  • Page 2 AT-2030 Portable Vibration Calibrator. The AT-2030 is designed as a rugged, battery powered, vibration sensor test set. The AT-2030 is meant for use in the field or laboratory for the verification of control room working conditions or to verify the performance of vibration transducers.
  • Page 3 1) To shake or excite a transducer under test. In shake mode, AT-2030 can be used as a variable frequency, variable amplitude shaker. In this mode, the frequency and amplitude are set manually by the user, while the computer provides high accuracy measurement signals.
  • Page 4 Note about battery operation: AT-2030 is powered by one 5 amp hour, sealed lead acid, rechargeable battery as its primary power source. This battery is designed to be continuously charged at a trickle rate once the battery reaches 100%.
  • Page 5 If deep discharge occurs, the battery charger is set to recharge over two or more days. This is normal operation to prevent battery damage. Accessories: AT-2030 comes standard with the following pictured accessories: 1) Universal Velocity Mounting Adapter with ¼-28 mounting hex screw………………………….(MNT-112) 2) Universal Accelerometer Mounting Adapter with ¼-28 mounting hex screw………….…..(MNT-113) 3) 2-56 Adapter………………………………………………………………………………………………………………...
  • Page 6 AGATE TECHNOLOGY AT-2030 OPERATORS MANUAL 5/32 Hex L-Wrench. (ACC-101) 10-32 to BNC adapter cable for sensitivity measurement. (CAB-100) AC Power Cord 120v (PWR-100) AC Power Cord 220-240v (PWR-101) Optional Accessories Include: Chadwick-Helmuth Velocimeter ……………………………………………………………..(CAB 101) IEPE Accelerometer 2 pin Mil………………………………………………………………… (CAB-102) IEPE Accelerometer 3 pin Mil ………………………………………………………………….(CAB- 103)
  • Page 7: Software Update Installation

    Software Update Installation: AT-2030 features software update support to load in sensor information, custom databases, bug fixes, software add-ons and more. 1) To update your unit to the most current software visit www.agatetechnology.com/upgrade...
  • Page 8: Main Menu

    From this screen you will be able to adjust frequency and amplitude. Press down on the frequency knob or select from the touch screen to begin. As the AT-2030 is adjusted the three vertical bars will indicate its status. OUT: The percentage of maximum output supplied by the main amplifier.
  • Page 9: Additional Information

    AGATE TECHNOLOGY AT-2030 OPERATORS MANUAL Additional Information Maximum weight recommendation chart: Frequency 0-100 Grams 100-250 Grams 250-500 Grams 500-750 Grams 10-100 Hz 10g’s 4g’s 2g’s 100-1000 Hz 7g’s 4g’s 2g’s 1000-10000 Hz 3g’s 1.5g’s 760-215-9670...