P R E C I S I O N I N S T R U M E N T A T I O N Distributed by: Manufactured by: IC 2-60-006-00-00555/REV :A/15/05/2013 Sifam Tinsley Instrumentation Inc Veracious Canada Inc 3105 Creekside Village Dr, 1101 Britannia Rd E,...
Page 2
WARRANTY Dear Customer, You are now the privileged owner of Gamma 10 Digital Multimeter / Accessories, a product that ranks the first of its kind in the world. Company provides 36 months warranty from the original date of purchase against defective material and workmanship.
(1) Liquid crystal display (10) Symbols for displaying (2) ON / OFF pushbutton selected functions (3) Pushbutton for data hold and (11) Display for selected function MIN/MAX storage functions (12) Display for the unit of (4) Pushbutton for manual range measured quantity selection (13) Over range indication...
These instruction must be followed in all respects. For your safety and for protection of the meter, the Gamma 10 meter is Caution : fitted with an automatic terminal blocking system. It is coupled with the...
Meaning of the symbols on the device Ambient conditions Functional temperature range -20 C... + 50 C Warning of a danger point (Attention, refer to documentation) Storage temperature range -25 C... + 70 C Climatic class 2z/-20/50/70/75 % with reference to Ground connector VDI / VDE 3540 Altitude...
Liquid crystal display Digital display The digital display (9) shows the measured value with correct location of decimal point and sign. The selected measuring unit (12) and the function (11) are simultaneously displayed. When measuring DC quantities, a minus sign appears in front of the digits, when the positive pole of the measured quantity is applied to the “...
1) Reactivated by falling below the specified limits of the measured value . 2) Referring to AC values. 3) When storing a value for the first time twice a sound signal. For following “holds” only twice if actual hold value differs from first stored value by less than 100 digits.
Reference conditions Ambient temperature : +23 C +2K Relative humidity : 45% ... 55 % RH Zero adjustment on the 300 mV --- measuring range You can adjust the zero on the 300 mV --- measuring range : Frequency of the measured quantity : 45 Hz...
Page 10
Voltage Measurement - - - - - - - - - - - - - - - 1 min + ( - ) / ~ continuou- - ( + ) / ~ Voltage Measurement on electrical system up to 1 min 1000 V with the KS30 measuring adapter : U= 1V ...10V...
Note The multimeter does not contain termination resistors. The input impedance is 5 MΩ respectively. In order to measure correctly on unterminated objects, you have to connect the termination resistor to the terminals. Please take the power dissipated by the termination resistor into consideration. Reference measurements ê...
Voltage of the system does not exceed 1000 V. — Make the measuring circuit connections mechanically strong and secure so that they do not accidently open. The conductor cross sections and connection points should be designed to avoid excessive heating. —...
Page 14
Hardware : You need w An IBM AT - compatible PC with 640kB main memory for the DOS version A WINDOWS-executing, IBM compatible PC with 2 MB main memory for the WINDOWS version. w A VGA or EGA monitor; a Hercules monitor can also be used for the DOS 2.1058 version w A hard disk with 3 MB free storage space...
16. RS-232C interface Reverse direction or interruption : The Gamma 10 multimeter is fitted with a serial RS-232C interface for The meter indicates overrange “ OL ” transmission of measured data to electronic data precessing systems. The...
w by pressing the yellow multi- function pushbutton (5) longer, this Set the function selector switch (6) to V ê is Confirmed Connections are made the same way as for voltage measurement. See foot ê w by the buzzer sounding twice, by switching the meter off. note 6) on page 22.