Advertisement

Quick Links

testo ASET15 1
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASET15 1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TESTO ASET15 1

  • Page 1 ASET15 1 User Manual...
  • Page 3: Table Of Contents

    5.1. Integrating testo MD19-3E into the testo ASET15-1 ..............14 5.2. Gas/Aerosol Connections ......................15 5.2.1. Quick Couplings at the front of testo ASET15-1 ..............15 5.2.2. Connect a Sensor to the Measuring Gas Inlet of the Evaporation Tube ........ 15 Operating Instructions ....................
  • Page 4 Appendix ........................24 9.1. Extent of Delivery ........................24 9.2. Specification, Technical Data ......................24 9.3. Thermophoretic Losses ........................ 25 9.4. Definitions, Units and Conversion Table ..................26 Designation of All testo ASET15-1 Air Supply / Evaporation Tube Elements ....27...
  • Page 5: Declaration Of Warranty

    Only the original manufacturer's warranty applies. There are no user-serviceable parts inside testo ASET15-1 and some very sensitive parts. Do not open your testo ASET15-1, as you may damage it. Warranty is voided if the case is opened and warranty-seal is broken.
  • Page 6: Liability To Content

    2.2.1. Liability to Content The content of this manual is generated with most accurateness. Testo SE & Co. KGaA does not guarantee completeness, correctness and being up to date. Testo SE & Co. KGaAreserves the right to revise the content of the manual at any time and without notice.
  • Page 7: Labels And Explanations

    3.2. Labels and Explanations When operating the testo ASET15-1, the user always is operating under certain risk factors as electricity, hot surfaces, and the aerosols which are processed by the dilution and conditioning system. Therefore the testo ASET15-1 includes several safety features. Nevertheless, some precautions still need to be taken to ensure safe and reliable operation.
  • Page 8: System Overview

    Dilution and Conditioning 4.1.1. Principle testo ASET15-1 Air Supply / Evaporation Tube is an accessory for the testo MD19 which is the Rotating Disk Diluter with external diluter head for performing the primary dilution as close as possible to the aerosol source.
  • Page 9: Definitions

    Dilution Factor in secondary dilution: DF = (Q )/ Q PCRF Particle Concentration Reduction Factor Light Emitting Diode – used as signal lamps at the front of the testo ASET15-1 l/min (STP) Standard liter per minute: unit for gas volume flow at Standard Temperature and Preasure (STP: 1013,25 hPa, 0°C)
  • Page 10: The System

    39 Heat sink The testo ASET15-1 is power supplied by one phase electricity. An internal pump feeds filtered air to the integrated testo MD19-3E, where raw gas is added and therewith primary dilution is carried out. The testo ASET15-1 Air Supply / Evaporation Tube with integrated testo MD19-3E...
  • Page 11: Control Elements And Connections

    ASET15-1 and the testo MD19-3E. The pathways of dilution air, raw gas and diluted measuring gas are visible. No external dilution air is needed. Ambient air is drawn and filtered inside the case of the testo ASET15-1 and fed to the testo MD19-3E where it is needed to dilute some raw gas. The primarily diluted gas then returns to the testo ASET15-1.
  • Page 12: Gas Connectors

    4.5.3. Gas Connectors The excess gas port 12) and measuring gas port 13) of testo ASET15-1 can be connected to an offtake and to the subsequent sensor(s) using the connectors shown in Fig. 4.4. Fig.4.4 : excess and measuring gas connectors...
  • Page 13: Rear View

    4.5.4. Rear View Fig. 4.5 and 4.6 show all testo ASET15-1 elements and connections which are situated at the rear side of the unit. The hot parts are covered by a safety protection cage which has been removed in Fig. 4.6.
  • Page 14: Installation And Setup

    The control unit of the primary diluter is plugged into the testo ASET15-1 housing and fixed with six screws located at the top and the bottom of the testo MD19-3E front panel. To remove the testo MD19-3E from the testo ASET15-1 these screws have to be solved and the unit can be pulled out.
  • Page 15: Gas/Aerosol Connections

    5.2.1. Quick Couplings at the front of testo ASET15-1 testo ASET15-1 is equipped with two quick coupling elements to connect the device to an excess gas offtake (male coupling 12)) and to the subsequent sensor(s) (female coupling 13)). One female excess gas coupling 22) is included in testo ASET15-1 delivery and one male measuring gas plug 23) is delivered with testo MD19-3E rotating disk diluter.
  • Page 16: Operating Instructions

    ASET15-1 follow these steps:  Connect the connector 31) at the rear side of the testo ASET15-1 case to mains supply. The mains switch 30) should remain switched off. Details of the power supply are described in chapter 7.
  • Page 17: Flows And Control Led's In Air Supply Part

    Q are mixed in the secondary dilution mixing chamber 37). Fig. 6.2 shall help to understand the setting of the secondary dilution air in the air supply part of testo ASET15-1. Fig.6.2: secondary dilution flows Measuring gas flow Q (standard 1.5 l/min) from the testo MD19-3E Rotating Disk Diluter enters...
  • Page 18: Signal Led Information

    1.5 l/min. This amount of filtered dilution air is fed to the inserted primary diluter testo MD19-3E. It is added there by some raw gas and returns then to the testo ASET15-1 for further conditioning.
  • Page 19: Remote Operation

    Besides the remote interface of the integrated testo MD19-3E Rotating Disk Diluter is connected to the corresponding plug 26) at the rear side of the testo ASET15-1 case. The function and pin assignment of this connector are the same as the ones of the connector at the rear side of the...
  • Page 20: Electrical Connections

    Connect the power cord plug to a grounded power socket. The IEC mains connector 31) on the rear side of the testo ASET15-1 case includes the mains switch 30). The fuse holders 28) and 29) for integrated testo MD19-3E Rotating Disk Diluter and testo ASET15-1 itself are located on the rear side of the laboratory case, besides the mains switch / mains connector.
  • Page 21 4) 0 VDC: OFF 5 VDC: ON ON/OFF 10 not connected actual testo MD19 -3E dilution fixed value within air flow (1.5 l/min) 3.2...3.8 VDC 0 VDC: local 5 VDC: 12 remote operation...
  • Page 22: Remote Control

    LED 5).  If the testo MD19-3E air supply LED 7) remains red for longer than a few seconds after the pump is switched on it indicates insufficient dilution air flow either caused by a testo MD19-3E air supply pump defect or an overloaded testo MD19-3E air supply filter.
  • Page 23: Operation Environment Requirements

    Operation Environment Requirements Caution Read this section carefully before setting up testo ASET15-1 Air Supply / Evaporation Tube. Testo SE & Co. KGaA is not liable if the instrument is damaged, caused by the operation environment not meeting the requirements. Caution The testo ASET15-1 Air Supply / Evaporation Tube is designed to be installed in a laboratory, test stand or a temporary test set-up.
  • Page 24: Appendix

    0.3 l/min power supply 90...240 VAC, 50/60 Hz, max. 600 VA with integrated testo MD19-3E local operation primary dilution air supply pump switch, secondary air supply pump switch, scaled 10-turn secondary dilution setting potentiometer, evaporation tube switch, evaporation tube temperature control panel, LED indicators •...
  • Page 25: Thermophoretic Losses

    34) and enters the mixing chamber 37). The diagram in Fig. A.1 shows the typical thermophoretic losses in the evaporation tube heated up to 300°C measured on testo ASET15-1 with 82 nm soot particles. Each testo ASET15-1 is calibrated individually for most accurate loss determination.
  • Page 26: Definitions, Units And Conversion Table

    9 Appendix 9.4. Definitions, Units and Conversion Table Pressure Pascal Pound per square inch (Pa) (bar) (psi) 1 Pa 1.0 · 10 1.450 · 10 1 bar 1.0 · 10 14.504 1 psi 6 894.8 0.0689 Micromete Length Meter Centimeter Millimeter Nanometer Inch (μm) (cm)
  • Page 27: Designation Of All Testo Aset15-1 Air Supply / Evaporation Tube Elements

    20 Temperature controller status field 21 Temperature controller control field 22 Male gas coupling for connecting a 6 mm ID tube to measuring gas port (delivered with testo MD19-3E Rotating Disk Diluter) 23 Female gas coupling for connecting a 6 mm ID tube to excess gas port...
  • Page 28 10 Designation of All testo ASET15-1 Air Supply / Evaporation Tube Elements 36 Secondary dilution air inlet 37 Secondary dilution mixing chamber 38 ET temperature sensor 39 Heat sink 40 Connection between mixing chamber and heat sink 39) 41 Fan for cooling the components integrated in the testo ASET15-1...
  • Page 30 Testo SE & Co. KGaA Testo-Strasse 1 79853 Lenzkirch Germany phone: +49 7653 681 5062 fax: +49 7653 681 95062 e-mail: sales-nanoparticle@testo.de...

Table of Contents