  • Page 1 Real Fires Outdoor Installation Instructions realfi res.co.nz...
  • Page 2: Typical Installation

    Unfl ued Model Installation Instructions The Real Fires SS900 unfl ued outdoor Gas Fire is suitable for installation into masonry only. This model removes the need for a fl ue system, however there are important considerations to be made prior to installation.
  • Page 3 40 MJ/Hr Electrical There are no electrical options on the Real Fires outdoor fi re. Installation of rebox Position the fi rebox in front of the masonry cavity. Straighten out the 10mm copper gas pipe from its coil at the back of the masonry cavity and feed it through the hole in the back of the fi...
  • Page 4 The stainless steel front cover is designed to be in place to protect the fi re from the weather when the fi re is not in use. Instruct User Once the installation is complete, instruct the user on the operation of the fi re and complete commissioning details in the Real Fires user manual. ALL INSTALLATIONS MUST BE CERTIFIED realfi res.co.nz...
  • Page 5 realfi res.co.nz...
  • Page 6 Real Fires Log and Coal Layout This drawing is a typical example of the log and coal layout on a Real Fire 800. The layout is basically the same for Real Fires Log and Coal Layout all models with logs and coals decreased or increased in width to suit the size of fi re. (The pilot ignition assembly has been omitted from the drawing).
  • Page 7 Unfl ued Model Non-Combustible Cavity The Real Fires SS900 unfl ued outdoor Gas Fire is suitable for installation into a timber framed construction lined with a non-combustible material. This model does not need a fl ue system; however there are important considerations to be made prior to installation.
  • Page 8 40 MJ/Hr Electrical There are no electrical options on the Real Fires outdoor fi re. Installation of rebox Position the fi rebox in front of the masonry cavity. Straighten out the 10mm copper gas pipe from its coil at the back of the masonry cavity and feed it through the hole in the back of the fi...
  • Page 9 Once the installation is complete, instruct the user on the operation of the fi re and complete commissioning details in the Real Fires user manual. ALL INSTALLATIONS MUST BE INSTALLED TO CURRENT LOCAL AND REGULATORY STANDARDS AND BY LAWS AND INSTALLATION MUST BE CARRIED OUT BY A QUALIFIED PERSON.
  • Page 10 Real Fires Log and Coal Layout This drawing is a typical example of the log and coal layout on a Real Fire 800. The layout is basically the same for all models with logs and coals decreased or increased in width to suit the size of fi re. (The pilot ignition assembly Real Fires Log and Coal Layout has been omitted from the drawing).
  • Page 11 SS900 Outdoor Gas Fire Flued Model The Real Fires SS900 Flued outdoor fi re is suitable for installation into masonry only. This model is not suited to tim- ber framed installations. Location The Real Fires SS900 Flued gas fi re is designed to be installed in sheltered outdoor situations. Exposed locations are not suitable.
  • Page 12: Flue Requirements

    As the Real Fires SS900 outdoor fi re is for installation into masonry only, twin wall fl ue is not required. Flue bends are available from Real Fires if the fl ue needs to be o set as shown in installation drawing.
  • Page 13 Installation of Real Fires burner into rebox The burner is supplied boxed complete with grate, ash cover, vermiculite, logs and coals. To make the gas connec- tion, place the burner into the fi rebox so that the back of the burner is touching the back of the fi rebox and is po- sitioned central.
  • Page 14 The stainless steel front cover is designed to be in place to protect the fi re from the weather when the fi re is not in use. Instruct User Once the installation is complete, instruct the user on the operation of the fi re and complete commissioning details in the Real Fires user manual. ALL INSTALLATIONS MUST BE CERTIFIED realfi res.co.nz...
  • Page 15 realfi res.co.nz...
  • Page 16 realfi res.co.nz...
  • Page 17 Real Fires Log and Coal Layout This drawing is a typical example of the log and coal layout on a Real Fire 800. The layout is basically the same for Real Fires Log and Coal Layout all models with logs and coals decreased or increased in width to suit the size of fi re. (The pilot ignition assembly has been omitted from the drawing).