Emerson MD1777 Service Manual page 2

In car dvd-video player
Table of Contents

Advertisement

• Safety Check after Servicing
Examine the area surrounding the repaired location for damage or deterioration. Observe that screws, parts and wires
have been returned to original positions. Afterwards, perform the following tests and confirm the specified values in
order to verify compliance with safety standards.
1. Insulation resistance test
Confirm the specified insulation resistance or greater between power cord plug prongs and externally exposed parts
of the set (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, earphone
jacks, etc.). See table below.
2. Dielectric strength test
Confirm specified dielectric strength or greater between power cord plug prongs and exposed accessible parts of the
set (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, earphone jacks,
etc.) See table below.
3. Clearance distance
When replacing primary circuit components, confirm
specified clearance distance (d), (d') between soldered
terminals, and between terminals and surrounding
metalic parts. See table below.
Table 1: Rating for selected areas
AC Line Voltage
100V
110 to 130V
* 110 to 130 V
200 to 240 V
* Class II model only.
Note: This table is unofficial and for reference only. Be sure to confirm the precise values for your particular country
and locality.
4. Leakage current test
Confirm specified or lower leakage current between B (earth ground, power cord plug prongs) and externally
exposed accessible parts (RF terminals, antenna terminals, video and audio input and output terminals, microphone
jacks, earphone jacks, etc.)
Measuring Method: (Power ON)
Insert load Z between B (earth ground, power cord plug
prongs) and exposed accessible parts. Use and AC
voltmeter to measure across both terminals of load Z.
See figure and following table.
Table 2: Leakage current ratings for selected areas
AC Line Voltage
100V
110 to 130 V
110 to 130 V
200 to 240 V
Note: This table unofficial and for reference only. Be sure to confirm the precise values for your particular country and
locality.
Insulation
Region
Resistance
≥ 1 MΩ/500 V DC
Japan
USA &
Canada
Europe
≥ 10 MΩ/500 V DC
Australia
Region
Japan
1.5kµF
USA &
Canada
Europe
Australia
Chassis
Dielectric
Strength
1kV 1 minute
– – –
900V 1 minute
4 kV 1 minute
Exposed
accessible
part
Load Z
Leakage Current (i)
¡ ≤ 1m A rms
1k
¡ ≤ 0.5 m A rms
1.5k
¡ ≤ 0.7 m A peak
¡ ≤ 2 m A dc
2k
¡ ≤ 0.7 m A peak
¡ ≤ 2 m A dc
50k
d
Primary circuit terminals
d'
a
Fig. 1
Clearance
Distance (d), (d')
≥ 3 mm
≥ 3.2mm
≥ 6 mm (d)
≥ 8 mm (d')
(a: Power cord)
AC Voltmeter
Z
(high impedance)
Earth Ground
B
power cord plug prongs
Fig. 2
Earth Ground
(B) to:
Exposed accessible
parts
Exposed accessible
parts
Antenna earth
terminals
Other terminals

Advertisement

Table of Contents
loading

Table of Contents