Dolphin TCM 330 User Manual

Wireless led controller module
Table of Contents

Advertisement

Quick Links

USER MANUAL V1.1
TCM 330 / TCM 330U
Wireless LED Controller Module
TCM 330 / TCM 330U
11.08.2016
Observe precautions! Electrostatic sensitive devices!
Patent protected:
WO98/36395, DE 100 25 561, DE 101 50 128,
WO 2004/051591, DE 103 01 678 A1, DE 10309334,
WO 04/109236, WO 05/096482, WO 02/095707,
US 6,747,573, US 7,019,241
© 2016 EnOcean | www.enocean.com
F-710-017, V1.2
TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 1/62

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TCM 330 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dolphin TCM 330

  • Page 1 WO 2004/051591, DE 103 01 678 A1, DE 10309334, WO 04/109236, WO 05/096482, WO 02/095707, US 6,747,573, US 7,019,241 © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 1/62...
  • Page 2 Components of the modules are considered and should be disposed of as hazardous waste. Local government regulations are to be observed. Packing: Please use the recycling operators known to you. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 2/62...
  • Page 3: Table Of Contents

    Occupancy sensor in stand-alone mode ..........31 4.5.2.2 Occupancy sensor and switches ............32 4.6 Wireless light level sensors ................33 © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 3/62...
  • Page 4 FCC Regulatory Statements ..............60 IC (Industry Canada) Certification ..............61 7.2.1 Industry Canada Regulatory Statements ..........62 © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 4/62...
  • Page 5: Module Variants And Related Documents

    TCM 330: 868.300 MHz TCM 330U: 902.875 MHz Within this user manual the term TCM 330 is used to describe both TCM 330 and TCM 330U unless otherwise noted. For system development we recommend following our application notes, in particular: AN101: Power Supply Layout –...
  • Page 6: General Description

    Such controllers use wireless technology to communicate with other self-powered EnOcean based products to provide simple yet powerful solutions for dimming control of LED lighting. TCM 330 can control the dim level of connected LED light sources based on input from the following devices: Up to 20 switches...
  • Page 7: Technical Data Tcm 330 / Tcm 330U

    1) according to ISO/IEC 14543-3-10 2) according to ISO/IEC 14543-3-11 3) @ 0.1% telegram error rate (based on 3 transmitted sub-telegrams) © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 7/62...
  • Page 8: Physical Dimensions

    0% … 93% r.H., non-condensing Ordering information Type Ordering Code Frequency TCM 330 S3003-K330 868.300 MHz TCM 330U S3053-K330 902.875 MHz © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 8/62...
  • Page 9: Hardware Design Description

    HARDWARE DESIGN DESCRIPTION Pin out The figure above shows the pin out of the TCM 330 LED Controller module. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 9/62...
  • Page 10: Pin Description

    Programming I/F Dual use (also GREEN LED) (see 3.5.8) WSDADIO2 21 Dual use (also RED LED) SCLKDIO1 SCSEDIO0 ADIO7 © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 10/62...
  • Page 11: Absolute Maximum Ratings (Non-Operating)

    Voltage at WXIDIO / WXODIO input pin VIND2 (LRN / DIM button) VDDR Max. ripple at VDD mVpp © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 11/62...
  • Page 12: System Design

    In addition, an HF SMD EMI Suppression Ferrite Bead such as the Würth WE-CBF HF SMD EMI Suppression Ferrite Bead (Würth order number 742863160) can be inserted into the power supply line. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 12/62...
  • Page 13: 0-10V Output Driver

    The gain of the amplifier must be chosen according to the IO voltage of TCM 330 such that 100 % duty cycle at the TCM 330 PWM output will result in 10V output voltage at the driv- The output of the 0-10V driver should be properly ESD protected if it is exposed to user contact.
  • Page 14: Relay Output

    LED driver connected to the output of the LED controller. TCM 330 provides two outputs for relay control: Primary Relay Control This output signal is set to active (high) if the output of TCM 330 is ON (output level > 0V); otherwise it is inactive (low). Relay Overdrive This output signal is set to active (high) for a period of 110 ms during the transition from relay OFF to ON state.
  • Page 15: Zero Cross Detection

    AC line frequency (60 Hz or 50 Hz) and calculates the timing of subsequent zero crossings based on that. TCM 330 allows specifying timing offsets both for relay close and relay open actions to ac- count for the timing difference between relay control signal change and relay contact state...
  • Page 16: Eeprom

    The recommended EEPROM is Microchip 24AA08. An I2C interface to the EEPROM is implemented in TCM 330 providing SCL and SDA inter- face signals. External 1k pull up resistors to VDD (positive supply voltage) are required for correct operation.
  • Page 17: Antenna

    Note that a full FCC / IC approval is needed if TCM 330U modules are used in US / Canada with antennas other than these specified antennas. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 17/62...
  • Page 18: Whip Antenna

    Design according to drawing below. Minimum GND plane: 35 mm x 30 mm Minimum distance space: 10 mm © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 18/62...
  • Page 19: Chip Antenna (Mitsubishi Material, Type Am11Dg-St01)

    For additional information or chip antenna quotes, please refer to Mitsubishi Materials web- site at www.mmea.com or email to electroniccomponents@mmus.com. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 19/62...
  • Page 20: Local Interface

    3.5.7 Local interface TCM 330 provides the option to use a local interface for simple configuration and status display tasks. This interface consists of two pushbuttons (called LRN and DIM) and two LED (red and green, either as two separate LED or as an integrated bi-color solution).
  • Page 21: Programming And Configuration Interface

    EnOcean can provide a spring-loaded header cable based on 2mm contact spacing for pro- gramming. Please contact EnOcean for details. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 21/62...
  • Page 22: Reset And Programming Input Protection

    The suggested circuit is shown below for the RESET input. The same circuit is should be used for the PROG_EN input. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 22/62...
  • Page 23: Functional Information

    Central control is possible by linking the LED zone controller to a central controller or via a gateway to building automation systems like BACnet. LED zone controller based on TCM 330 can be wirelessly configured over the air using the EnOcean Remote Commissioning standard. Configurable parameters are marked in Italics in the following chapters.
  • Page 24: Led Zone Controller

    Wireless LED Controller Module LED zone controller LED zone controller based on TCM 330 acts as the central receiver and processor of input data (commands or status messages) from linked components. Based on this input data, it determines the appropriate lighting level and sets the output signals connected to the LED Driver accordingly.
  • Page 25: Pwm Output Functionality

    4.3.2 Status message functionality LED zone controller based on TCM 330 can report their current status at random intervals to a central controller or gateway. This functionality can be used both to enable system status control and to provide status visualization via a user interface.
  • Page 26: Repeater Functionality

    TCM 330 is linked to. This Link-based Repeating option is enabled by default and should be disabled only if required. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 26/62...
  • Page 27: Wireless Switches

    Additional product information for these energy harvesting switches can be found here: https://www.enocean.com/en/enocean_modules_902mhz/wireless-switch-esrp-edrp-oem/ LED zone controller based on TCM 330 can accept input from up to 20 wireless switches using EnOcean End Equipment Profile (EEP) F6-02-02. © 2016 EnOcean | www.enocean.com F-710-017, V1.2...
  • Page 28: Functional Behaviour Of Wireless Switches

    This feature is automatically disabled if an occupancy sensor is present. In this case, au- tomatic switch OFF of the light will be performed based on the input from the occupancy sensor. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 28/62...
  • Page 29: Wireless Occupancy Sensors

    330 can be found here: https://www.enocean.com/en/enocean_modules/wall-mounted-occupancy-sensor-eosw- oem/ https://www.enocean.com/en/enocean_modules/ceiling-mounted-occupancy-sensor-eosc- oem/ Likewise information for TCM 330U can be found here: https://www.enocean.com/en/enocean_modules_902mhz/wall-mounted-occupancy- sensor-eosw-oem/ https://www.enocean.com/en/enocean_modules_902mhz/ceiling-mounted-occupancy- sensor-eosc-oem/ © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 29/62...
  • Page 30: Functional Behaviour Of Wireless Occupancy Sensors

    No dedicated “unoccupied” telegram has to be sent. EnOcean TCM 330 based LED controllers can receive input from up to 10 wireless occupan- cy sensors using EnOcean Equipment Profiles (EEP) A5-07-01, A5-07-02 or A5-07-03.
  • Page 31: Functionality Depending On System Configuration

    Setting OccAutoOffTimer to 0 (which disables Auto OFF functionality) should be avoided if only occupancy sensors are linked. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 31/62...
  • Page 32: Occupancy Sensor And Switches

    OFF function of the occupancy sensor will set the light to that level. Light can then be switched fully OFF by single or double click on the “0” button of a linked wireless switch. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 32/62...
  • Page 33: Wireless Light Level Sensors

    TCM 330U. Detailed information about this ceiling-mounted energy harvesting wireless light level sen- sor can be found here: https://www.enocean.com/en/enocean_modules_902mhz/light-level-sensor-ells-oem/ © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 33/62...
  • Page 34: Functional Behaviour Of Wireless Light Level Sensors

    The default operation mode is five point dimming. Two level dimming can be enabled by setting DaylightingMode accordingly. Both modes are described in more detail now. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 34/62...
  • Page 35: Five Point Dimming

    4 and 5 then the ramp speed RAMP45 is used irrespective of the current light level. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 35/62...
  • Page 36: Dimming Curve Adjustment

    Doing so for different illuminations allows redefining the whole curve. This feature can be disabled by setting LlsEnableCurveAdjustment to OFF. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 36/62...
  • Page 37: Two Level Dimming

    The default value of PhotoOnThres 200 lux is while the default value of PhotoOffThres is 400 lux. The resulting default dimming curve is shown below. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 37/62...
  • Page 38: Functionality Depending On System Configuration

    Both two level (ON / OFF) and five point (continuous) dimming can be used in this configu- ration. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 38/62...
  • Page 39: Light Level Sensor And Switches

    0% (OFF) level due to input from the Light Level Sensor. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 39/62...
  • Page 40: Light Level Sensor And Occupancy Sensors

    OccAutoOffTimer) then light will remain at OccAutoOffLevel irrespective of light level sensor input. Note that OccAutoOffLevel does not have to be 0% (OFF). © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 40/62...
  • Page 41: Light Level Sensor With Occupancy Sensors And Wireless Switches

    Likewise, if light has been switched OFF by a linked wireless switch then it will remain in OFF state irrespective of light level sensor input. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 41/62...
  • Page 42: Central Controllers

    LED zone controllers can be connected to a demand response controller based on EnOcean Equipment Profile (EEP) A5-37-01. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 42/62...
  • Page 43: System Configuration

    PIN code and this PIN code is lost. In order to reset TCM 330 to factory state, press and hold the LRN button for 10 seconds. After that the red LED output will be set to active for 10 seconds.
  • Page 44: Setting The Minimum Output Voltage

    Transceivers (Gateways or controllers) can exchange data and commands with TCM 330 These two component types are described in more detail now. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 44/62...
  • Page 45: Linking To Transmitters (Transmit-Only)

    Transmitters can only be linked to transceivers, not to other transmitters. To link TCM 330 with a transmitter, the LED controller must be powered and within wireless range of the transmitter it is to be linked to. Please follow these steps to link a transmitter with TCM 330 using the local control interface: 1.
  • Page 46: Linking To Transceivers (Transmit & Receive)

    (switching a light ON or OFF for example). LED zone controller based on TCM 330 can be linked to other transceivers if desired. The following other transceiver types are supported: Central Controller...
  • Page 47: Factory-Configurable Parameters

    Active only on OFF to ON transition Please contact EnOcean for support if modification of these parameters is required. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 47/62...
  • Page 48: Remote Commissioning

    Navigan™ Wireless Commissioner Navigan™ Wireless Commissioner enables setting all configuration parameters of LED con- trollers based TCM 330 wirelessly over the air. This provides a quick and convenient way of configuring LED controller systems without requiring physical access to the device.
  • Page 49: Configurable Parameters

    Enables or disables user adjustment of the 5 point dimming curve LlsEnableCurveAdjustment ON (enabled) using triple click on the “I” button © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 49/62...
  • Page 50 (If a learn telegram from a linked device is received while in operating ON (enabled) mode, the 0-10V output will toggle once between 10% and 90%) © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 50/62...
  • Page 51: Application Information

    (1.5 ft). An application note to determine the transmission range within buildings is available as download from www.enocean.com. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 51/62...
  • Page 52: Recommendations For Laying A Whip Antenna

    GND area ü Antenna end led back to foot point Antenna too close to GND area ü © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 52/62...
  • Page 53: Layout Recommendations

    If such signals are present in your design, we suggest separating them by using a ground plane between module and these signal lines. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 53/62...
  • Page 54: Recommended Foot Pattern

    TCM 330 / TCM 330U Wireless LED Controller Module 6.3.1 Recommended foot pattern Top layer Solder resist top layer © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 54/62...
  • Page 55 An application and production specific test regarding the amount of soldering paste should always be performed to find optimum parameters. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 55/62...
  • Page 56: Soldering Information

    TCM 330 has to be soldered according to IPC/JEDEC J-STD-020C standard. TCM 330 shall be handled according to Moisture Sensitivity Level MSL4 which means a floor time of 72 h. TCM 330 may be soldered only once, since one time is already consumed at production of the module itself.
  • Page 57: Tape & Reel Specification Tcm 330

    TCM 330 / TCM 330U Wireless LED Controller Module 6.3.3 Tape & Reel specification TCM 330 Tape running direction © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 57/62...
  • Page 58: Regulatory Information

    © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 58/62...
  • Page 59 The user manual for the end product must also contain the text given above. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 59/62...
  • Page 60: Fcc Regulatory Statements

    Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/ TV technician for help © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 60/62...
  • Page 61: Ic (Industry Canada) Certification

    L'OEM doit signer l'accord OEM limitée Approbation modulaire avec EnOcean Please contact EnOcean if you intend to use EnOcean’s IC ID number. © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 61/62...
  • Page 62: Industry Canada Regulatory Statements

    This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada © 2016 EnOcean | www.enocean.com F-710-017, V1.2 TCM 330 / TCM 330U User Manual | v1.1 | August 2016 | Page 62/62...

This manual is also suitable for:

Tcm 330u

Table of Contents