1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS P200W2 Series Dehydrator! We here at PUREGAS are very proud of our products and we are committed to providing you with the best value and service possible. We are sure that you will be satisfied with your new Dehydrator and would like to thank you for choosing PUREGAS for your Dehydrator requirements.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 4. Safety & Warning Information This section contains general information about safety and warning points to consider and adhere to during installation, and operation of your Dehydrator. PLEASE READ THIS SECTION BEFORE PERFORMING ANY OPERATION OR PROCEDURE ON YOUR DEHYDRATOR.
Page 7
Incoming power to Dehydrator must be: 10 amp service recommended 24 VDC for P200W2 model (7 Amp slow blow fuse) 48 VDC for P208W2 model (7 amp slow blow fuse) 85 - 264 VAC, 1 Phase for P200WA2 model...
5. Overview & Specifications 5.1 Product Description The P200W2 Series Dehydrator from PUREGAS is designed to intake wet ambient air and remove the moisture for delivery to applications requiring an on-demand source of dry, pressurized air. This process is fully automatic and will remain consistent with no required periodic maintenance.
Incoming power to Dehydrator must be: 10 amp service recommended 24 VDC for P200W2 model (7 Amp slow blow fuse) 48 VDC for P208W2 model (7 amp slow blow fuse) 85 - 264 VAC, 1 Phase for P200WA2 model...
6.2.3.3 Meets the following power requirements: 10 amp service recommended 24 VDC for P200W2 model (7 Amp slow blow fuse) 48 VDC for P208W2 model (7 amp slow blow fuse) 85 - 264 VAC, 1 Phase for P200WA2 model (5 amp slow blow fuse) 6.2.4 Notify the alarm center of the installation and potential for alarms during...
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 6.5 Installation Steps 6.5.1 Use a Box Cutting Knife to open and remove the Dehydrator and all contents from packaging. NOTE: If ANY SHIPPING DAMAGE is detected, file a claim with the shipping company prior to continuing the installation procedures.
Page 14
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide For Rack Mounted Installation: a. Attach Mounting Brackets to the Dehydrator with mounting flanges facing forward as shown. Use Hardware A and Phillips Head Screwdriver. NOTE: Mounting Brackets can be attached in a number of positions; front-to-back. Choose the mounting position that meets your rack mounting requirement.
Page 15
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide For Vertical / Wall Mounted Installation: IMPORTANT! PUREGAS recommends keeping the area beneath a vertical mounted dehydrator clear. a. Attach Mounting Brackets to the Dehydrator with mounting flanges facing UP as shown. Use Hardware A and Phillips Head Screwdriver.
Page 16
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 6.5.5 Connect Power to the Dehydrator: For 24 VDC and 48 VDC Dehydrators: a. Using Terminal Crimpers, wire the DC Power Harness to power supply: WHITE: Positive Voltage BLACK: Negative Voltage GREEN: Ground (Frame or Power Supply Ground) b.
Page 17
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide b. Connect the AC Power Cord (110 VAC or 220 VAC) to the Power Port on the back of the Dehydrator. 6.5.6 Power the Dehydrator ON. NOTE: POWER Button and Display Screen WILL be illuminated when power is ON.
Page 18
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 6.5.9 Press the Up () Arrow Button to access the Set Up Menu. 6.5.10 Enter the Keyword (default Keyword is 123456) – 6.5.10.1 Press the Left () & Right () Arrow Buttons to move the underscore beneath the digit to change.
Page 19
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide The System Operations Section is used to set the range for the system pressure. When the system pressure reaches the High Pressure setting, the compressor will turn OFF. When the system pressure reaches the Low Pressure setting, the compressor will turn ON.
Page 20
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 6.5.14 Press the Up () Arrow Button to access the Set Low Pressure screen. 6.5.15 Set Low Pressure (default setting is 2 KPa) – 6.5.15.1 Press the Function () Button to Set. 6.5.15.2 Press the Left () &...
Page 21
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 6.5.17 Set Network Configuration (if applicable) - 6.5.17.1 Press the Up () & Down () Arrow Buttons to move the underscore beneath the “N” in Network Setup. 6.5.17.2 Press the Function () Button to Enter Network Setup.
Page 22
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 6.5.17.4 Press the Up () Arrow Button to scroll to the Set Subnet Mask screen. 6.5.17.5 Set Subnet Mask (default is 255.255.255.000) - 6.5.17.5.1 Press the Function () Button to Set the Subnet Mask.
Page 23
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 6.5.17.7 Set Gateway Address (default is 000.000.000.000) - 6.5.17.7.1 Press the Function () Button to Set the Gateway Address. 6.5.17.7.2 Press the Left () & Right () Arrow Buttons to move the underscore beneath the digit to change.
Page 24
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 6.5.17.9 Change Keyword (default is 123456) 6.5.17.9.1 Press the Function () Button to change the Keyword. 6.5.17.9.2 Press the Left () & Right () Arrow Buttons to move the underscore beneath the digit to change.
Page 25
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 6.5.19 Connect a Network IP cable to the UTP Port on the back of the Dehydrator (if applicable). 6.5.20 Let Dehydrator run until the Humidity is 5% or below. (May take 15 – 20 minutes).
Page 26
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 6.5.22 Connect the air supply line to the Dehydrator. (Use 1/4” Reducer as required.) NOTE: Compressor should run until the High Pressure setting (Section 6.5.13 ) is reached. 6.5.23 Press the RESET Button to clear any alarms triggered during installation.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 6.5.24.2 Connect the Alarm Harness to the Alarm Port on the back of the Dehydrator. 6.5.25 REGISTER YOUR DEHYDRATOR. See Section 7. for details. 6.6 Installation Checklist No shipping damage was detected.
P200W2 Series Dehydrator User’s Guide 7. Registering Your Dehydrator Please take a moment to register your PUREGAS P200W2 Series Dehydrator. Registering is necessary to activate the Limited Warranty on your product. Once you register, you are eligible to receive free technical support, as well as updates concerning your PUREGAS products.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8. Operating Your Dehydrator 8.1 Safety & Warning Information WARNING! For your safety, all the information in this User’s Guide must be followed to minimize the risk of electrical shock, and prevent property damage or personal injury.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.2 Connecting an Air Supply Line WARNING! DO NOT CONNECT THE DEHYDRATOR TO THE SUPPLY LINE UNTIL THE HUMIDITY READING IS 5% OR LESS. 8.2.1 Connect the Precision Bleed Orifice Fitting to the Dehydrator Outlet Port Fitting.
Incoming power to Dehydrator must be: 10 amp service recommended 24 VDC for P200W2 model (7 Amp slow blow fuse) 48 VDC for P208W2 model (7 amp slow blow fuse) 85 - 264 VAC, 1 Phase for P200WA2 model (5 amp slow blow fuse) 8.3.1 Press the POWER Button.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.4 Using the Front Panel Display CAUTION! The Display Screen is covered by a clear protective layer that guards against Electrostatic Discharge (ESD). DO NOT REMOVE THIS LAYER. 8.4.1 ALARM LED – Indicates an alarm is present.
Page 33
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.4.5 Display Screen - Shows the current Dehydrator readings and status. Will cycle between the following information screens (unless the HOLD Button has been pressed): 8.4.5.1 SYS STATUS Screen SYS STATUS - Running Status of the system: ...
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.4.5.2 PRESSURE Screen PRESSURE – Current pressure of the system (will fluctuate between the Set Low Pressure and Set High Pressure values). HUMIDITY – Humidity level of the Dehydrator. CAB TEMP – Temperature of the Dehydrator cabinet compartment.
Page 35
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.5.3 High Humidity Alarm – Occurs when the HUMIDITY level rises above the alarm set point. (Default setting is 7.0%) If the humidity level exceeds the alarm set point for a period of time, the Dehydrator will go into SHUTDOWN to prevent the output of wet air.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.6 Accessing the Set Up Menu The Dehydrator has three (3) Set Up Sections: System Operations – Used to set the range for the system pressure. When the system pressure reaches the High Pressure setting, the compressor will turn OFF.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.7 Using the System Operations Menu In the Set Up Menu: 8.7.1 Press the Up () & Down () Arrow Buttons to move the underscore beneath the “S” in System Operations. 8.7.2 Press the Function () Button to Enter System Operations.
Page 38
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.7.4 Press the Up () Arrow Button to access the next screen. 8.7.5 Set Low Pressure (default setting is 2 KPa) – 8.7.5.1 Press the Function () Button to Set. 8.7.5.2 Press the Right () &...
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.8 Using the Alarm Set Points Menu In the Set Up Menu: 8.8.1 Press the Up () & Down () Arrow Buttons to move the underscore beneath the “A” in Alarm Set Points.
Page 40
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.8.3 Press the Up () Arrow Button to access the next screen. 8.8.4 Set Low Pressure Alarm Point (default setting is 1.0 KPa) – 8.8.4.1 Press the Function () Button to Set. 8.8.4.2 Press the Left () &...
Page 41
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.8.6 Set High Cabinet Temperature Alarm Point (default setting is 49 C) 8.8.6.1 Press the Function () Button to Set. 8.8.6.2 Press the Left () & Right () Arrow Buttons to move the underscore beneath the digit to change.
Page 42
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.8.8 Set Low Cabinet Temperature Alarm Point (default setting is 1 C) 8.8.8.1 Press the Function () Button to Set. 8.8.8.2 Press the Left () & Right () Arrow Buttons to move the underscore beneath the digit to change.
Page 43
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.8.10 Set High Humidity Alarm Point (default setting is 7%) – 8.8.10.1 Press the Function () Button to Set. 8.8.10.2 Press the Left () & Right () Arrow Buttons to move the underscore beneath the digit to change.
Page 44
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.8.12 Set High Duty Cycle Alarm Point (default setting is 50%) - 8.8.12.1 Press the Function () Button to Set. 8.8.12.2 Press the Left () & Right () Arrow Buttons to move the underscore beneath the digit to change.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.9 Using the Network Setup Menu In the Set Up Menu: 8.9.1 Press the Up () & Down () Arrow Buttons to move the underscore under the “N” in Network Setup. 8.9.1.1 Press the Function () Button to Enter Network Setup.
Page 46
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.9.3 Press the Up () Arrow Button to access the next screen. 8.9.4 Set Subnet Mask (default is 255.255.255.000) - 8.9.4.1 Press the Function () Button to Set the Subnet Mask. 8.9.4.2 Press the Left () &...
Page 47
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.9.6 Set Gateway Address (default is 000.000.000.000) - 8.9.6.1 Press the Function () Button to Set the Gateway Address. 8.9.6.2 Press the Left () & Right () Arrow Buttons to move the underscore beneath the digit to change.
Page 48
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.9.8 Change Keyword (default is 123456) 8.9.8.1 Press the Function () Button to change the Keyword. 8.9.8.2 Press the Left () & Right () Arrow Buttons to move the underscore beneath the digit to change.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.10 Connecting Alarms 8.10.1 Wire the Alarm Harness to monitoring device using the table below for reference. Wire # Wire Color Function Power Fail SHORT on Alarm Alarm BLACK BLACK SHORT Common on Alarm...
192.168.1.101. This will make the Laptop/PC compatible with the Dehydrator. Use Internet Explorer (6.0 or newer) or Mozilla Firefox Web Browser. 8.12.1 Type the IP Address of the P200W2 Series Dehydrator in the Address text box of the web browser. Page 50 of 82...
Page 51
P200W2 Series Dehydrator. This screen is informational only. Alarm Screen - Displays all the Alarms registered by the P200W2 Series Dehydrator. This screen is informational only. Firmware Screen – Allows the user to upload any software updates or upgrades to the P200W2 Series Dehydrator.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.13 Using the Status Screen Displays the readings and alarms monitored in the P200W2 Series Dehydrator. Provides remote ALARM RESET. Readings are displayed in BLACK unless an alarm is present. Alarms are displayed in next to the parameter in alarm.
Page 53
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.13.1 Resetting an Alarm 8.13.1.1 Click on the ALARM RESET Button to remotely reset Dehydrator alarms displayed on Status Screen. 8.13.1.2 Enter Keyword (default is 123456) 8.13.1.3 Click on SUBMIT Button when done.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.14 Using the Setup Screen All configurations of Set Points, Setups, and Keyword can be made in this screen. NOTE: Reference Appendix Section 12.1 for Limits, Defaults, and Formats. Values in BLUE represent the current setting.
Page 55
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.14.1 Changing a Set Point or Setup value: 8.14.1.1 Click on the value to change (in BLUE). 8.14.1.2 Type in the new value. 8.14.1.3 Click the ENTER Button when done. 8.14.1.4 Enter Keyword (default is 123456) 8.14.1.5 Click on SUBMIT Button when done.
Page 56
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.14.2 Changing the Keyword 8.14.2.1 Click on CHANGE KEYWORD Button to change the keyword. 8.14.2.2 Type the Old Keyword. 8.14.2.3 Type the New Keyword. 8.14.2.4 Type the Confirm New Keyword. 8.14.2.5 Click on SUBMIT Button to confirm. This will lock in the new setting value.
8.15 Using the Event Screen Displays all events such as alarms, changes made, and alarm resets registered by the P200W2 Series Dehydrator. This screen is informational only. Click on the column headings to sort data according to that column.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.16 Using the Alarm Screen Displays all the Alarms registered by the P200W2 Series Dehydrator. This screen is informational only. Click on the column headings to sort data according to that column.
8.17 Using the Firmware Screen Displays the current firmware version and date of the P200W2 Series Dehydrators. Current Version: Displays the current firmware version of the P200W2 Series Dehydrator. New Version File: Displays the new location and new firmware version chosen.
Page 60
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 8.17.1 Updating the Firmware: 8.17.1.1 Click on BROWSE Button to locate the firmware file. 8.17.1.2 Navigate and Select the correct .bin file. Press the OK Button. 8.17.1.3 Click the ACCEPT Button when done 8.17.1.4 Enter Keyword (default is 123456)
P200W2 Series Dehydrator User’s Guide 8.18 Connecting via SNMP Using SNMP to connect and communicate with the P200W2 Series Dehydrator is dependent upon the specific SNMP Management software used on your network. This software requires a SNMP Definition & Configuration File (MIB file) in order to properly communicate with the Dehydrator.
Incoming power to Dehydrator must be: 10 amp service recommended 24 VDC for P200W2 model (7 Amp slow blow fuse) 48 VDC for P208W2 model (7 amp slow blow fuse) 85 - 264 VAC, 1 Phase for P200WA2 model...
WHITE wire BLACK probe to BLACK wire The voltage should measure 24 VDC for the P200W2 model and 48 VDC for the P208W2 model. 9.2.2.3 Re-connect the DC Power Harness to the Power Port on the back of the Dehydrator.
Page 64
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 9.2.3 For P200WA2 model: WARNING! Extreme care should be exercised to avoid contact with live electrical circuits. If unsure about performing the following procedure, contact an electrician. 9.2.3.1 Disconnect the AC Power Cord from the Power Port on the back of the Dehydrator.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 9.3 Testing High Pressure Alarm NOTE: All testing values are based on default Dehydrator settings, if settings have been changed, adjust testing values accordingly. 9.3.1 Make note of the current High Pressure setting.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 9.4 Testing Low Pressure Alarm NOTE: All testing values are based on default Dehydrator settings, if settings have been changed, adjust testing values accordingly. 9.4.1 Make note of the current Low Pressure setting.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 9.5 Testing High Duty Cycle Alarm NOTE: All testing values are based on default Dehydrator settings, if settings have been changed, adjust testing values accordingly. 9.5.1 Press the HOLD Button on PRESSURE Screen.
Page 68
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 9.5.4 Reconnect air supply line to Dehydrtator. 9.5.5 Press the RESET Button to clear the alarm. If you are unable to create a Duty Cycle Alarm as described, see Section 11.13 for troubleshooting information.
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 10. Service & Repair Only PUREGAS can offer factory direct rebuilds backed by a 6 month factory warranty. 2 week turnaround time Estimates available upon request Minimum service charge fee applies 10.1 Services Offered...
PLEASE READ THIS SECTION FIRST. It is important that you use the following sections in order to diagnose and attempt to fix the problem with your Dehydrator before placing a call to PUREGAS Technical Support. This troubleshooting guide is intended to simplify the isolation of problems, present possible causes, provide test procedures for verification, and suggest corrective actions to restore the Dehydrator back to normal operation.
Page 71
Incoming power to Dehydrator must be: 10 amp service recommended 24 VDC for P200W2 model (7 Amp slow blow fuse) 48 VDC for P208W2 model (7 amp slow blow fuse) 85 - 264 VAC, 1 Phase for P200WA2 model...
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 11.3 Dehydrator Won’t Power ON Possible Cause Check Corrective Action POWER Button in Verify POWER Button Move POWER Button OFF position is in ON position to ON position (Section 8.3 ) (Section 8.3 )
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 11.6 Can’t Create a High Pressure Alarm Possible Cause Check Corrective Action High Pressure Alarm set Verify High Pressure Adjust High Pressure point higher than default Alarm set point Setting so that the setting (Section 8.8.2 )
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 11.8 Can’t Create a Low Pressure Alarm Possible Cause Check Corrective Action Low Pressure Alarm set Verify Low Pressure Adjust Low Pressure point lower than default Alarm set point Setting so that the setting (Section 8.8.4 )
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 11.12 Duty Cycle Alarm Possible Cause Check Corrective Action Air leaks in pressurized Verify that air supply Repair or seal all air system line and waveguide have leaks. no leaks. 11.13 Can’t Create a Duty Cycle Alarm...
(Section 11.16 ) 11.16 Contacting PUREGAS Technical Support Please read the Before You Call PUREGAS Section 11.1 Once you have exhausted all of the potential problems and solutions covered in the Troubleshooting Your Dehydrator Section, and you still require further assistance to...
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 12. Appendix 12.1 Set Point Limits and Defaults 12.1.1 System Operations Minimum Maximum Default Unit of Description Value Value Value Measurement High Pressure Limit – 55.2 10.3 Turn Compressor OFF Low Pressure Limit –...
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide 12.2 SNMP Parameters Device Configuration Information Device ID Alphanumeric (Defined by Customer) Device Model Alphanumeric (Factory Preset) Device Firmware Version Numeric (Factory Preset) Current Date/Time Numeric (mm/dd/yy hh:mm) IP Address Numeric (xxx.xxx.xxx.xxx) Subnet Mask Numeric (xxx.xxx.xxx.xxx)
Page 79
PUREGAS, LLC P200W2 Series Dehydrator User’s Guide Status Readings (Read-Only) cont. HEATER FAILURE Yes / No OVERHEATING Yes / No FAIL TO COOL Yes / No Alarm Readings (Read-Only) High Pressure Alarm OK / Alarm Low Pressure Alarm OK / Alarm...
This warranty shall not apply to any PUREGAS product which shall have been repaired or altered in any way by anyone other than PUREGAS or authorized personnel so as to affect, in our judgment, its proper functioning or reliability, neither will it apply to any product which has been subject to misuse, negligence, or accident.