before installing and using this unit SAFETY PRECAUTIONS CAUTION RISK OF ELECTRIC SHOCK . DO NOT OPEN ! CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK NO USER SERVICEABLE DO DOT OPEN COVERS . PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lighting flash with a arrowhead symbol , in an equilateral triangle , is intended to alert the user .
The exclamation point within an equilateral triangle is intended to alert the user to reference of the important operating and maintenance ( servicing ) instructions . THE PRODUCT CODE MARKED ON THE BOTTOM COVER PLEASE FILL THE CODE IN THE FOLLOWING BLANK PLEASE SAVING THIS SPECIFICATION CAREFULLY , SO THAT CHECKING...
Page 4
----------------------------------------------17 Dimension of the Product-----------------------------------------------17 The Style of Installation--------------------------------------------------17 The step of high speed dome installs -------------------------------18 The step of Middle/low speed dome installs----------------------21 Technical data table ------------------------------------------------------------25 7.Troubleshooting - -----------------------------------------------------------------28 Appendix Lighting Proof and Surge Signal Proof---------------------------------29 Ⅰ The Cleaning of Clear Down Cover-------------------------------------30 Ⅱ...
1. Important Safeguards 1. All the safety and operating instructions should be read before the units is operated. 2. This unit should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply you plan to use, consult your appliance dealer or local power company.
Page 6
6. The product should be indoor installed operated avoid rain moisture. Do not use it in wet places. If outdoor installation is needed, the closed protect cover should be used and it is absolutely prohibited to use it in open air independently. 7.
2. Description of Functions The intelligent dome camera is a hi-tech CCTV product which incorporates high-clarity color camera, panoramic speed-variable PAN/TILT, multifunctional decoder, universal character generator, CPU processor, memory chip into a whole. It can largely reduce connection and installation processes of components in the system, rise up reliability of the system and facilitate installation and maintenance.
speed the location precision up to ±0.2° High Intelligent Degree Dome general functions a.As much as 128 preset positions can be preset with powerless memory b. The camera can scan horizontally between two points and scan speed can be modified. The positions of linear scan are optional and the dome camera can scan the range larger or smaller than 180°...
4. Functions of the Camera (icons can be displayed on the screen when the option DISPLAY of the camera is ON,Only for 18× Camera) a. Description of the Focus Control Mode: the user can adjust the focus of the camera manually. When the camera is on near focus, the icon appears on the screen;...
brightness is extremely low. Normally the camera works on the automatic state. In case the external brightness is lower than 1Lux, the camera can be switch to the Zero illumination state automatically and icon appears on the screen. You can also set the Zero illumination state manually.
function of camera. 2.1.5 PROGRAM: to enter the setup of enhanced function of dome camera. 2.1.6 PAL CAMERA: PAL/NTSC switching to suit the camera. 2.1.7 CAM DEFAULT SET: to reset default setup of camera. 2.1.8 DOME RESET: to reset the dome camera. 2.1.9 EXIT: to quit the main menu.
2.3.2 BACK LIGHT: backlight compensation ON/OFF. 2.3.3 ICR SHOT: low shooting , ON/AUTO 2.3.4 IRIS: setup of automatic iris AUTO/MANU. 2.3.5 D-ZOOM: setup of digital zooming ON/OFF. 2.3.6 FOCUS: setup of automatic focusing AUTO/ MANU. 2.3.7 WB SET: setup of white balance. ATW / INDOOR / OUTDOOR / ONEPUSH / AUTO / MANU 2.3.8 MENU OF CAM: blank...
Page 13
2.4.4.3 DWELL TIME:to set the time of automatic HOME, which means the camera shall return HOME if it is not controlled in a period of time which can be from 1 to 99 minutes. 2.4.4.4 RETURN: return to the menu one level higher. 2.4.5 RETURN: return to MAIN MENU.
RIGHT, and operate and exit by OPEN button. The start position and the end position of auto scan are set by options 1 and 2 in this submenu. 2.6.4 SET TITLE: to edit titles of preset position. Only previous 63 preset points have their titles.
Page 15
POS – No. of preset position SP – leaving speed TM – dwelling time After entering into edit area, screen shows as follows: Edit Area, data of 2 patrol position appears on one line SEQ:01– It means the set No.1 patrol CLOSE: EXIT–...
modify data by TILT UP/DOWN. Press buttons for one second to speed up operation. Press CLOSE button to exit edit state and store modifications. The title of preset point has 8 characters in maximum such as 0-9, A-Z, +, - and space. Note: the first character should be 0-9 or A-Z, otherwise it means to delete the title of the preset point, and when preset point is adjusted, only “NO.XXX”...
Page 17
RS485 RS485 RS485 RS485 Video Power Adapter Power Adapter Power Adapter Power Adapter Power Adapter Power Adapter Power Adapter Power Adapter Video Video Video Video Monitor 2 Monitor 2 Monitor 1 Monitor 1 Video In Video In Video In Video In Video Out Video frequency RS485...
Page 18
SW 1 120Ω terminal resistor is Protocol Select Speed Dome Address Select connected on RS485 Bus 120Ω terminal resistor is connected on RS485 Bus Vertical view Connector Pin Figure 2 Middle speed and low speed dome 9 10 120Ω terminal resistor is Protocol Select Address Select connected on RS 485 Bus...
DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6 SAMSUNG NEON Santachi PELCO-D PELCO-P/4800 PELCO-P/9600 PANASONIC Longcomity HUNDA600 LILIN VICON MOLYNX KALATEL Reserved ALEC Ultrak Table 2 Some protocols and the states of the coding switches of normal baud rate of these protocols are shown as follows: PANASONIC/9600 Bp s NEON/9600Bps KALATEL /4800 Bps...
the baud rate of communication and 4 different baud rates can be selected in maximum. If the controller adopts non-standard baud rate, you can adjust it to be identical with that of the main machine as per the following table. Baud Rate of Setup of Baud Rate Communication...
Figure 4 2. The Style of Installation Wall Installation Figure5 b)In-Ceiling Installation Figure6 Product disposition overall size -18181818...
Page 23
Figure 7 Indoor wall outdoor wall indoor/outdoor 3. The Installation installation In-Ceiling installation step high speed dome installs (taking wall-installing style as example) 1) Unpacking the carton and carefully take out the dome camera and its attachments. Take out system control wires from the bracket (see Figure 8).
Page 24
Install the ball on the bracket (Figure 12) Trip wire to give alarm marking (Figure 13 ), System pilot wire marking(Figure 14) RED1:ALARM - 1 IN ORANGE 2:ALARM - 2 IN YELLOW 3:ALARM - 3 IN GREEN 4:ALARM - 4 IN BLACK 5:...
Page 25
sec. Once the dome have alarm input, dome will not respond“scanning” 、“ patrol” 、“ remember tracking”etc function. VIDEO OUT Channel 4 ALM-4: VIDEO GND collector alarm input:1 ALM-3: Channel 3 collector alarm input:2 1:AC24V IN Channel 2 ALM-2: collector alarm input:3 2:AC24V IN Channel 1 ALM-1:...
Page 26
10) Rotate the vitreous cover on dome counterclockwise and take it out. Note: if Fixed the Speed Dome Camera in the aluminum alloy ball, you must take out the vitreous cover on dome. Otherwise, it will effect picture quality. (see Figure 17) 11) Aiming the “MARK”...
Page 27
3) 4 bolts black coats which the inside lining squeeze out, take down the inside lining black cover(Figure 21) 4) Based on the coding switches shown as Figure 2, set up the protocol used by the camera and the baud rate as per the state according to Table 2.
Page 28
Take out system control wires from the bracket(Figure 25) Figure 24 Figure 25 Fixes the support on the wall (Figure 26) 10) Fixes the dome to the support above Figure 26 11) System pilot wire after (Figure 27 ) marking meets, after the electricity then controlled the ball machine for the system on.
Page 29
camera and its attachments. 2) takes out the support, fixes the support in the wall goes against (Figure 28) 3) Take out system control wires from the bracket(Figure 29) 4) Fixes the ball cover to the support above(Figure 30) 5) System pilot wire after (Figure 15) marking meets, after the electricity then controlled the ball machine for the system on.
Page 30
6. Technical data table 1. High speed Dome cameras technology Power supply AC24V 50/60Hz Power consumption Indoor dome:15W Outdoor dome:35W Sync system Internal/External selectable Preset 128 presets Auto tour Pattern Alarm 4 channels input & 1 channel output Privacy masking 6 (some model only) Zoom-rotation Control speed auto adjust according to the focus...
Tilt range 0-- 90° Tilt speed Maximum 12°/s Communication RS485 Baud rate 2400/4800/9600/19200 bps Relative humidity 10-75%(without agglomeration) Work temperature Indoor:0 — +40 ℃ ℃ Outdoor :– 35 -- +55 ℃ ℃ Table 5 3. Camera Optional data table Mode 16×...
Page 32
>46dB ≥50dB Video output 1.0±0.2Vp-p Table 6 4. Middle/low speed dome Special function control.Some special protocol such as “Santachi”,”PELCO-D” and “PELCO-P” without the command of control some especial functions, in order to use the special functions of dome, so we changed the command of calling/setting NO.51 preset to NO.64 preset to control them.
function switch able Table 7 7. Troubleshooting Problems Possible Causes Remedies No action when Power supply fault Replace power is Bad connection of the power Correct switched on Transformer damaged Replace Abnormal self- Mechanical failure Repair check. Images Camera inclined Reinstall with motor Power supply not enough...
Page 34
Keep the communication cables at least 50 meters away from high voltage equipment or cables. Make outdoor cable laying-out under eaves as possible as you can. In open area shield cables in steel tube and conduct a single point ...
Figure 31 Appendix Ⅱ: The Cleaning of Clear Down Cover To obtain constant clear videos, user should clean the down cover periodically. Be cautious when cleaning. Hold the down cover ring only to avoid direct touch to the acrylic down cover. The acid sweat mark of fingerprint will corrode the coating of down cover and scratch on down cover will cause vague images.
Page 36
The maximum load capacity is 32 unit loads (including main controller and controlled equipment). 2. Transmission distances of RS485 Bus When user selects the 0.56mm (24AWG) twisted pair wires as data transmission cable, the maximum theoretical transmitting distances are as follows: Baud Rate Maximum Transmitting Distance...
Page 37
..120Ω 120Ω Main controller Figure 33 The connection of 120 Ω termination resistor: The termination resistor is ready on the Protocol PCB. There are two kinds of connection. Refer to the Protocol PCB jumper setting form (refer to Picture 2,3).
Page 38
Figure 34 In such circumstances the factory recommends the usage of DR- HB16 RS485 distributor. The distributor can change the star configuration connection to the mode of connection stipulated in the RS485 standards. The new connection achieves reliable data transmission (refer to Picture 35). Figure 35 -34343434...
Need help?
Do you have a question about the VC-EX861 and is the answer not in the manual?
Questions and answers