MLB1006 Serisi 3.1.3. Maximum capacity setting: ........................- 13 - 3.1.4. Zero point calibration: ..........................- 13 - 3.1.5. Second point calibration: (Unit is in kg/ lb) ..................- 13 - 3.2. Fast calibration mode: ............................- 13 - APPENDIX: Word Table ..............................- 14 - YETKİLİ...
MLB1006 Serisi TÜRKÇE Genel Uyarılar, Montaj Uyarıları Kullanılmadığında, baskülü serin ve kuru bir ortamda saklayın. Özellikle aşırı sıcakta bırakmayın. Cihaz deterjanlı suyla nemlendirilmiş bir bezle silinerek temizlenmelidir. Benzin, gaz, tiner gibi sıvılar ve sert temizleme maddeleri kesinlikle kullanılmamalıdır. İyice kuruduktan sonra şebeke bağlantısı...
MLB1006 Serisi Opsiyonlar: n RS-232 veya yazıcı Özellik tablosu: Minimum 350 ohm load cell Maximum 1000 ohm Load Cells (En fazla 4 load cell, 350 ohm) Çözünürlük Seçilebilir, 0,0 Dara Maksimum çekere kadar Ölçüm Kg , lb Birimleri Şarj edilebilir akü veya şarj cihazı DC 7.2V 1A Güç...
MLB1006 Serisi 1.4 Baskülün çalıştırılması 1.4.1 Sayıcı Modu 1. “F” tuşuna bir kez basılır, gösterge : Örnek miktarını seçmek için (10, 20, 50,100) “>0<” tuşuna basılır, baskülün üzerine örnek miktarı kadar ürün yerleştirilir, “P” tuşuna basılarak sayıcı modunda çalışmaya başlanır.
MLB1006 Serisi 1.5 Güç Kaynağı 1. 6V 4Ah akü, 2. 220V AC/DC adaptör Güç Harcaması 1. Yaklaşık DC 17mA (gösterge aydınlatması olmadan) 2. Yaklaşık DC 37mA (gösterge aydınlatması ile beraber) Bölüm II Gelişmiş Fonksiyonlar 2.1 Akü Seviyesi kontrolü Baskül açık durumda ve üzerinde ağırlık yokken (Denge konumunda olmalı) “>0<” tuşuna uzun basılır, sesli ikaz gelince tuş...
MLB1006 Serisi ENGLISH Before using the scale Thank you for purchasing High Precision Electronic Weighing Scale. In order to use the scale properly, please read this User Manual carefully before use. If you have any problem with scale, please contact your supplier.
MLB1006 Serisi Chapter I Introduction 1.1 Features and specification Features: n Large display (digit height 30mm x 13mm) with backlight n Kilogram (kg), and pound (lb) weighing modes n Application include: simple counting , hold, accumulation n Low power indication and auto power off...
MLB1006 Serisi 1.2 Display PRINT FUNC UNIT TARE ZERO 1. Zero status indication, Displayed when the scale is at the centre of its zero band. 2. Tare status indication, Displayed when the weight has been tare. 3. Simple counting indication, Displayed when the scale is in simple counting mode.
MLB1006 Serisi FUNCTION KEY: FUNCTION This key is Use this key to choose the functions: Simple counting, Check weighing, Accumulation PRINT KEY: PRINT This key is key; in the menu use as “CONFIRM“ key Use this key to print data when the printer is connected.
MLB1006 Serisi objects are put on pan and the scale is stable. 2. Take off the object and press ZERO key the until back to zero . Press FUNCTION key to exit HOLD mode and move back to weighing mode.
MLB1006 Serisi 2.2 Auto back light setup (This function LCD effective) When scale is on and at zero and stable, long press TARE key enter the auto back light setup, use ZERO key to enable or disable, then press PRINT key to confirm and back to weighing mode.
MLB1006 Serisi Ex. When display shows [p 0.000], Press “PRINT” key, the division set as 0.000, then enter the maximum capacity setting. 3.1.3. Maximum capacity setting: Display shows [ FULL ] around 2-3 seconds then display shows [000.000] the decimal point was set as 3 decimal points, then press “TARE”...