAUTION! • Do not let go of the starter cord after pulling it, but rather put it back slowly. •...
Petrol Powered Inverter Generator • Do not use the generator for purposes other than what it were intended to do. Please observe the following additional requirements: − Do not do a parallel connection with the generator. − Do not lengthen the exhaust pipe. −...
Page 11
Petrol Powered Inverter Generator NOTE: • Before connecting a device to the generator, check whether the device is in good working condition. If the device’s required power exceeds that of the generator, connect the needed cable equipment, then start the generator.
Petrol Powered Inverter Generator 2. Requirements for starting the generator: When the output indicator light (green) does not light-up, and the overload indicator (red) is lit-up instead, turn off the toggle switch of the engine, then wait after the overload indicator light goes out. After that, follow Starting the Generator procedure to start the generator again.
Page 14
Petrol Powered Inverter Generator NOTE: − To disconnect the charging wire when it is connected between the battery and the generator, disconnect it next to the battery to prevent sparks from forming. − When the charging wire is connected to a battery that is mounted on a car, first disconnect the battery ground cable, charging cable, etc.
Petrol Powered Inverter Generator Oil Alert System The Oil Alert system is designed to prevent engine damage due to lack of lubricant and/or oil. Before the oil falls below the safety line in the crankcase, the oil alert system will automatically shut down the engine (the engine switch will remain in the "ON"...
Petrol Powered Inverter Generator 3. Set the oil switch to the “OFF” position. Maintenance Maintenance and adjustment schedule was developed to ensure that the generator is kept in the best working condition. CAUTION! Turn off the generator first before doing any maintenance on it. If the generator needs to be maintained while it is still running, it must be done in a well-ventilated area.
Petrol Powered Inverter Generator NOTES: Normal maintenance intervals. Maintain frequently if located in a heavily polluted area. Periodic maintenance schedule is calculated according to the ambient temperature of 25°C. If the ambient temperature exceeds 30°C, please lessen the load power or shorten the oil change interval. Changing the Oil When the engine is hot, the quickly and thoroughly discharge the oil.
Petrol Powered Inverter Generator NOTE: Please wash your hands with soap and water after changing the oil. In order to meet environmental requirements, we recommend that the old oil be sealed in a container and hand it over to your local service station and recycling centre. Do not pour oil onto the ground or in the trash. Air Filter Maintenance A dirty air filter can block the airflow flowing into the carburettor, which could result in the carburettor malfunctioning.
Petrol Powered Inverter Generator 4. Visually inspect the spark plug if the insulator is broken, which must be discarded. If you want to re-use the spark plug again, use a brush to clean the spark plug. 5. Measure the spark plug gap with a thickness gauge; the spark plug gap should be between 0.6 –...
Petrol Powered Inverter Generator Transportation and Storage NOTE: To prevent fuel leakage during transportation or temporary storage, turn off the oil switch. When transporting the generator: • Do not fill up the fuel tank too much (filler should have no fuel in it). •...
Page 21
Petrol Powered Inverter Generator 2. Drain the oil. 3. Remove the spark plug, then pour a tablespoon of clean engine oil into the cylinder, pulling the handle several times to start the bulk of oil spill, and then install the spark plug. 4.
Petrol Powered Inverter Generator Troubleshooting Generator Isn’t Starting NOTE: If the generator cannot be started when pulling the starting handle oil after the warning light flashes, lightly shake the generator side-to-side a few times to ensure that the oil alarm system is working properly. If you still cannot start the generator, please start troubleshooting.
Petrol Powered Inverter Generator Power Shortage Technical Specifications Max Output 3700W / 3.7kW / 3.7kVA Continuous 3200W / 3.2kW / 3.2kVA Rated Output AC Voltage 240V 50Hz Output Type 240V 15Amp socket DC Output 12V - 8.3A USB Socket Dual PLEASE NOTE: 'Continuous Rated Output' is what power this generator consistently and reliably provide.
Page 25
Some experts believe the incorrect or prolonged use of almost any product could cause serious injury or death. For information that may reduce your risk of serious injury or death consult thepoints below and additionall y , the information available at www.datastreamserver.com/safety - Consult all documentation, packaging and - The product has been supplied by a general merchandise...
Need help?
Do you have a question about the GT6000 and is the answer not in the manual?
Questions and answers
How to start up checklists
1. Connect the Ground Terminal – Ensure the generator is properly grounded.
2. Check Indicator Lights – If the output indicator (green) does not light up and the overload indicator (red) is on, turn off the engine toggle switch and wait until the overload indicator goes out.
3. Restart the Generator – Follow the "Starting the Generator" procedure to restart it.
4. Check the Connected Device – Ensure that the connected device is turned off before plugging it into the generator's AC outlet to prevent sudden startup and possible injury.
5. Turn On the Generator – Once the output indicator (green) lights up, turn on the generator.
6. Monitor for Overload Issues – If the overload indicator remains on after several consecutive starts and no load is connected, service the generator at an authorized center.