Page 1
Drawing : - TPC159 Issue : - 4 Date : - 24/11/16 LD- - - - 82 DEHUMIDIFIER PROCESS DEHUMIDIFIER PROCESS DEHUMIDIFIER PROCESS DEHUMIDIFIER PROCESS DRYER DRYER DRYER DRYER (1320500) (1320500) (1320500) (1320500) OWNER’S MANUAL OWNER’S MANUAL OWNER’S MANUAL OWNER’S MANUAL www.eipl.co.uk Page 1 of 12...
Page 2
Ask for the Ebac Technical Publication (TP 132), “Wood Drying with the Ebac range of small scale wood dryers” The LD-82 dehumidifier process dryer removes moisture from the air that is circulating through the unit. The LD-82 dehumidifier process dryer requires no previous experience with drying as it is simple to install and operate.
Page 3
: - 4 Date : - 24/11/16 The LD-82 dehumidifier process dryer consists of a motor-compressor unit, a refrigerant condenser, air circulating fans, a refrigerated surface, and a means of collecting and disposing the condensed moisture and a cabinet to house these components.
INSTALLATION POSITIONING: Position the LD-82 dehumidifier process dryer in the chamber as shown and instructed (see TP 132). It is advisable to ensure that access can be made to the process drying unit even when the entire product to be dried is in place.
AIR MOVING SYSTEM: Air is drawn into the LD-82 dehumidifier process unit at the base of the dehumidifier and over the two heat exchanges (evaporator/condenser coils) under the influence of the axial fan, which is driven by the motor. The operation of the fan motor is to run continuously whenever power is supplied to the dehumidifier.
Page 7
Drawing : - TPC159 Issue : - 4 Date : - 24/11/16 WARNING: • Due to the high pressures within the refrigeration circuit, under no circumstances must direct heat be applied to the evaporator coil in an attempt to remove the build up of ice. •...
Drawing : - TPC159 Issue : - 4 Date : - 24/11/16 ROUTINE SERVICE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON.
Page 9
Drawing : - TPC159 Issue : - 4 Date : - 24/11/16 REPAIRS Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault.
Drawing : - TPC159 Issue : - 4 Date : - 24/11/16 LD-82 SPARE PARTS LIST ESCRIPTION UMBER Product Part Number 1320500 Compressor 3022142 Compressor OH Protector 3021529 Compressor Start Relay 3021530 Compressor Start Capacitor 3021531 Condenser Coil 3020740 Evaporator Coil...
Page 11
Drawing : - TPC159 Issue : - 4 Date : - 24/11/16 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved.