  • Page 2: Product Description

    1- PRODUCT DESCRIPTION 1A - GENERAL DESCRIPTION Programming buttons Dip-switch function setting Signaling led (Paragraph 4A-5) (Paragraph 9) Setting trimmers (Paragraph 4b-8) Removable spare fuse 2A accessories fuse “RX Star” radio code receiver 433.920MHz “MEMO” (Paragraph 13B) Extractable memory (Paragraph 13A) External Power connection...
  • Page 3: Main Features

    - Customizable and differentiable slow down in opening and closing thanks to the professional learning procedure (see paragra- ph 6D). - The control unit “Star MM 224” has got a “backjump” (an impulse to the motor at the end of opening and closing, in order to loosen the mechanism, and make the manual release easier.
  • Page 4: Electric Connections

    2 - ELECTRIC CONNECTIONS 2A - CABLES SECTION - The control unit must be powered (by its external fuse box terminal), through a cable which must be at least 3x1.5 mm² wide. If the distance between the control unit and the grounding system is more than 30m it is necessary to install an electric discharger near to the control unit.
  • Page 5 PHOTOCELL CONNECTION - “VIKY 30” VERSION CLOSING PHOTOCELL OPENING PHOTOCELL CONNECTION CONNECTION PHOTOCELL CONNECTION - “VIKY 11” VERSION CLOSING PHOTOCELL OPENING PHOTOCELL CONNECTION CONNECTION 18 16 18 17 3A - START CHANNEL PROGRAMMING PROCEDURE Power the control Press button RADIO Make a transmission unit and set for 2 seconds.
  • Page 6: Control Unit Settings

    4 - CONTROL UNIT SETTINGS 4A - DIP-SWITCHES SETTINGS A change of the DIP 1 “MODE” needs the repetition of the programming procedure. DESCRIPTION DIP STATUS FUNCTIONING Standard backjump MODE Short backjump STEP Opening / Stop / Closing / Stop modality (step by step) Opening / Pause / Closing (it accepts only opening commands) Yes automatic reclosing (set by “PAU”...
  • Page 7 5 - DIP-SWITCHES DESCRIPTION 5A - DIP-SWITCH 1 - MODE If the dip-switch "MODE" is set to ON, the control unit manages the gate's back jump (standard) near mechanical stops. On the contrary, if the dip-switch "MODE" is set to OFF, the control unit generates a smaller back jump compared to the standard one.
  • Page 8 6 - TRAVEL PROGRAMMING PROCEDURE It is necessary to perform the learning procedure to program the travel (see paragraph 6B for the standard proce- dure, or paragraph 6D for the professional procedure). There is also a learning procedure for the pedestrian opening (see paragraph 6E;...
  • Page 9 6D - PROFESSIONAL LEARNING PROCEDURE The installer can set the beginning point of the slowdown through this procedure. The beginning point is customizable in opening and closing. On steps 9a and 12a of the programming procedure, the first wing is the one which opens as first and closes as second (connected to terminals 24, 25 “MOT1”).
  • Page 10 7 - PARTIAL OPENING LEARNING PROCEDURE The pedestrian opening is a partial opening (or total opening, if the installer wants it) of the wing opened by “MOT1” (terminals 24, 25). To manage the pedestrian opening, it is necessary to program a button of the radio transmitter (see paragraph 3B), or connect a command by wire on the terminals 14,15 (see paragraph 10B).
  • Page 11: Warning Led

    8 - TRIMMER 8A - Trimmer “FOR” – Power / speed of the motor Use the “FOR” trimmer to adjust the voltage with which the motor is powered during operation, thus adjusting its speed. A variation of the “FOR” trimmer requires the repetition of the learning procedure since the operation times, and thus the moments in which to start the slow-down, vary.
  • Page 12 10 - CABLE COMMANDS CONNECTABLE 10A - STARTING COMMAND CONNECTION In the “START” input (terminals 12, 13) it is possible to connect a normally open contact (for example, key selectors, or switches) to manage the automation. The commands can be set by dip switches 2, 3 and 7 (see paragraph 4A, 5). There are 2 micro switches in the selectors;...
  • Page 13: Operation Of The Safety Devices

    11 - OPERATION OF THE SAFETY DEVICES 11A - CLOSING SAFETY DEVICES It is possible to connect normally closed contact devices to the “PHO1” input (terminal 16,18). These devices operate during the closing cycle. In particular: - in closing phase, an immediate inversion of the motion. - in opening phase, they have no effect.
  • Page 14 12 - OTHER CONNECTABLE ACCESSORIES 12A - FLASHING LAMP It is possible to connect flashing light devices to the “LAMP” input (terminals 8,9). These devices turn on a second before the manoeuvre. If the dip 5 “LAMP” is ON position, the power supplied is intermittent. Therefore, a normal lamp can be connected. If the dip 5 “LAMP”...
  • Page 15 14 - INCONVENIENTS AND REMEDIES 14A - THE AUTOMATION DOESN’T START - Check the presence of voltage in the terminals of the external fuse box. - Check the fuse (see paragraph 1A). - STOP contact open (red led “ST” is off): check for possible STOP commands connected (terminal 14). If absent, connect the input with terminal 14.
  • Page 16: Made In Italy

    MADE IN ITALY King Gates S.r.l. Via A. Malignani, 42 - 33077 Sacile (PN) ITALY Tel. +39 0434 737082 - Fax +39 0434 785351 e-mail: info@king-gates.com web: www.king-gates.com...