Summary of Contents for Online Electronics 3014X ATEX
Page 1
3014X ATEX EM TRANSMITTER OPERATING MANUAL CONFIGURATION INFORMATION SERIAL NUMBER: OUTPUT SIGNAL: REPETITION RATE 1: RATE 1 BATTERY LIFE AT +20°C: REPETITION RATE 2: RATE 2 BATTERY LIFE AT +20°C: 3014X ATEX EM TRANSMITTER MANUAL RevB00 Page 1 of 16...
Parameters such as lifetime, pulse rate, frequency, and output level can be customised during manufacture, please contact Online Electronics Ltd for more details. 3014X ATEX EM TRANSMITTER MANUAL RevB00...
O-rings ............... NBR70 (standard) / FKM936 (heavy duty) ATEX: Notified body number....................0891 Type examination number ............... TRAC 09 ATEX 21218 X Code ..................Ex II 2 G Ex d IIB T4..T6X 3014X ATEX EM TRANSMITTER MANUAL RevB00 Page 5 of 16...
To prevent the bleed screw being lost, or the transmitter accidentally being turned back on, the bleed screw should be held in this position with some tape. 3. Use an EM receiver system to confirm that the transmitter has turned off. 3014X ATEX EM TRANSMITTER MANUAL RevB00 Page 6 of 16...
Refer to the front cover of this manual for the expected battery lifetime and ensure that it is adequate for the planned operations. Activate the transmitter as detailed in Section 3.1 TURNING ON. Complete a 3.3 FUNCTION TEST. 3014X ATEX EM TRANSMITTER MANUAL RevB00 Page 7 of 16...
3 full turns to switch the transmitter off and use some tape to hold the bleed screw in this position to prevent it being lost or the transmitter being accidentally turned back on. 3014X ATEX EM TRANSMITTER MANUAL RevB00 Page 8 of 16...
The advantage of these arrangements is that they have limited amounts of metal around the transmitter and will therefore have limited effect on the transmitter performance. Please contact Online Electronics for further information and guidelines regarding EM transmitter mounting and installation.
Typically colder temperatures will shorten the stated lifetime as shown by the figure below. Note that upon customer request, the transmitters can be adjusted at Online Electronics Ltd to provide a stronger signal at the expense of lifetime or extended lifetime at the expense of signal, contact Online Electronics Ltd for more details and to discuss your requirements.
5. Remove all ELECTROCHEM 3B0035-TC Lithium cells and the battery disc. Visually inspect the batteries, contact Online Electronics Ltd immediately if there are any signs of damage or electrolyte leakage. Dispose of the old batteries in a responsible way. Refer to section 3.9 LITHIUM BATTERY SAFETY for further guidance.
The information given in this section is for reference only. It should not be used in place of appropriate local regulations or other legal requirements. Online Electronics Ltd are not responsible for any incident that occurs due to misuse or abuse of their products or misuse or abuse of lithium cells used by their products.
4. Using the supplied ENDCAP REMOVAL TOOL, fully remove the BATTERY ENDCAP, any batteries and the battery disc, then the PCB ENDCAP. 5. Referring to the figure below, remove all O-rings and clean the sealing surfaces on all parts. 3014X ATEX EM TRANSMITTER MANUAL RevB00 Page 13 of 16...
Failure to use such components may invalidate the certification/approval and may make the equipment dangerous. Online Electronics Ltd can supply redress kits containing a complete set of replacement batteries, battery discs, O-rings, O-ring grease, and endcap locking screws, contact Online Electronics Ltd for more information.
ONLINE ELECTRONICS LTD 5. DISPOSAL OF UNIT Online Electronics Ltd (OEL) takes its responsibilities under the WEEE Regulations extremely seriously and has taken steps to be compliant in line with our corporate and social responsibilities. In the UK, OEL has joined a registered compliance scheme WeeeCare (registration number WEE/MP3538PZ/SCH).
2. Warning – Do not open when an explosive atmosphere may be present. 3. Only ELECTROCHEM 3B0035-TC cells are permitted to be used in this equipment. ATEX DIRECTIVE CODE: II 2 G STANDARDS CODE: Ex d IIB T4..T6X 3014X ATEX EM TRANSMITTER MANUAL RevB00 Page 16 of 16...
Need help?
Do you have a question about the 3014X ATEX and is the answer not in the manual?
Questions and answers