Page 2
To the best of our knowledge and belief, the information contained in this manual is true and correct as of the date of publication. The contents, however, do not constitute a binding obligation on the part of Regloplas AG and are subject to change without notice.
Operation with Timer ................10 Alarm Reset and Alarm History ..............10 Save/Reset of the Setting Values ............10 RT100 Control System - Loading firmware/bootloader ......... 11 USB flash drive ..................11 Loading the firmware/bootloader ............. 12 ...
Page 4
Service menu ......................39 Multiflow ........................ 39 Data Interfaces Basic Concept ...................... 41 Protocols ....................... 41 Plug Nomenclature RT100 Front panel ....................43 RT100 Base Module ..................... 43 ii Contents RT100 Control System...
Page 5
RT100 Analog Option ................... 46 Digital Functions ..................46 Analog Functions ..................47 RT100 Option Reversal of Direction of Rotation >9A ........... 47 RT100 Option Current Monitoring Heating ............47 Hardware RT100 Front Panel - Layout .................. 49 ...
Failure to heed the information can result in property damage as well as minor or moderate personal injury! NOTE Denotes general information, useful advice to users and work recommenda- tions, which, however, do not have any influence on the safety and health of personnel. General Safety Information 1 RT100 Control System...
Regloplas. Intended Use The Regloplas control system is built according to the current state of the art and the generally accepted principles of safety engineering. The con- trol system is intended solely for the normal use for heating and/or cool- ing of injection and die casting moulds, extruders, calenders, mixers and other consumers in areas in which there is no risk of explosion.
If the temperature control unit is damaged, it must not remain in use; the defective part must be replaced or repaired immediately. Only original Regloplas replacement parts may be used. Damage due to use of third- party parts voids any and all warranty claims.
The corresponding additional doc- uments are included with special versions of devices. Any additional doc- uments supplement and/or replace the descriptions contained in these instructions, which are then either invalid or only conditionally valid. 4 General Safety Information RT100 Control System...
No external, third-party devices may be connected to the 24 VDC supply and the AC supply of the base module! Operation Concept The RT100 Control System is equipped with an RCD control knob. It can be used for navigation in the user interface through simple rotating and pressing.
Selection of the device functions Symbol area RCD control knob Status LEDs (Regloplas Control Dial) RT100 Control System - front panel Buttons Setting the set-point value Scrolling through pages Setting the additional display Setting the parameters Selection of the device functions (toggling...
RT100 Control System - Displays Operation and Status Displays In the off state of the RT100 Control System, the message OFF appears in the display area. Upon switching on with the button ON/OFF, the addi- tional display is shown. The top left part of the display shows the set- point temperature SP1 or SP2 (SP = Set point).
Powering Up Upon switching on the main switch, OFF appears in the display. The RT100 Control System is now ready for operation and is switched on by pressing the ON/OFF button, or by the timer, through a digital input or an interface.
In the case of pressurised water units, the pressure release valve closes 5 °C above the run-on temperature value (max. 85 °C) and opens at the programmed run-on temperature value during the cooling process. Design and Function 9 RT100 Control System...
It is earnestly recommended that an operator password should be set up when commissioning the temperature control device. Operation with Timer The RT100 Control System has an integrated real-time clock. If the op- tion Timer is present, the device can be switched on and off with this op- tion.
V 01/2016 RT100 Control System - Loading firmware/bootloader USB flash drive The empty USB flash drive must be formatted with FAT file sys- tem (see below) The firmware must be extracted from the compressed file and copied to the USB flash drive (see below) Design and Function ...
The USB flash drive can be removed now RT100 Control System - Activating Options The RT100 control system can be equipped with different hardware and software options. The software options must be activated with a file loaded by USB stick.
Page 19
V 01/2016 Reversal of rotation >9A/suction Pump regulation Flushing Flow deviation Set-point ramps Design and Function 13 RT100 Control System...
V 01/2016 Technical Data RT100 Control System General Data RT100 Control System Temperature range -25 - 450 °C Outlet control: PID-controller, with 10 hard-coded PID parameter sets or with a PID set that can be set manually. Separate parameter sets for heating and cooling...
V 01/2016 Inputs RT100 Control System Outlet: Pt 100 External (consumer): Temperature sensor Optionally Pt100 (2- or 3-conductor), J (Fe-CuNi), K (NiCr-Ni), T (Cu- CuNi) or N (NiCrSi-NiSi) (Option), 20mA Inlet: Pt 100 (2- or 3-conductor) External set-point value specifica-...
Operation RT100 Control System Operation using short-travel membrane key switch with pressure point in the membrane keyboard and RCD control knob (Regloplas Control Dial). Operation Simple menu guidance in different languages. Set-point value and param- eterisation protected through programmable codes...
V 01/2016 Parameterisation General The parameterisation of the RT100 Control System is carried out with the Parameter button in the menu Parameters. The corresponding parame- ter is selected and set by turning/pressing the RCD control knob. The parameters are described in the following chapters.
2 steps are required so that the device is switched on once and off thereafter. The steps that are not required are set to inac- tive. The active (On/Off) and inactive steps are visible in the second sub-level 20 Parameterisation RT100 Control System...
(Functions like Step 1) Step 5 (Functions like Step 1) Program 2 (Functions like Program 1) Program 3 (Functions like Program 1) Program 4 (Functions like Program 1) Program 5 (Functions like Program 1) Parameterisation 21 RT100 Control System...
Selection of the set-point ramp heating (Gradient, Filter or Inactive) Set-point ramp cool- Gradient cooling Setting in °C/min Filter time constant cool- Setting in sec. Set-point ramps Evacuation time Parameter Remarks Evacuation time Evacuation time duration (0-500 sec.) 22 Parameterisation RT100 Control System...
Excel. There is also a special import filter for the Famos Reader software for quick overviews of data. Please use a Regloplas USB flash drive for USB logging (part no. 176-100026). Monitoring (Password level - Technician password)
Actual value setting - low pass (in seconds) Low pass offset refer- Offset setting - low pass (in seconds) ence Deviation Deviation setting (-100-0%) Alarm suppression Setting of duration of the alarm suppression (in sec.) Flow monitoring 24 Parameterisation RT100 Control System...
Setting control parameter I Cooling (in sec.) D Cooling Setting control parameter D Cooling (in sec.) Power limit cooling Capacity limitation Cooling (0-100%) Setting of neutral zone cooling (0-10% of set- Neutral zone cooling point value) Parameterisation 25 RT100 Control System...
Input of the minimum actuation time, cooling (in milliseconds) Control system modes The RT100 Control System works with the following control algorithms: PID control on outlet, inlet or external sensor - for this control type, there are 10 fixed parameter sets each available for heating and...
Pressure decrease Integral Input integral (in sec.) Power increase Input power increase (in %) Power limitation at 1 bar Input limitation increase (in %) Power limitation at 7 bar Input limitation increase (in %) Parameterisation 27 RT100 Control System...
Input run-on time of pump after switching off Cooling capacity Input of cooling capacity for cooling process Input evacuation type ("Inactive", "With pump" or "With pressure") Emptying (Software op- Evacuation type tion) with pressure with Y8/with Y18 28 Parameterisation RT100 Control System...
Page 35
Input flushing time ("Off", "With Y19" or "With Flushing Y2/Y8") Start flushing (Active/Inactive) Start flushing time (in sec.) Max. flushing tem- Flushing (in °C) perature Settings Interval flushing (Active/Inactive) Interval time (in min.) Interval flushing (in sec.) time Parameterisation 29 RT100 Control System...
The unit can be switched on and off via the external contact (closing of the external con- Code 3 tact - unit switches on / opening of the exter- nal contact - device switches off) 30 Parameterisation RT100 Control System...
Manual calibration starts when, in the menu, the parameter Manual cali- bration is set to ON. The user is thereupon prompted to close the ball valve in the outlet (flow = 0 l/min). When the ball valve is closed, the pa- Parameterisation 31 RT100 Control System...
Page 38
The existing characteristic curve can be overwritten by a new characteristic curve at any time. In the menu item Save/Load / Load characteristic curve F1000, a characteristic curve can be loaded from the USB stick. 32 Parameterisation RT100 Control System...
Heating 2 on Cooling on Pressure increase Pressure decrease Maintenance Pump regulation Start/Stop Data input output O2 (for functions, see out- put O1) Pump regulation Right/Left Data input: output O3 (for functions, see out- put O1) Parameterisation 33 RT100 Control System...
Relay K1 Service Relay Max heat./cool. time Power ON Common alarm (see the param- eter " Common alarm") Heating 1 Heating 2 Minimum flow rate Alarm Flow monitor Level Pump current Deviation Set-point/Outlet HI 34 Parameterisation RT100 Control System...
Switch over heat carrier - reboot of the machine required RTC Error or empty battery - Time and date settings lost External set-point signal disconnected or not available Direction of rotation cannot be changed Parameterisation 35 RT100 Control System...
Saving the user settings AIC Loading the factory settings Loading the factory settings Save the factory settings Saving the factory settings (Regloplas password required) Load settings from USB stick Loading the settings from the USB stick Save settings to USB stick...
Activate options Wait for USB stick of the control system is required for this pur- pose Display of the base module serial number of the RT100 Control System Serial number (8 letters, e.g. AALARP) 38 Parameterisation RT100 Control System...
V 01/2016 Plug Nomenclature RT100 Front panel Plug Designation Options Base module Interfaces Universal RP or 20 mA CL USB Host USB Device RT100 Base Module Plug Designation Display and operations module (front panel) Base module Options Options Options Power supply...
Page 50
X32:2 Feedback Heating 1 X33:1 Feedback Heating 2 X33:2 Feedback Heating 2 X34:1 Thermostat F7 X34:2 Thermostat F7 X35:1 AC In X35:2 AC In X36:1 AC In X36:2 AC In X37:1 AC In 44 Plug Nomenclature RT100 Control System...
V 01/2016 RT100 Digital Option The digital functions of the RT100 Digital Option are mirrored identically on the RT100 Analog Option. Digital Functions Plug Designation X80:1 External heating X80:2 External cooling X80:3 External heating/cooling active X80:4 External On/Off X80:5 External toggling SP1-SP2...
X101:8 Analog output 2 TC X101:9 GND outputs X101: 1, 3-8 RT100 Option Reversal of Direction of Rotation >9A The RT100 option for reversal of the direction of rotation >9A is intended for motor currents >9 A. Plug Designation X120:1...
V 01/2016 Hardware RT100 Front Panel - Layout RT100 Front Panel Print - Layout CAUTION Electronic parts can be damaged by electrostatic charges. For this reason, proper grounding must be ensured during installation! Fasten an antistatic wristband to your wrist before installing electronic compo- nents! Hardware ...
V 01/2016 Analog Option - Layout The digital functions of the RT100 Analog Option are mirrored identically on the RT100 Digital Option. Analog function Digital function Analog Option - Layout CAUTION If both a digital option and an analog option are installed, the digital functions...
V 01/2016 Digital Option - Layout The digital functions of the RT100 Digital Option are mirrored identically on the RT100 Analog Option. Relay function Digital function Digital Option - Layout CAUTION If both a digital option and an analog option are installed, the digital functions...
V 01/2016 Option Reversal of Direction of Rotation >9A - Layout Option Reversal of Direction of Rotation >9A - Layout Option Current Monitoring Heating - Layout Option Current Monitoring Heating - Layout Hardware 53 RT100 Control System...
V 01/2016 Fault Rectification Alarm Messages The RT100 Control System can display various error messages (warn- ings and alarms). Attention must be paid to these error messages without fail, otherwise, malfunctions of / damage to the temperature control unit and production downtimes may result.
Check pump/pump motor (with ohmmeter) and re- Motor current exceeded place, if necessary Phase sequence failure Correct the phase sequence (interchange 2 phases) Phase sequence unidentified Switch off phase sequence monitoring 58 Fault Rectification RT100 Control System...
Clean the external filter External set-point signal disconnected or not available Connect the external set-point signal RTC Error or empty battery - Time and date settings Set the correct date/time and/or replace the battery on Fault Rectification 59 RT100 Control System...
Page 66
Option missing or faulty: Analog Option, Digital Option, Heating current monitor- Connect the corresponding option or switch off in the ing, Reversal of direction of rotation, Profibus, Profinet, parameter Hardware Options Ethernet/IP, CAN Demag, CANopen 60 Fault Rectification RT100 Control System...
Fasten the front panel with 6 screws on the device door Reconnect all plug-in connectors Loading the firmware See the section "RT100 Control System - Loading the firmware". RT100 Control System - Maintenance/repair 61 RT100 Control System...
Is the motor fuse F10 (10 A aM/Class CC) fitted? Is the relay plug K1 connected? Loading the firmware See the section "RT100 Control System - Loading the firmware". Activating options See the section "RT100 Control System - Activating options". 62 RT100 Control System - Maintenance/repair...
V 01/2016 Loading the factory settings The factory settings are restored in the Save/Load parameter in the Load factory settings menu. This returns the RT100 to the manufactur- er's default settings. Configuration check The unit configuration must be checked to determine whether everything has functioned correctly.
In the case of dual units, address 1 is set for zone 2 (rotary switch S2). Connection com- Description bination Front panel with one base module Both terminating resistors are switched on (checked by Regloplas) Front panel with two base modules One option Several options 64 RT100 Control System - Maintenance/repair...
Page 71
V 01/2016 Connection com- Description bination Front panel with option Front panel with option RT100 Control System - Maintenance/repair 65 RT100 Control System...
(also see the service section) and in the electrical circuit diagram of the device. CAUTION Only original Regloplas spare parts may be used! In case of damage from the use of non-original parts, the warranty will be ren- dered null and void! Spare Parts ...