NEW SUNRISE NVR-1000 User Manual

NEW SUNRISE NVR-1000 User Manual

Vhf radiotelephone

Advertisement

NVR-1000
VHF RADIOTELEPHONE
USER'S MANUAL
NEW SUNRISE
NVR-1000 OM.E 20130216-002

Advertisement

Table of Contents
loading

Summary of Contents for NEW SUNRISE NVR-1000

  • Page 1 NVR-1000 VHF RADIOTELEPHONE USER’S MANUAL NEW SUNRISE NVR-1000 OM.E 20130216-002...
  • Page 2 Please read this manual carefully to ensure proper use before installation and use of the NVR-1000. Please keep the manual for your future reference. NVR-1000 OM.E 20130216-002...
  • Page 3 NVR-1000 MANUAL Some Frequently Asked Questions How to check out own ship’s MMSI? Own ship’s MMSI will show up shortly when the NVR-1000 is powered on. You may also check out the MMSI in “DIAGNOSTICS”. How to setup own ship’s MMSI? The MMSI can be entered in SUPERVISION----MMSI SETUP.
  • Page 4 Don’t open the equipment unless you have fully understood the structure and circuits of the equipment. Only qualified personnel should work inside the equipment. Don’t disassemble or try to modify the equipment. Dangerous Turn off the power at power distribution board before installation. NVR-1000 OM.E 20130216-002...
  • Page 5: Table Of Contents

    7. DSC CALLS ....................... 12 7.1 MAKE A DSC CALL ..................12 7.1.1 DISTRESS CALL ..................12 7.1.2 URGENCY CALL ..................14 7.1.3 SAFETY CALL ..................16 7.1.4 ROUTINE CALL ..................17 7.1.5 SEMI / AUTO VHF ................... 19 NVR-1000 OM.E 20130216-002...
  • Page 6 Appendix Ⅰ. CHANNEL TABLE ................25 ITU Channel Table ......................25 USA Channel Table ......................26 CAN Cannel Table ......................27 Private Channel (simplex) ....................28 WX (Weather) Channel Table ..................29 Appendix Ⅱ. INSTALLATION DRAWINGS ............30 NVR-1000 OM.E 20130216-002...
  • Page 7: Overview

    NVR-1000 MANUAL 1. OVERVIEW NVR-1000 is a ship borne radiotelephone equipment on VHF FM and designed for marine mobile service which provides function of VHF radiotelephone and digital selective calling. It is to be met by provision of GMDSS required as 1988 GMDSS amendments to SOLAS 1974.
  • Page 8: Configurations

    2. CONFIGURATIONS 2.1 SYSTEM CONFIGURATIONS The below figure is for the configurations of the equipment. 2.2 SUPPLY SCOPE ITEM Q’TY REMARKS Standard NVR-1000 VHF RADIOTELEPHONE NVR-1030H MICROPHONE FITTING MATERIALS USER’S MANUAL Optional VHF ANTENNA THERMAL PRINTER NPT-100 VDR CONNECTION KIT...
  • Page 9: Specifications

    3.3 RECEIVER ≤2uV e.m.f (SINAD=20dB) Sensitivity ≥70dB Adjacent selectivity ≥40dB ( 1kHz, 70% modulated, 30dBμV RF input) Signal to noise ratio ≥70dB Spurious response rejection ≤2nW (9kHz~2GHz) Spurious emission ≥65dB Intermodulation rejection ≤10% Harmonic distortion Max Audio output NVR-1000 OM.E 20130216-002...
  • Page 10: Dsc Function

    MARK(signal Y ) : 1,300Hz ± 10Hz SPACE(signal B ) : 2,100Hz ± 10Hz Transmission speed 1,200bps ± 30 x 10 3.5 DEDICATED DSC RECEIVER (WKR) Receive frequency 156.525MHZ (channel 70) Sensitivity Error rate≤1% when receiving signal=1μV NVR-1000 OM.E 20130216-002...
  • Page 11: Starting System

    NVR-1000 MANUAL 4. STARTING SYSTEM 4.1 POWER ON To start NVR-1000, follow the below steps: ① Power on the equipment by turning power switch (volume switch) clockwise. ② If the equipment is switched on initially, program will be booted and it requires for MMSI input as in right figure, then press ESC to return to the initial screen and enter MMSI.
  • Page 12: Basic Operation

    Note: if squelch level is too high, weak signal could be ignored. Press F Key and then press ▲ or ▼ to DIMMER change the LCD backlight. TX POWER Set the transmitting power 25W or 1W. NVR-1000 OM.E 20130216-002...
  • Page 13: Basic Operation

    0.15s on CH16 every 2s when receiving on the additional channel. Whenever a signal is detected on CH16 during sampling, the transceiver will stay on CH16 for receiving, by ignoring the signal on the additional channel. NVR-1000 OM.E 20130216-002...
  • Page 14: Initial Setup

    If a GPS receiver is connected, current position will be updated automatically. But if the GPS receiver is not connected or the GPS data is not available, position data should be entered manually. Input current position manually in the same way with time setting. NVR-1000 OM.E 20130216-002...
  • Page 15: Others Setup

    (Brightness is adjustable by using “F” key and up/down key in the initial screen.) 6.4 DIAGNOSTICS  It is to check own ship’s MMSI or current software version.  It is to check own ship’s MMSI and group ID and modification is not allowed here. NVR-1000 OM.E 20130216-002...
  • Page 16: Supervision

    Own ship’s MMSI is individual MMSI assigned to the vessel by the authority. GROUP 1 & GROUP 2 MMSIs are special for group DSC calling. Usually local administration can define such group MMSI for certain vessels for safety concern. Both group MMSIs can leave empty if unavailable. NVR-1000 OM.E 20130216-002...
  • Page 17 GROUP 1: 012345678 3. FACTORY DEFAULT GROUP 2: 012345678 - TEST SIGNAL Such test signal is used to diagnose the DSC facility within the equipment. SUPERVISION 1. MMSI SETUP > 2. TEST SIGNAL 3. FACTORY DEFAULT Select Enter. NVR-1000 OM.E 20130216-002...
  • Page 18: Dsc Calls

    The position data is included in the message. When a GPS receiver is connected, the position will be updated automatically, otherwise the manual input is required. Send the call when completed. The distress call is sent to all vessels. NVR-1000 OM.E 20130216-002...
  • Page 19 It is to relay a distress call to all vessels. - RELAY –A STATION It’s to relay a distress call to a station. A particular MMSI is entered before send the call. - RELAY ACK It’s to acknowledge a distress relay. NVR-1000 OM.E 20130216-002...
  • Page 20: Urgency Call

    In the TO ALL SHIPS menu, select ALL MODE TP. SEND DSC FORMAT : INDIVIDUAL TO : 987654321 CATEGORY : URGENCY FROM : 123456789 ALL MODES TP NO INFORMATION RX CH NO : 0006 ↓ In the TO ALL SHIPS menu, select MEDICAL X-PORTS. NVR-1000 OM.E 20130216-002...
  • Page 21 ALL MODES TP MEDLCAL X-PORTS 0006↓ In the TO ALL SHIPS menu, select SHIPS&AIRCRAFT. SEND DSC FORMAT : ALL SHIPS TO : ALL SHIPS CATEGORY : URGENCY FROM : 123456789 ALL MODES TP SHIP&AIRCRAFT 0006↓ Select TO A STATION. NVR-1000 OM.E 20130216-002...
  • Page 22: Safety Call

    FROM : 123456789 ALL MODE TP NO INFORMATION RX CH NO : 6↓ Select TO A STATION. In the TO A STATION menu, there are three options, ALL MODE TP, POSITION REQUEST and TEST. Select ALL MODE TP. NVR-1000 OM.E 20130216-002...
  • Page 23: Routine Call

    NVR-1000 MANUAL Select POSITION REQUEST. Select TEST. 7.1.4 ROUTINE CALL It is same as URGENCY CALL. Select TO SHIPS GROUP. Select TO A STATION. NVR-1000 OM.E 20130216-002...
  • Page 24 NVR-1000 MANUAL Select ALL MODE TP in the TO A STATION. Select DATA. Select POLLING. NVR-1000 OM.E 20130216-002...
  • Page 25: Semi / Auto Vhf

    Enter the telephone number you want to talk to. The user is required to consult with coast station for right calling procedure before make such SEMI/AUTO phones. Confirm contents of message to be sent, press “ENT” key to transmit. NVR-1000 OM.E 20130216-002...
  • Page 26: Transmit A Stored Dsc Message

    If received DSC message is indicated in LCD, press “ESC” then main screen will be displayed in LCD and processing of received DSC message would be stored once and held. Reserved message could be confirmed in DSC menu showed by pressing DSC key. NVR-1000 OM.E 20130216-002...
  • Page 27: Distress Call

    • MAN OVERBOARD • EPIRB EMISSION 7.3.2 URGENCY CALL → TO ALLSHIPS CHANNEL NO. → ALL MODE TP CHANNEL NO. → MEDICAL X-PORT CHANNEL NO. → SHIP & AIRCRAFT CHANNEL NO. → → TO A STATION MMSI CHANNEL NO. NVR-1000 OM.E 20130216-002...
  • Page 28: Safety Call

    TO ALL SHIPS → GROUP →MMSI→ CHANNEL NO. ALLMODE TP → MMSI → CHANNEL NO. TO A STATION DATA→ MMSI→CHANNEL NO. POLLING→ MMSI→CHANNEL NO. 7.3.5 SEMI / AUTO VHF ALL MODE TP → MMSI → WORKING CHANNEL→TELEPHONE NO. DATA→MMSI→ WORKING CHANNEL →TELEPHONE NO. NVR-1000 OM.E 20130216-002...
  • Page 29: Installation

    Especially, sharp bending of the RF cable must be avoided. 8.3 CONNECTION 8.3.1 POWER SUPPLY The power cable with a rated capacity of 10A should be used. Suggest using the 10A DC Power Supply Unit (DC13.5V output). NVR-1000 OM.E 20130216-002...
  • Page 30: Gps Data Input

    - Baud rate setting NPT-100’s baud rate can be 75, 110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200bps. As the default rate, both NVR-1000 and NPT-100 have been set at 4800bps in factory. 8.3.4 CONNECT TO (S)VDR NVR-1000 outputs RX AUDIO/pin2 and TX AUDIO/pin6. Optional connection box NVC100 is needed to output balanced audio signals for (S)VDR.
  • Page 31: Appendix Ⅰ. Channel Table

    156.525 156.575 156.575 156.625 156.625 156.675 156.675 156.725 156.725 156.775 156.775 156.825 156.825 156.875 156.875 156.925 161.525 156.975 161.575 157.025 161.625 157.075 161.675 157.125 161.725 157.175 161.775 157.225 161.825 157.275 161.875 157.325 161.925 157.375 157.375 157.425 157.425 NVR-1000 OM.E 20130216-002...
  • Page 32: Usa Channel Table

    156.950 156.525 156.525 157.000 157.000 156.575 156.575 156.625 156.625 156.675 156.675 156.725 156.725 156.875 156.875 156.925 156.925 156.975 156.975 157.025 157.025 157.075 157.075 157.125 157.125 157.175 157.175 157.225 161.825 157.275 161.875 157.325 161.925 157.375 157.375 157.425 157.425 NVR-1000 OM.E 20130216-002...
  • Page 33: Can Cannel Table

    161.600 156.575 156.575 156.625 156.625 156.675 156.675 156.725 156.725 156.775 156.775 156.825 161.425 156.875 156.875 156.925 161.525 156.975 161.575 157.025 161.625 157.075 161.675 157.125 161.725 157.175 161.775 157.225 161.825 157.275 161.875 157.325 161.925 157.375 157.375 157.425 157.425 NVR-1000 OM.E 20130216-002...
  • Page 34: Private Channel (Simplex)

    158.075 159.225 158.125 159.275 158.175 159.325 158.225 159.375 158.275 159.425 158.325 159.475 158.375 159.525 158.425 159.575 158.475 159.625 158.525 159.675 158.575 159.725 158.625 159.775 158.675 159.825 158.725 159.875 158.775 158.825 158.875 158.925 158.975 159.025 159.075 159.125 159.175 NVR-1000 OM.E 20130216-002...
  • Page 35: Wx (Weather) Channel Table

    NVR-1000 MANUAL WX (Weather) Channel Table Freq.( MHz) WX01 162.550 WX02 162.400 WX03 162.475 WX04 162.425 WX05 162.450 WX06 162.500 WX07 162.525 WX08 161.650 WX09 161.775 WX10 163.275 NVR-1000 OM.E 20130216-002...
  • Page 36: Appendix Ⅱ. Installation Drawings

    NVR-1000 MANUAL Appendix Ⅱ. INSTALLATION DRAWINGS NVR-1000 OM.E 20130216-002...

Table of Contents