    Dear Customer: Thank you for purchasing our generator. We want to help you get the best results from your new generator and to operate it safely. This manual contains the information on how to do that; please read it carefully before operating or performing any adjustments on your generator.
  • Page 3: Safety Label Location

    SAFETY SAFETY LABEL LOCATION These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your dealer for a replaceme nt them.
  • Page 4: Safety Precaution

    SAFETY PRECAUTION Our generators are designed to give safe and dependable service if operated according to instructions. Please read and understand this owner's manual before operating your generator. You can help prevent accidents by being familiar with your generator's controls, and by observing safe operating procedures.
  • Page 5 Fire and Burn Hazards 1.The exhaust system gets hot enough to ignite some materials. -Keep the generator at least 1 meter (3 feet) away from buildings and other equipment during operation. -Do not enclose the generator in any structure. -Keep flammable materials away from the generator. 2.The muffler and muffler cover becomes very hot during operation and remain hot for a while after stopping the engine.
  • Page 6: Name Of Parts

    NAME OF PARTS...
  • Page 7 CHOKE LEVER SPARK PLUG CAP (INSIDE THIS COVER)
  • Page 8 HOW TO HANDLE PARTS Engine Switch Switch position OFF: To stop the engine. ON : To run the engine. Recoil Starter To start the engine, pull the starter grip lightly until resistance is felt, then pull briskly. Do not allow the starter to snap back against the engine. Return it gently to prevent damage to the starter.
  • Page 9: Circuit Breaker

    Circuit Breaker The Circuit breaker will automatically cut off the circuit if there is a short circuit or a significant overload of the generator at the receptacle. If the circuit breaker is OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before push to reset the circuit breaker.
  • Page 10: Connections To A Building's Electrical System

    HOW TO HANDLE GENERATOR Connections to a Building's Electrical System Connections for standby power to a building's electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes. Improper connections to a building's electrical system can allow electrical current from the generator to backfeed into the utility lines.
  • Page 11: Battery Charge

    AC Operation ①Start the engine. ②Plug in the appliance. Do not exceed the current limit specified for any one receptacle. If an overloaded circuit for a long time causes the receptacle to burn. Most motorized appliances require more than their rated wattage for startup. If overloaded of the generator the circuit breaker is off, reduce the electrical load on the circuit and then push to reset circuit breaker.
  • Page 12: Pre-Operation Check

    PRE-OPERATION CHECK Engine oil Engine oil is a major factor affecting engine performance and service life. Non-detergent and 2-stroke engine oils will damage the engine and are not recommended. Check the oil level BEFORE EACH USE with the generator on a level surface with the engine stopped.
  • Page 13: Fuel Recommendation

    Fuel Recommendation ①Remove the fuel cap. ②Check the fuel level. ③Refill the tank if the fuel level is low. Do not fill above the shoulder of the fuel strainer. 1.Gasoline is extremely flammable and is explosive under certain conditions. 2.Refuel in a well-ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored.
  • Page 14: Oxygenated Fuels

    Oxygenated Fuels Some gasolines are being blended with alcohol or an ether compound to increase the octane. These gasolines are collectively referred to as oxygenated fuels. Some areas use oxygenated fuels to help meet clean air standards. If you use an oxygenated fuel, be sure its pump octane rating is 86 or higher. Ethanol (ethyl or grain alcohol) Gasoline containing more than 10% ethanol by volume may cause starting and/or performance problems.
  • Page 15: Starting The Engine/Stopping The Engine

    STARTING THE ENGINE/STOPPING THE ENGINE Starting the engine ①Turn the fuel valve to the "OPEN" position. ②Turn the choke lever to the "CLOSE" position. ③Move the engine switch to the "ON" position. ④Pull the starter grip until compression is felt, then pull briskly.
  • Page 16: Stopping The Engine

    Stopping the Engine In an emergency: To stop the engine in an emergency, move the engine switch to the "OFF" position. In normal use: ①Move the engine switch to the "OFF" position. ②Turn the fuel valve to the "CLOSE" position.
  • Page 17: Maintenance

    MAINTENANCE Periodic maintenance and adjustment is necessary to keep the generator in good operating condition. Perform the service and inspection at the intervals shown in the Maintenance schedule below. Exhaust gas contains poisonous carbon monoxide. Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated.
  • Page 18: Engine Oil Change

    Engine oil change Drain the oil while the engine is warm to assure complete and rapid draining. ①Remove the drain plug and sealing washer, oil filler cap, and drain the oil. ②Install the drain plug and sealing washer. Tighten the plug securely. ③Refill with the recommended oil and check the level.
  • Page 19: Air Cleaner Service

    Air cleaner service A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas. Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion.
  • Page 20: Spark Plug Service

    Spark Plug Service Recommended spark plugs: BPR6HS (NGK) To ensure proper engine operation, the spark plug must be properly gapped and free of deposit. If the engine has been running, the muffler will be very hot. Be careful not to touch the muffler.
  • Page 21 ⑥Check that the spark plug washer is in good condition, and thread the spark plug in by hand to prevent cross threading. ⑦After the spark plug in seated, tighten with a spark plug wrench to compress the washer. If installing a new spark plug, tighten 1/2 turn after the spark plug seats to compress the washer.
  • Page 22 TRANSPORTING/STORAGE When transporting the generator, turn the engine switch "OFF" and the fuel valve "CLOSE". Keep the generator level to prevent fuel spillage. Fuel vapor or spilled fuel may ignite. Contact with a hot engine or exhaust system can cause serious burns or fires.
  • Page 23 3.Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container. Gasoline is extremely flammable and is explosive under certain conditions. Perform this task in a well ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area during this procedure. 4.Change the engine oil.
  • Page 24: Troubleshooting

    TROUBLE SHOOTING When the engine will not start: Is there fuel in the Refill the fuel tank. tank? Is there enough oil in Add the recommended the engine? oil. Is there a spark from Replace the Take the generator to the spark plug? spark plug.
  • Page 25 No electricity at the AC receptacles: Is the AC circuit breaker, Push to reset the AC circuit “ON”? breaker is “ON”. Check the electrical No Defects Take the generator to an appliance or equipment authorized your dealer. for any defects. Defects ・Replace the electrical appliance or equipment.
  • Page 26: Wiring Diagram

    WIRING DIAGRAM...
  • Page 27: Specifications

    SPECIFICATIONS Model SGE1000M Generator AC Frequency 50Hz 60Hz AC Output Voltage 110,120,220,240V Maximum AC Output 850VA 1000VA Rated AC Output 750VA 900VA DC Output 12V-8.3A Voltage Regulator Condenser Type Engine Model GT240 Air-Cooled,4Cycle,OHV Type Gasoline Engine Displacement 80cm Maximum Power Output 1.8kW (2.4HP)/ 4000min...