Page 3
NVR-1000 MANUAL Some Frequently Asked Questions How to check out own ship’s MMSI? Own ship’s MMSI will show up shortly when the NVR-1000 is powered on. You may also check out the MMSI in “DIAGNOSTICS”. How to setup own ship’s MMSI? The MMSI can be entered in SUPERVISION----MMSI SETUP.
Page 4
Don’t open the equipment unless you have fully understood the structure and circuits of the equipment. Only qualified personnel should work inside the equipment. Don’t disassemble or try to modify the equipment. Dangerous Turn off the power at power distribution board before installation. NVR-1000 OM.E 20130216-002...
NVR-1000 MANUAL 1. OVERVIEW NVR-1000 is a ship borne radiotelephone equipment on VHF FM and designed for marine mobile service which provides function of VHF radiotelephone and digital selective calling. It is to be met by provision of GMDSS required as 1988 GMDSS amendments to SOLAS 1974.
2. CONFIGURATIONS 2.1 SYSTEM CONFIGURATIONS The below figure is for the configurations of the equipment. 2.2 SUPPLY SCOPE ITEM Q’TY REMARKS Standard NVR-1000 VHF RADIOTELEPHONE NVR-1030H MICROPHONE FITTING MATERIALS USER’S MANUAL Optional VHF ANTENNA THERMAL PRINTER NPT-100 VDR CONNECTION KIT...
NVR-1000 MANUAL 4. STARTING SYSTEM 4.1 POWER ON To start NVR-1000, follow the below steps: ① Power on the equipment by turning power switch (volume switch) clockwise. ② If the equipment is switched on initially, program will be booted and it requires for MMSI input as in right figure, then press ESC to return to the initial screen and enter MMSI.
Note: if squelch level is too high, weak signal could be ignored. Press F Key and then press ▲ or ▼ to DIMMER change the LCD backlight. TX POWER Set the transmitting power 25W or 1W. NVR-1000 OM.E 20130216-002...
0.15s on CH16 every 2s when receiving on the additional channel. Whenever a signal is detected on CH16 during sampling, the transceiver will stay on CH16 for receiving, by ignoring the signal on the additional channel. NVR-1000 OM.E 20130216-002...
If a GPS receiver is connected, current position will be updated automatically. But if the GPS receiver is not connected or the GPS data is not available, position data should be entered manually. Input current position manually in the same way with time setting. NVR-1000 OM.E 20130216-002...
(Brightness is adjustable by using “F” key and up/down key in the initial screen.) 6.4 DIAGNOSTICS It is to check own ship’s MMSI or current software version. It is to check own ship’s MMSI and group ID and modification is not allowed here. NVR-1000 OM.E 20130216-002...
Own ship’s MMSI is individual MMSI assigned to the vessel by the authority. GROUP 1 & GROUP 2 MMSIs are special for group DSC calling. Usually local administration can define such group MMSI for certain vessels for safety concern. Both group MMSIs can leave empty if unavailable. NVR-1000 OM.E 20130216-002...
Page 17
GROUP 1: 012345678 3. FACTORY DEFAULT GROUP 2: 012345678 - TEST SIGNAL Such test signal is used to diagnose the DSC facility within the equipment. SUPERVISION 1. MMSI SETUP > 2. TEST SIGNAL 3. FACTORY DEFAULT Select Enter. NVR-1000 OM.E 20130216-002...
The position data is included in the message. When a GPS receiver is connected, the position will be updated automatically, otherwise the manual input is required. Send the call when completed. The distress call is sent to all vessels. NVR-1000 OM.E 20130216-002...
Page 19
It is to relay a distress call to all vessels. - RELAY –A STATION It’s to relay a distress call to a station. A particular MMSI is entered before send the call. - RELAY ACK It’s to acknowledge a distress relay. NVR-1000 OM.E 20130216-002...
In the TO ALL SHIPS menu, select ALL MODE TP. SEND DSC FORMAT : INDIVIDUAL TO : 987654321 CATEGORY : URGENCY FROM : 123456789 ALL MODES TP NO INFORMATION RX CH NO : 0006 ↓ In the TO ALL SHIPS menu, select MEDICAL X-PORTS. NVR-1000 OM.E 20130216-002...
Page 21
ALL MODES TP MEDLCAL X-PORTS 0006↓ In the TO ALL SHIPS menu, select SHIPS&AIRCRAFT. SEND DSC FORMAT : ALL SHIPS TO : ALL SHIPS CATEGORY : URGENCY FROM : 123456789 ALL MODES TP SHIP&AIRCRAFT 0006↓ Select TO A STATION. NVR-1000 OM.E 20130216-002...
FROM : 123456789 ALL MODE TP NO INFORMATION RX CH NO : 6↓ Select TO A STATION. In the TO A STATION menu, there are three options, ALL MODE TP, POSITION REQUEST and TEST. Select ALL MODE TP. NVR-1000 OM.E 20130216-002...
NVR-1000 MANUAL Select POSITION REQUEST. Select TEST. 7.1.4 ROUTINE CALL It is same as URGENCY CALL. Select TO SHIPS GROUP. Select TO A STATION. NVR-1000 OM.E 20130216-002...
Page 24
NVR-1000 MANUAL Select ALL MODE TP in the TO A STATION. Select DATA. Select POLLING. NVR-1000 OM.E 20130216-002...
Enter the telephone number you want to talk to. The user is required to consult with coast station for right calling procedure before make such SEMI/AUTO phones. Confirm contents of message to be sent, press “ENT” key to transmit. NVR-1000 OM.E 20130216-002...
If received DSC message is indicated in LCD, press “ESC” then main screen will be displayed in LCD and processing of received DSC message would be stored once and held. Reserved message could be confirmed in DSC menu showed by pressing DSC key. NVR-1000 OM.E 20130216-002...
TO ALL SHIPS → GROUP →MMSI→ CHANNEL NO. ALLMODE TP → MMSI → CHANNEL NO. TO A STATION DATA→ MMSI→CHANNEL NO. POLLING→ MMSI→CHANNEL NO. 7.3.5 SEMI / AUTO VHF ALL MODE TP → MMSI → WORKING CHANNEL→TELEPHONE NO. DATA→MMSI→ WORKING CHANNEL →TELEPHONE NO. NVR-1000 OM.E 20130216-002...
Especially, sharp bending of the RF cable must be avoided. 8.3 CONNECTION 8.3.1 POWER SUPPLY The power cable with a rated capacity of 10A should be used. Suggest using the 10A DC Power Supply Unit (DC13.5V output). NVR-1000 OM.E 20130216-002...
- Baud rate setting NPT-100’s baud rate can be 75, 110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200bps. As the default rate, both NVR-1000 and NPT-100 have been set at 4800bps in factory. 8.3.4 CONNECT TO (S)VDR NVR-1000 outputs RX AUDIO/pin2 and TX AUDIO/pin6. Optional connection box NVC100 is needed to output balanced audio signals for (S)VDR.