Kestrel Pocket Weather Tracker Instruction Manual page 5

With horus atragtm ballistic calculator
Table of Contents

Advertisement

GUN
Laru308
MV
1360f
s
p
BC
0.470
BW
175
r
g
BD
0.308in
Figure 1
• In cases where the bullet is supersonic, there are no
dots next to the muzzle velocity value.
MV-Temp Table
This allows you to enter and maintain a table of muzzle
velocities based on temperature. If an entry is input
into the table, the muzzle velocity is applied at all
temperatures (this means that the value is then locked
and cannot be altered by using
information screen) If two or more entries are input
into the table, the Kestrel uses the linear interpolation
and the temperature sensor to determine the appropri-
ate muzzle velocity (Note: this value will only change
if the temperature changes and you exit and re-enter
the gun information screen; once a muzzle velocity
value is entered for a particular temperature, you can
not make another muzzle velocity value for the same
temperature.)
• To access MV-Temp table, scroll to MV (Muzzle
Velocity) to highlight it and press
to scroll to MV-Temp and press
Muzzle velocity
MV
feet
er sec
p
MV-Tem
p
Shop for Kestrel products online at:
GUN
Laru308
MV
1103f
s
p
BC
0.470
BW
175
r
g
BD
0.308in
Figure 2
and
on the gun
, then use
to enter.
2900
f
s
p
WeatherMeters-Direct
www.
• Press
while "New entry" is highlighted to enter
the Table Item screen.
• Use
or
and
to adjust each value.
Table item
Tem
p
MV
Clear
• To clear a Table Item, scroll down to Clear and
press
.
• Press
to exit to return to the Gun Information
screen.
BC-Dist Table
This allows you to enter and maintain a table of ballistic
coefficients based on distance. If only one entry is input
into the table, the ballistic coefficient is applied at all
distances (this means that the value is locked and cannot
be altered by using
and
more entries are input into the table, the Kestrel uses the
linear interpolation and the target range to determine the
appropriate ballistic coefficient (Notes: this value will only
change if the target range changes; once a ballistic coef-
ficient value is entered for a particular distance, you cannot
make another ballistic coefficient value for the
same distance.)
• To access the BC-Dist table, scroll to BC (Ballistic
Coefficient) to highlight it and press
to scroll to BC-Dist and press
1.877.766.5412
.ca
to scroll to "Temp" and "MV". Use
10ºF
2900
f
s
p
on the gun screen). If two or
, then use
to enter.
9

Advertisement

Table of Contents
loading

Table of Contents