Table of Contents

Advertisement

ISO 9001:2000
Cert. N°4500/1

User Manual

SDT200UB /SDT500UB
External Document

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SDT200UB and is the answer not in the manual?

Questions and answers

Summary of Contents for SCREEN SERVICE SDT200UB

  • Page 1: User Manual

    ISO 9001:2000 Cert. N°4500/1 User Manual SDT200UB /SDT500UB External Document...
  • Page 2: Table Of Contents

    ISO 9001:2000 Cert. N°4500/1 Table of Contents Document structure ....................... 7 Scope of the document ......................8 Introduction ........................... 9 Digitizer features ......................11 Satellite receivers features ..................... 11 3.2.1 DVB-S/S2 ........................ 11 3.2.2 DVB-S/S2 plus CAM ....................12 Terrestrial receivers features ..................13 3.3.1 DVB-T/T2 .......................
  • Page 3 ISO 9001:2000 Cert. N°4500/1 Output Interfaces ......................28 Control Interfaces ......................31 4.3.1 RS232 pinout ......................32 4.3.2 TLC pinout ......................32 4.3.3 TLS pinout ......................33 Power Supply ........................34 Environmental Specification ..................36 Mechanical Specification....................36 Java Graphic User Interface ....................37 Authentication Option ....................
  • Page 4 ISO 9001:2000 Cert. N°4500/1 5.7.1 DVB-T Settings ..................... 115 5.7.2 DVB-T Modulation ....................123 5.7.2.1 DVB-T Modulation: Modulator manager ............124 5.7.2.1.1 Network Synchronization parameters setting ............124 5.7.2.2 DVB-T Modulation: Modulation Parameters ..........128 5.7.2.3 DVB-T Modulation: DVB-H Parameters ............131 5.7.2.4 DVB-T Modulation: MIP Functions ..............
  • Page 5 ISO 9001:2000 Cert. N°4500/1 5.11 Manual compensation ....................316 5.11.1 Linear Precorrection .................... 316 5.11.2 Non Linear Precorrection ..................318 5.11.3 Port 5000 connection ..................319 5.12 Adaptive compensation ....................320 5.12.1 Linear Adaptive Precorrection ................320 5.12.1.1 Adaptive Filter ....................321 5.12.1.2 Adaptive Linear Precorrection: Management panel ........
  • Page 6 ISO 9001:2000 Cert. N°4500/1 LCD Alarms ........................392 SNMP – Simple Network Management Protocol ............... 397 SNMP Protocol Preferences ..................398 Monitoring ........................399 Events Monitoring ......................435 Configuring alarm masks and alarm thresholds ............436 7.4.1 Alarms Table ......................436 7.4.2 Thresholds Table....................
  • Page 7: Document Structure

    ISO 9001:2000 Cert. N°4500/1 1 Document structure This ARK6 User Manual has the following chapters and appendices:  Chapter 1 – Document structure.  Chapter 2 – Scope of the document.  Chapter 3 – Introduction This chapter contains an overview of ARK6 and its features. ...
  • Page 8: Scope Of The Document

    ISO 9001:2000 Cert. N°4500/1 2 Scope of the document Purpose of this document is to provide a comprehensive description of the functionalities of the SDT Series ARK-6 and to provide operating information on the software elements of the ARK6 system. SDT ARK6 User Manual provides software setup information and includes an overview of Java, SNMP and Local user interfaces.
  • Page 9: Introduction

    ISO 9001:2000 Cert. N°4500/1 3 Introduction The SDT ARK-6 Series has been designed as a brand new model of software defined transmitters which incorporate all the technical and functional capabilities of the previous models of the ARK-1 family (ARK- 1, ARK-R, ARK-T, ARK-ATSC, ECHO-2) together with a complete set of new functionalities that bring the transmitter at the forefront of the technology edge.
  • Page 10: Table 1. Hardware Options

    ISO 9001:2000 Cert. N°4500/1 Table 1. Hardware options Modulation Front-End DVB-T/H DVB-T2 ISDBT ATSC None Transmitter Transmitter Transmitter Transmitter Transmitter Transmitter Transmitter Transmitter Transmitter DVB-S/S2 with DVB-S/S2 RF input with DVB-S/S2 RF input with DVB-S/S2 RF input with DVB-S/S2 RF input Transmitter Transmitter Transmitter...
  • Page 11: Digitizer Features

    ISO 9001:2000 Cert. N°4500/1 3.1 Digitizer features Supports the A/D conversion and decoding of NTSC and PAL CVBS inputs Supports 2 CVBS video and 2 L/R audio inputs Adaptive 2-D, 5-line, adaptive comb filter Automatic video standard detection (NTSC/PAL) Automatic video standard switching Luma-peaking with programmable gain 3.2 Satellite receivers features 3.2.1 DVB-S/S2...
  • Page 12: Dvb-S/S2 Plus Cam

    ISO 9001:2000 Cert. N°4500/1 3.2.2 DVB-S/S2 plus CAM Input DVB-S and DVB-S2 demodulator that conforms to ETSI EN 300 421 and ETSI TR 102 376 respectively. Dual multi standard demodulation:  Legacy DVBS and DirecTVTM QPSK  DVBS2 QPSK, 8PSK, 16 and 32APSK ...
  • Page 13: Terrestrial Receivers Features

    ISO 9001:2000 Cert. N°4500/1 3.3 Terrestrial receivers features 3.3.1 DVB-T/T2 Agile VHF/UHF input Down-conversion (from 50.5 MHz up to 862 MHz) Input adjustable offset frequencies: from -200 kHz to +200 kHz (1 Hz step) Input combined DVB-T2 and DVB-T demodulator that conforms to the ETSI EN 302 755 and ETSI EN 300 744 standards that supports: ...
  • Page 14: Isdbt

    ISO 9001:2000 Cert. N°4500/1 3.3.2 ISDBT Agile VHF/UHF input Down-conversion (from 50.5 MHz up to 862 MHz) Input adjustable offset frequencies: from -200 kHz to +200 kHz (1 Hz step) Input ISDB-T demodulator that conforms to the ARIB STD-B31: 2005 standard Supports 1-segment / 3-segment reception of digital terrestrial sound broadcasting.(ISDB-Tsb) Auto-detect of transmission mode/ guard interval Incorporates TMCC decode circuit...
  • Page 15: Dvb-T2 Transmitter Features

    ISO 9001:2000 Cert. N°4500/1 3.4 DVB-T2 Transmitter features The ARK-6 DVB-T2 is an ETSI EN 302 755 (Second Generation Terrestrial) compliant Transmitter. The key features of the ARK-6 DVB-T2 are:  Standard MPEG-2 TS encapsulated T2-MI inputs (ETSI TS 102 773) over ASI (EN-50083/9) and Gigabit Ethernet (PRO-MPEG COP3 R2);...
  • Page 16: Dvb-T2 Signal Processing

    ISO 9001:2000 Cert. N°4500/1 3.4.2 DVB-T2 Signal Processing Input stream monitoring T2-MI over ASI, IP and RF supported PCR restamping Null packets deletion Bit rate adaptation through Null packets insertion PAT and PMT parsing for automatic detection of T2-MI PID User selectable input autoswitch criteria based on primary feed quality (RF, ASI and TSoIP) Linear and Non-Linear Adaptive Precorrections 3.4.3 DVB-T2 Supported Modes...
  • Page 17: Dvb-T Transmitter Features

    ISO 9001:2000 Cert. N°4500/1 3.5 DVB-T Transmitter features The ARK-6 DVB-T is an ETSI EN 300 744 compliant Transmitter. The key features of the ARK-6 DVB-T are:  MPEG-2 Transport Stream inputs (ISO 13818-1) over ASI (EN-50083/9), Gigabit Ethernet (PRO-MPEG COP3 R2); ...
  • Page 18: Dvb-T Supported Modes

    ISO 9001:2000 Cert. N°4500/1 3.5.3 DVB-T Supported Modes Guard intervals 1/4, 1/8, 1/16, 1/32 Constellations QPSK, 16-QAM, 64-QAM 2K, 4K, 8K Code Rate 1/2, 2/3, 3/4, 4/5, 5/6, 7/8 Network modes MFN and SFN Bandwidth 8 MHz, 7 MHz and 6 MHz Time Interleaver Adjustable Hier.
  • Page 19: Isdb-T Transmitter Features

    ISO 9001:2000 Cert. N°4500/1 3.6 ISDB-T Transmitter features The ARK-6 ISDB-T is an ARIB STD-B31: 2005 compliant Transmitter with Remux options. The key features of the ARK-6 ISDB-T are:  BTS (Broadcast TS, ABNT NBR 15601) inputs over ASI (EN-50083/9) and Gigabit Ethernet (PRO- MPEG COP3 R2) –...
  • Page 20: Isdb-T Supported Modes

    ISO 9001:2000 Cert. N°4500/1 3.6.3 ISDB-T Supported Modes Guard intervals 1/4, 1/8, 1/16, 1/32 Constellations QPSK, 16-QAM, 64-QAM Mode (FFT carriers) Mode 3 Code Rate 1/2, 2/3, 3/4, 4/5, 5/6, 7/8 Network modes MFN and SFN Bandwidth 6 MHz Time Interleaver 0, 1, 2, 4 Hier.
  • Page 21: Itu Transmitter Features

    ISO 9001:2000 Cert. N°4500/1 3.7 ITU Transmitter features The ARK-6 ITU is an ITU-R BT.470-6 compliant Transmitter. The key features of the ARK-6 ITU are:  Standard SDI inputs (SMPTE 259M-C – Component 4:2:2);  Agile UHF output Up-converter (from 470 MHz up to 862 MHz). The VHF option is also available. ...
  • Page 22: Itu Signal Processing

    ISO 9001:2000 Cert. N°4500/1 3.7.2 ITU Signal Processing Digital audio channels presence and level monitoring. Analog audio sampling rate fixed to 48 kHz. Input redundancy provided by an input autoswitch algorithm based on primary feed presence (SDI and CVBS). Selectable Group Delay curve. Selectable Audio Type.
  • Page 23: Atsc Transmitter Features

    ISO 9001:2000 Cert. N°4500/1 3.8 ATSC Transmitter features The ARK-6 ATSC is an A/53 and A/153 compliant Transmitter. The key features of the ARK-6 ATSC are:  SMPTE-310M with 19.39 Mbps, DVB-ASI (EN-50083/9) and Gigabit Ethernet (PRO-MPEG COP3 R2) inputs; ...
  • Page 24: System Features

    ISO 9001:2000 Cert. N°4500/1 3.9 System Features Synchronization External or GPS Internal clock Oven Controlled OCXO oscillator (10 MHz and 1 PPS) Output clock 1 PPS and 10 MHz Management Embedded SNMP v1/2 server Embedded Web server GbE Ports GbE 1: 10/100/1000 Base T Management port GbE 2: 10/100/1000 Base T Data port Security Authentication for GUI access supported.
  • Page 25: Specifications

    ISO 9001:2000 Cert. N°4500/1 4 Specifications 4.1 Input Interfaces ASI/SSI/SDI Number of inputs Connector 75 Ohm Input voltage 800 mVpp (500 to 1200 mVpp) Supported standards CEI EN 50083-9 SMPTE 310M SMPTE 259M TSoIP Number of channels Connector RJ45 Speed 10/100/1000 Number of inputs Connector...
  • Page 26 ISO 9001:2000 Cert. N°4500/1 CVBS Number of inputs Connector 75 Ohm Input Voltage 1 Vpp Supported standards NTSC Analog Audio Number of inputs 2 L/R Connector XLR3 (Cannon f) 600 Ohm balanced Input level +6dBm +/- 6 dB Supported standards EIA RF-297-A Number of inputs Connector...
  • Page 27 ISO 9001:2000 Cert. N°4500/1 1PPS Number of inputs Connector 50 Ohm Input voltage TTL (min 1,7 V) Pulse width 100 us Linear Precorrection Number of inputs Connector 50 Ohm Input level -20 to +11,5 dBm Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 27 of 468...
  • Page 28: Output Interfaces

    ISO 9001:2000 Cert. N°4500/1 4.2 Output Interfaces Number of outputs 1 Connector N Female Frequency UHF (VHF optional) Zout 50 Ohm Spectrum polarity Non-inverted (inverted optional) Harmonic and spurious <-50dBm below 1 GHz Digital Level SDTx200: 18 to 38 dBm SDTx500: 21 to 41,9 dBm SDTx201: SDTx501: 36 to 56 dBm...
  • Page 29 ISO 9001:2000 Cert. N°4500/1 TSoIP Number of channels Connector RJ45 Speed 10/100/1000 Standard PRO-MPEG COP3 R2 ASI Out Monitor Number of outputs Connector Zout 75 Ohm Output voltage 800 mVpp (500 to 1200 mVpp) Supported standards CEI EN 50083-9 SMPTE 310M SMPTE 259M RF Mon Number of outputs...
  • Page 30 ISO 9001:2000 Cert. N°4500/1 1PPS Number of outputs Connector Zout 50 Ohm Output voltage TTL (min 2,4 V) Pulse width 100 us Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 30 of 468...
  • Page 31: Control Interfaces

    ISO 9001:2000 Cert. N°4500/1 4.3 Control Interfaces GbE 1 RS485 Number of interfaces Number of interfaces Connector RJ45 Connector Speed 10/100/1000 Type CAM BUS (Not available) OPTO Relays Number of outputs Number of outputs Connector SUB-D 15p Female Connector SUB-D 25p Female Max current -5 mA Max voltage...
  • Page 32: Rs232 Pinout

    ISO 9001:2000 Cert. N°4500/1 4.3.1 RS232 pinout Usually personal computers use a standard RS 232 DE-9 connector. Figure 1. DE-9 Male connector Table 2. RS232 DE-9 pinout DE-9 Pin Name Direction Description Receive Data Transmit Data System Ground 4.3.2 TLC pinout ARK6 has a SUB-D 15p Female connector for OPTOs with customized pin assignments.
  • Page 33: Tls Pinout

    ISO 9001:2000 Cert. N°4500/1 4.3.3 TLS pinout ARK6 has a SUB-D 25p Female connector for Relays with customized pin assignments. Figure 3. TLS connector Table 4. TLS pinout Signal Signal RL_NC0 RL0_NC0 RL_COM0 RL0_COM0 RL_NO0 RL0_NO0 RL_NC1 RL1_NC1 RL_COM1 RL1_COM1 RL_NO1 RL1_NO1 RL_NC2...
  • Page 34: Power Supply

    ISO 9001:2000 Cert. N°4500/1 4.4 Power Supply 80 – 264 VAC Voltage 50 – 60 Hz Frequency ARK6 1U Mains Consumption [Test on ch. 21] MODE PWR [dBm] Vac [Volt] Iac[Amp] Consumption [W] ST-BY 0,35 78,8 Power OFF 0,40 90,0 Power ON 0,62 139,5...
  • Page 35 ISO 9001:2000 Cert. N°4500/1 ARK6 3U Mains Consumption [Test on ch. 45] MODE PWR [dBm] Vac [Volt] Iac[Amp] Consumption [W] ST-BY 0,35 78,8 Power OFF 0,40 90,0 Power ON Power ON 1010 Power ON 1280 Power ON 1530 Power ON 56 (1) 1660 Note to the table:...
  • Page 36: Environmental Specification

    ISO 9001:2000 Cert. N°4500/1 4.5 Environmental Specification Climatic Temperature range operating 0 °C to +40 °C (+32 °F to +104 °F) Temperature range within specs +5 °C to +45 °C (41 °F to +113 °F) Temperature range storage -30 °C to +70 °C (-22 °F to +158 °F) Humidity operating max 90% RH Compliant to EN50022 (emission)
  • Page 37: Java Graphic User Interface

    ISO 9001:2000 Cert. N°4500/1 5 Java Graphic User Interface The Java Graphic User Interface, stored in the board File System, is downloaded to the local PC every time the user connects to the board with a Web Browser. A proper Java Virtual Machine is needed; refer to the Appendix B for a description of supported Java and Internet Browsers.
  • Page 38: Java Menu Bar

    ISO 9001:2000 Cert. N°4500/1 5.2 Java Menu Bar The following figure shows the menu bar of the Java Graphic User Interface. It allows the switching between control pages that will be described in detail in next chapters. Figure 5. Java menu bar The following controls are provided: System commands bar allows to enable of the following commands: ...
  • Page 39: Figure 7. Operation Pages Bar

    ISO 9001:2000 Cert. N°4500/1  Network: allows to monitor the Network settings of both GbE port 1 and GbE port 2 and to set in/out Ethernet channels parameters.  GPS: shows received GPS statistics and provides commands to manage the Holdover functionality.
  • Page 40: Home Page

    ISO 9001:2000 Cert. N°4500/1 5.3 Home Page Click on Home Page button, highlighted in the next figure, to access the Home Page. Figure 9. Home Page window The Home Page provides a general description of the equipment, the firmware updating status and a subset of commands here below described: ...
  • Page 41: Input

    ISO 9001:2000 Cert. N°4500/1 5.4 Input Click on Input button, highlighted in the next figure, to monitor the input statistics window. Figure 10. ATSC / DVB-T/T2 Input window Figure 11. ISDB-T Input window Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 41 of 468...
  • Page 42: Figure 12. Itu Input Window

    ISO 9001:2000 Cert. N°4500/1 Figure 12. ITU Input window The Input window allows to monitor Transport Stream and SDI input statistics and to enable the cable equalizer bypass of each one of them. Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 42 of 468...
  • Page 43: Table 5. Input Window

    ISO 9001:2000 Cert. N°4500/1 Table 5. Input window Parameter / Control Description Admitted Ranges / Values Word rate Input word rate. Approximately 27 Mword/s Tuner Word rate Input byte rate. ASI - Tuner Bitrate Input bitrate.  Zero when the input has not been selected ...
  • Page 44 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  TS input overflow indicator. This alarm condition occurs when the Red: Alarm On ASI - Tuner Overflow input bit-rate exceeds the capability of the modulation (Ref. to ETSI ...
  • Page 45 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Input GbE overflow alarm status. This alarm condition occurs when GbE 2– Red: Alarm on Overflow the input bit-rate exceeds the capability of the modulation (Ref. to ...
  • Page 46 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  NTSC 4:2:2 component video;  NTSC 4:2:2 16x9 component video;  NTSC 4:4:4 13,5 MHz component video; SDI 1/2/3/4 Standard Shows the video standard detected for the SDI input. ...
  • Page 47: Front-End

    ISO 9001:2000 Cert. N°4500/1 5.5 Front-End Click on Front-End button, highlighted in the next figure, to access the tuner window. Figure 13. Front-End window Use the Tuner window to monitor input channel, frequency offset, signal level and quality, and to monitor the RF input demodulation parameters.
  • Page 48: Tuner Window: Rf Power Level Monitor

    ISO 9001:2000 Cert. N°4500/1 5.5.1 Tuner window: RF power level monitor Figure 14. Tuner window: RF power level monitor Table 6. Tuner window: RF power level monitor Parameter / Control Description Admitted Ranges / Values   Rx Level [dBm] / Min: -84 Low Power General...
  • Page 49: Dvb-T/T2 Fe Type

    ISO 9001:2000 Cert. N°4500/1 5.5.2 DVB-T/T2 FE Type 5.5.2.1 DVB-T2 RF Input: Status and demodulation parameters Status and demodulation parameters tab shows L1 signalling data of the input RF signal. Figure 15. DVB-T2 RF Input: Status and demodulation parameters Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 49 of 468...
  • Page 50: Table 7. Dvb-T2 Rf Input: Status And Demodulation Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 7. DVB-T2 RF Input: Status and demodulation parameters Parameter / Control Description Admitted Ranges / Values Status Carrier Offset [kHz] Carrier offset of the currently tuned channel Status IF AGC Level Input IF AGC level Status RF AGC Level Input RF AGC level...
  • Page 51 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min: 0 Status LDPC Iterations per minute LDPC iterations per minute.  Max: 255 Status Pre BCH FER Post BCH FER (FEC block error rate). Status Pre BCH BER Pre BCH BER.
  • Page 52 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  T2_SISO The preamble is a T2 preamble and the P2 part is transmitted in its SISO format  T2_MIMO L1-Pre S1_field This field indicates the preamble format. The preamble is a T2 preamble signalling and the P2 part is transmitted in...
  • Page 53 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  1/32  1/16  L1-Pre This field indicates the guard interval of the symbols in the T2-  GUARD_INTERVAL signalling frame.  1/128  19/128  19/256 When T2_VERSION = ‘0000’: ...
  • Page 54 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Not Mixed All preambles in the current transmission are of the same type L1-Pre This field indicates whether the preambles are all of the same as this preamble. Mixed Indicator signalling type or not.
  • Page 55 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values     L1-Pre This field indicates the scattered pilot pattern used for the data  PILOT_PATTERN signalling OFDM symbols.     Reserved for future use. ...
  • Page 56 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min: 0 L1-Pre This field uniquely identifies a T2 system within the DVB network T2_SYSTEM_ID signalling (identified by NETWORK_ID).  Max: 65535  Min: 2 L1-Pre NUM_T2_FRAME This field indicates the number of T2-frames per super-frame.
  • Page 57 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values L1-Post  Min: 0 This field indicates the number of auxiliary streams. Zero means signalling NUM_AUX no auxiliary streams are used.  Max: 15  Min: 0 – TX-SIG L1-Post This field indicates the type of the current auxiliary streams.
  • Page 58 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Common PLP This field indicates the type of the associated PLP.  L1-Post DATA PLP Type 1 If value of the PLP_TYPE field is one of the values reserved for signalling future use, the total number of bits in the PLP loop shall be the PLP_TYPE...
  • Page 59 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values L1-Post This field indicates the IDX of the first frame of the super-frame in  Min: 0 signalling FIRST_FRAME_IDX which the current PLP occurs. The value of FIRST_FRAME_IDX ...
  • Page 60 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  16K LDPC L1-Post  64K LDPC signalling PLP_FEC_TYPE This field indicates the FEC type used by the associated PLP.  From 2 to 3: Reserved for future L1-Post ...
  • Page 61 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values L1-Post  IN-BAND_A_FLAG / Type A/B sig. is not carried This 1-bit field indicates whether the current PLP carries in-band signalling signalling information.  IN-BAND_B_FLAG Type A/B sig. is carried ...
  • Page 62: Dvb-T Rf Input: Status And Demodulation Parameters

    ISO 9001:2000 Cert. N°4500/1 5.5.2.2 DVB-T RF Input: Status and demodulation parameters Status and demodulation parameters tab shows L1 signalling data of the input RF signal. Figure 16. DVB-T RF Input: Status and demodulation parameters Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 62 of 468...
  • Page 63: Table 8. Dvb-T Rf Input: Status And Demodulation Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 8. DVB-T RF Input: Status and demodulation parameters Parameter / Control Description Admitted Ranges / Values Status Carrier Offset [kHz] Carrier offset of the currently tuned channel Status IF AGC Level Input IF AGC level Status RF AGC Level Input RF AGC level...
  • Page 64 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values Status Pre RS BER Pre Reed Solomon correction byte error rate. Status RS Error Count Reed Solomon Error Count  Min: - 220 ppm Status PPM [ppm] Demodulated sampling frequency offset value-PPM [ppm] ...
  • Page 65 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  1/2;  2/3;  LP FEC LP stream code rate. 1/4;  5/6;  7/8.  1/32;  1/16; Guard interval Guard interval.  1/8;  1/4. ...
  • Page 66: Dvb-T/T2 Rf Input: Constellation

    ISO 9001:2000 Cert. N°4500/1 5.5.2.3 DVB-T/T2 RF Input: Constellation The constellation tab allows to plot the constellation of the received signal. Figure 17. DVB-T/T2 RF Input: Constellation tab Click on “Start Plot” to download I/Q data of the RF input signal. The total number of I/Q samples is given by the difference between “Max Value”...
  • Page 67: Table 9. Dvb-T/T2 Rf Input: Constellation Tab

    ISO 9001:2000 Cert. N°4500/1 Table 9. DVB-T/T2 RF Input: Constellation tab Parameter / Control Description Admitted Ranges / Values Constellation Start Plot Starts plotting the received signal. Constellation Stop Plot Stops plotting of the received signal Constellation Clear Plot Clears plotted constellation points. ...
  • Page 68: Isdb-T Fe Type

    ISO 9001:2000 Cert. N°4500/1 5.5.3 ISDB-T FE Type The Tuner panel for the ISDB-T Front-End shows the status of the demodulator, the input modulation parameters and the received signal quality. Figure 18. ISDB-T RF Input: Status and demodulation parameters Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 68 of 468...
  • Page 69: Table 10. Isdb-T Rf Input: Status And Demodulation Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 10. ISDB-T RF Input: Status and demodulation parameters Parameter / Control Description Admitted Ranges / Values Status IF Level Input IF level Status IF AGC DAC Input RF AGC DAC level Sync statistics on both FE and Meas boards show the synchronization state of the ISDB-T demodulators.
  • Page 70 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values    Layer A/B/C Coding Rate Of Inner Code Coding rate of inner code    Unused Hierarchical Layer  0 (mode 1); 0 (mode 2); 0 (mode ...
  • Page 71 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  1 Segment  2 Segment  3 Segment  4 Segment  5 Segment  6 Segment  7 Segment Layer A/B/C Number Of Segments Number of segments ...
  • Page 72: Digitizer Fe Type

    ISO 9001:2000 Cert. N°4500/1 5.5.4 DIGITIZER FE Type This page shows the available statistics for the analog input video. Figure 19. CVBS Inputs: Statistics Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 72 of 468...
  • Page 73: Table 11. Cvbs Inputs: Statistics

    ISO 9001:2000 Cert. N°4500/1 Table 11. CVBS Inputs: Statistics Parameter / Control Description Admitted Ranges / Values Enable the PAL compensation on digitized video. This features  Enabled A/D PAL General should be enabled only for particular application e.g. the external Compensation ...
  • Page 74: Atsc Fe Type

    ISO 9001:2000 Cert. N°4500/1 5.5.5 ATSC FE Type The Tuner panel for the ATSC Front-End shows the status of the demodulator, the input modulation parameters and the received signal quality. Figure 20. ATSC RF Input: Status and demodulation parameters Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 74 of 468...
  • Page 75: Table 12. Atsc Rf Input: Status And Demodulation Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 12. ATSC RF Input: Status and demodulation parameters Parameter / Control Description Admitted Ranges / Values  Reset  Reset Wait  AGC Wait 1  AGC Wait 2  Carrier Synchro  NCO Loop General VSB Demod Status VSB demodulation status.
  • Page 76 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  General Green: Locked Demodulator Lock Demodulator lock status  Grey: Unlocked  General Green: Locked Digital AGC Lock Digital AGC lock status.  Grey: Unlocked  General Green: Locked Frame Lock Indicator Frame lock status.
  • Page 77: Dvb-S2 Fe Type

    ISO 9001:2000 Cert. N°4500/1 5.5.6 DVB-S2 FE Type Figure 21. DVB-S2 FE Type: Input statistics Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 77 of 468...
  • Page 78: Dvb-S2 Cam Fe Type

    ISO 9001:2000 Cert. N°4500/1 5.5.7 DVB-S2 CAM FE Type Figure 22. DVB-S2 CAM FE Type: Tuner Figure 23. DVB-S2 CAM FE Type: Descrambler Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 78 of 468...
  • Page 79: Dvb-T2

    ISO 9001:2000 Cert. N°4500/1 5.6 DVB-T2 Click on DVB-T2 button, highlighted in the next figure, to access the DVB-T2 window. Figure 24. DVB-T2 window Use the DVB-T2 Processing page to manage DVB-T2 specific configuration parameters and to monitor output signal level and quality. Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 79 of 468...
  • Page 80: Dvb-T2 Settings

    ISO 9001:2000 Cert. N°4500/1 5.6.1 DVB-T2 Settings Click on the DVB-T2 Settings button, highlighted in the next figure, to access the DVB-T2 general settings. Figure 25. DVB-T2 Processing: DVB-T2 Settings Use the DVB-T2 Settings page to select inputs, to set input/output RF channels, offset frequencies, Frontend and Measure alarm thresholds and to manage Input Autoswitch functionality (refer to Appendix A for further information).
  • Page 81: Table 13. Dvb-T2 Processing: Dvb-T2 Settings

    ISO 9001:2000 Cert. N°4500/1 Table 13. DVB-T2 Processing: DVB-T2 Settings Parameter / Control Description Admitted Ranges / Values  ASI 1  ASI 2 Input selector.  ASI 3 It is not allowed to change input until the Input Autoswitch is ...
  • Page 82 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min: 0 s Primary to Secondary Primary to secondary input switch countdown expressed in  Input Autoswitch Max: *.def file dependant Switch Counter seconds.  Default: 25 s ...
  • Page 83 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min: -200 kHz Output Offset [Hz] Output frequency offset (expressed in Hz).  Max: +200 kHz Output power ranges are device’s Output Power [dBm] Output power (expressed in dBm). definition dependant.
  • Page 84 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min: 0 MEAS Alarm LDPC Mean Err Thr Meas LDPC Mean Error alarm threshold Thresholds  Max: 255  Min: 0 MEAS Alarm Pre LDPC BER Thr Meas Pre LDPC BER alarm threshold Thresholds ...
  • Page 85: Dvb-T2 Modulation

    ISO 9001:2000 Cert. N°4500/1 5.6.2 DVB-T2 Modulation The DVB-T2 Modulation window allows actual modulation parameters monitoring and setting. Figure 26. DVB-T2 Processing: DVB-T2 Modulation The DVB-T2 Modulation window is composed by the following sections:  Modulator manager;  L1-pre signalling data; ...
  • Page 86: Dvb-T2 Modulation: Modulator Manager

    ISO 9001:2000 Cert. N°4500/1 5.6.2.1 DVB-T2 Modulation: Modulator manager Commands and indicators belonging to this section allow to:  Select the network mode;  Enable test signals;  Monitor the data rate achieved through the current modulation parameters;  Manage the Modulator Interface; ...
  • Page 87: T2-Mi Pid Management

    ISO 9001:2000 Cert. N°4500/1 The “Automatic Regeneration” function allows to retrieve the configuration data from the input demodulator. The three options provided by “Automatic Regeneration” selector are:  OFF: the function is not used;  ON – Auto Regen_Flag: the configuration is automatically retrived from the demodulated L1 data and the REGEN_FLAG field is automatically incremented.
  • Page 88: Table 14. Dvb-T2 Modulation: Modulator Manager

    ISO 9001:2000 Cert. N°4500/1 Table 14. DVB-T2 Modulation: Modulator manager Parameter / Control Description Admitted Ranges / Values  Selector of Network’s Transmitters Synchronization. MFN / SFN MFN/SFN   Checked: Enabled MFN / SFN Delete Null Packets Delete null packets enabling check box. ...
  • Page 89 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  VV002  VV003  VV012  VV013 Config Preset Config Num Preset configuration selector. Management  VV015  VV016  VV018-GROUP1  Vv018-GROUP2 Configuration change indicator notifies that some parameters have been changed and that the current configuration has not been ...
  • Page 90 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values Manual setting of the PID of incoming TS packets encapsulating  Min: 0 T2-MI PID T2-MI packets. T2-MI PID Management  Max: 8191 It is used only when the T2-MI PID Mode Status is Manual. ...
  • Page 91: Dvb-T2 Modulation: L1-Pre Signalling Data

    ISO 9001:2000 Cert. N°4500/1 5.6.2.2 DVB-T2 Modulation: L1-pre signalling data When the “Parameters source” selector is put on “Local Parameters”, L1 PRE tab allows to:  Set L1-pre signalling data;  Monitor currently used L1-pre signalling data. Figure 28. DVB-T2 Modulation: L1-pre signalling data 1 Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 91 of 468...
  • Page 92: Figure 29. Dvb-T2 Modulation: L1-Pre Signalling Data 2

    ISO 9001:2000 Cert. N°4500/1 When the “Parameters source” selector is put on “T2-MI Parameters”, L1 PRE tab allows to monitor the currently used L1-pre signalling data decoded from incoming T2-MI packets. Figure 29. DVB-T2 Modulation: L1-pre signalling data 2 Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 92 of 468...
  • Page 93 ISO 9001:2000 Cert. N°4500/1 Table 15. DVB-T2 Modulation: L1-pre signalling data Parameter / Control Description Admitted Ranges / Values  Group 1  General MISO Group This selector allows The MISO group to be set. Group 2  None General Time Offset [100ns] User time offset setting.
  • Page 94 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  T2_SISO The preamble is a T2 preamble and the P2 part is transmitted in its SISO format  T2_MIMO Local/Used/T2- S1_field This field indicates the preamble format. The preamble is a T2 preamble and the P2 part is transmitted in its MISO format...
  • Page 95 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  1/32  1/16  Local/Used/T2- This field indicates the guard interval of the symbols in the T2-  GUARD_INTERVAL frame.  1/128  19/128  19/256 When T2_VERSION = ‘0000’: ...
  • Page 96 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Not mixed All preambles in the current transmission are of the same type Local/Used/T2- This field indicates whether the preambles are all of the same type as this preamble. Mixed Indicator or not.
  • Page 97 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values     Local/Used/T2- This field indicates the scattered pilot pattern used for the data  PILOT_PATTERN OFDM symbols.     Reserved for future use. ...
  • Page 98 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min: 0 Local/Used/T2- This field uniquely identifies a T2 system within the DVB network T2_SYSTEM_ID (identified by NETWORK_ID).  Max: 65535  Min: 2 Local/Used/T2- NUM_T2_FRAME This field indicates the number of T2-frames per super-frame. ...
  • Page 99: Dvb-T2 Modulation: L1-Post Configurable Signalling Data

    ISO 9001:2000 Cert. N°4500/1 5.6.2.3 DVB-T2 Modulation: L1-post configurable signalling data When the “Parameters source” selector is put on “Local Parameters”, L1 POST CONF tab allows to:  Set L1-post configurable signalling data;  Monitor currently used L1-post configurable signalling data. Figure 30.
  • Page 100: Figure 31. Dvb-T2 Modulation: L1-Post Configurable Signalling Data 2

    ISO 9001:2000 Cert. N°4500/1 When the “Parameters source” selector is put on ”T2-MI Parameters”, L1 POST CONF tab allows to:  Monitor and set L1-post configurable signalling data of the local configuration; this configuration will be applied if and only if “Parameters source” selector is set to “Local Parameters”;...
  • Page 101: Table 16. Dvb-T2 Modulation: L1-Pre Signalling Data

    ISO 9001:2000 Cert. N°4500/1 Table 16. DVB-T2 Modulation: L1-pre signalling data Parameter / Control Description Admitted Ranges / Values  Min: 1 This field indicates the total number of sub-slices for the type 2  Max: Allowable values of this field Local/Used/T2-MI SUB_SLICES_PER_FRAME data PLPs across all RF channels in one T2-frame.
  • Page 102 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  This field indicates the length of the associated FEF part as the Min: 0 Local/Used/T2-MI FEF_LENGTH number of elementary periods T, from the start of the P1 symbol ...
  • Page 103 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values Local - PLP Add PLP Common Adds a PLP with Common as PLP_TYPE. Local - PLP Add PLP Type 1 Adds a PLP with Type 1 as PLP_TYPE. Local - PLP Add PLP Type 2 Adds a PLP with Type 2 as PLP_TYPE.
  • Page 104 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  0: inter-frame TFS is applied as described in annex E of ETSI EN This field is set to '1' if a PLP of type 1 in a TFS system occurs on Local/Used/T2-MI 302 755, or no meaning, TFS is the same RF channel in each T2-frame.
  • Page 105 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values    Local/Used/T2-MI –  PLP_COD This field indicates the code rate used by the associated PLP. PLP –  PLP Parameters   From 6 to 7: Reserved for future ...
  • Page 106 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values Local/Used/T2-MI –  Min: 1 This field indicates the maximum value of PLP_NUM_BLOCKS PLP_NUM_BLOCKS_MAX PLP – for this PLP.  Max: 1023 PLP Parameters Local/Used/T2-MI –  Min: 1 This field indicates the T2-frame interval within the super-frame FRAME_INTERVAL PLP –...
  • Page 107 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Type A/B sig. is not carried: In- Local/Used/T2-MI band signalling information is not – IN-BAND_A_FLAG / This 1-bit field indicates whether the current PLP carries in-band carried PLP –...
  • Page 108 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  GFPS  Local - PLP Input Stream Format Input stream format selector    Single Local - PLP SIS/MIS Single or multiple input streams selector  Multiple ...
  • Page 109 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values SYNCD indicator. Local - PLP SYNCD This field is visible only in Normal Mode. User Packet Length indicator. Local - PLP This field is visible only in Normal Mode. Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 109 of 468...
  • Page 110: Dvb-T2 Modulation: L1-Post Dynamic Signalling Data

    ISO 9001:2000 Cert. N°4500/1 5.6.2.4 DVB-T2 Modulation: L1-post dynamic signalling data When the “Parameters source” selector is put on ”Local Parameters”, L1 POST DYN tab allows to monitor the currently used L1-post dynamic signalling data. Figure 32. DVB-T2 Modulation: L1-post dynamic signalling data 1 When the “Parameters source”...
  • Page 111 ISO 9001:2000 Cert. N°4500/1 Table 17. DVB-T2 Modulation: L1-post dynamic signalling data Parameter / Control Description Admitted Ranges / Values  Min: 0 Used/T2-MI FRAME_IDX Index of the current T2-frame within a super-frame.  Max: 254 Used/T2-MI SUB_SLICE_INTERVAL Sub-slice interval. ...
  • Page 112: Dvb-T2 Measure

    ISO 9001:2000 Cert. N°4500/1 5.6.3 DVB-T2 Measure Click on Measure button, highlighted in the next figure, to access the measure window. Figure 34. DVB-T2-Measure: DVB-T2 Measure Use the Measure window to monitor output signal level and quality, to access L1-signalling decoding and active PLP information.
  • Page 113: Dvb-T2 Measure Window: Rf Power Level Monitor

    ISO 9001:2000 Cert. N°4500/1 5.6.3.1 DVB-T2 Measure window: RF power level monitor Figure 35. DVB-T2 Measure: RF power level monitor Table 18. DVB-T2 Measure: RF power level monitor Parameter / Control Description Admitted Ranges / Values This value is the level of the signal, passing through the Monitor Tx Level ...
  • Page 114: Dvb-T

    ISO 9001:2000 Cert. N°4500/1 5.7 DVB-T Click on DVB-T button, highlighted in the next figure, to access the DVB-T window. Figure 36. DVB-T window Use the DVB-T Processing page to manage DVB-T specific configuration parameters and to monitor output signal level and quality. Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 114 of 468...
  • Page 115: Dvb-T Settings

    ISO 9001:2000 Cert. N°4500/1 5.7.1 DVB-T Settings Click on the DVB-T Settings button, highlighted in the next figure, to access the DVB-T general setting. Figure 37. DVB-T Processing: DVB-T Settings Use the DVB-T Settings page to select inputs, to set input/output RF channels, offset frequencies, Frontend and Measure alarm thresholds and to manage Input Autoswitch and Seamless functionalities (refer to Appendix A for further information).
  • Page 116: Table 19. Dvb-T Processing: Dvb-T Settings

    ISO 9001:2000 Cert. N°4500/1 Table 19. DVB-T Processing: DVB-T Settings Parameter / Control Description Admitted Ranges / Values Input Autoswitch: HP/LP priority input selector.  ASI 1 It is not allowed to change input until the Input Autoswitch is  ASI 2 enabled.
  • Page 117 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  ASI 1  ASI 2  ASI 3  Input Autoswitch Actual Input Shows the currently used input. ASI 4  Tuner  GbE 2 ch1  GbE 2 ch2 ...
  • Page 118 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values VHF: UHF:   Tuner Channel Input RF channel selector. Min: E2 Min: 21   Max: E12 Max: 69  Min: - 200 kHz The receiver frequency will accept offset frequencies in the range Tuner Offset [Hz] +/- 200 kHz (1 Hz steps).
  • Page 119 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  HP/LP Input - Network Delay Min: 0 This monitor shows the Network Delay, measured analyzing MIP contained in the input. This delay is expressed in units of 100 ns. ...
  • Page 120 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values This flag enables the check of the MIP priority to force a switching  HP/LP Input - to the other input. Checked: Alarm enabled MIP Priority Error By disabling this rule the detection of the MIP priority Errors don’t ...
  • Page 121 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  HP/LP Input - Gray: alarm not present or masked Transport Error Flag Transport Error Flag rise this alarm  Input 1/2 Red: alarm raised  HP/LP Input - Gray: alarm not present or masked ASI word Error ASI word Error rise this alarm...
  • Page 122 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min: 0 FE Alarm PreViterbi BER Thr FE Pre Viterbi BER alarm threshold. Thresholds  Max: 1  Min: 10 dB FE Alarm MER Thr [dB] FE MER alarm threshold. Thresholds ...
  • Page 123: Dvb-T Modulation

    ISO 9001:2000 Cert. N°4500/1 5.7.2 DVB-T Modulation The DVB-T Modulation window allows actual modulation parameters monitoring and setting. Figure 38. DVB-T Modulation: DVB-T Modulation The DVB-T Modulation window is composed by the following sections:  Modulator manager;  Modulation Parameters; ...
  • Page 124: Dvb-T Modulation: Modulator Manager

    ISO 9001:2000 Cert. N°4500/1 5.7.2.1 DVB-T Modulation: Modulator manager Commands and indicators belonging to this section allow to:  Select the network mode;  Enable test signals;  Monitor the HP and LP MIPs status. Figure 39. DVB-T Modulation: Modulator manager 5.7.2.1.1 Network Synchronization parameters setting Four Network Synchronization modes are available: ...
  • Page 125: Table 20. Dvb-T Modulation: Configuration Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 20. DVB-T Modulation: Configuration parameters Parametro MFN MIP SFN Local Mode Local Local Constellation Local Local FEC HP Local Local FEC LP Local Local Transmission Local Local Time Slicing HP Local Local Time Slicing LP Local Local Guard Time...
  • Page 126: Table 21. Dvb-T Modulation: Modulator Manager

    ISO 9001:2000 Cert. N°4500/1 Table 21. DVB-T Modulation: Modulator manager Parameter / Control Description Admitted Ranges / Values  Selector of Network’s Transmitters Synchronization (ref. to Network Synchronization parameters setting paragraph).  MFN MIP MFN / SFN MFN/SFN Note: Seamless input switching mechanism works only in SFN and ...
  • Page 127 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  None The selector of test signal.  Test Note: PRBS Test and Force Null Packets test modes are available  Test Hole only when the Parameters Source selector is set to Local Parameters.
  • Page 128: Dvb-T Modulation: Modulation Parameters

    ISO 9001:2000 Cert. N°4500/1 5.7.2.2 DVB-T Modulation: Modulation Parameters These commands and indicators allow the setting of modulation parameters. This includes the monitoring of parameters carried by MIP in SFN configuration and of actual modulation parameters for Digital Re-transmitter mode. Note: ARK-T read only the modulation parameters of HP input MIP.
  • Page 129: Table 22. Dvb-T Modulation: Modulation Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 22. DVB-T Modulation: Modulation Parameters Parameter / Control Description Admitted Ranges / Values Transmission mode: set by MIP.   Local Mode Transmission mode: locally set.  Actual Current transmission mode Constellation for current modulation scheme: set by MIP. ...
  • Page 130 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  a=2; Actual Current Hierarchy information for current scheme.  a=4.  Guard interval: set by MIP. 1/32  1/16 Local Guard interval: locally set. Guard Time  Actual Current guard interval.
  • Page 131: Dvb-T Modulation: Dvb-H Parameters

    ISO 9001:2000 Cert. N°4500/1 5.7.2.3 DVB-T Modulation: DVB-H Parameters These commands and indicators allow the setting of options for DVB-H transmission, the monitoring of parameters carried by MIP in SFN configuration and of actual DVB-H options. Note: ARK-T read only the DVB-H parameters of HP input MIP. Figure 41.
  • Page 132: Table 23. Dvb-T Modulation: Dvb-H Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 23. DVB-T Modulation: DVB-H Parameters Parameter / Control Description Admitted Ranges / Values Enabling of time slice transmission of the HP/LP stream: set by MIP.  Used Time Slicing HP/LP Enabling of time slice transmission of the HP/LP stream: locally Local ...
  • Page 133: Dvb-T Modulation: Mip Functions

    ISO 9001:2000 Cert. N°4500/1 5.7.2.4 DVB-T Modulation: MIP Functions These commands and indicators allow the enabling and monitoring of MIP functions in SFN configuration, the setting of local functions and the monitoring of the actual functions used by modulator. Note: ARK-T read only the function of HP input MIP. Figure 42.
  • Page 134: Table 24. Dvb-T Modulation: Mip Functions

    ISO 9001:2000 Cert. N°4500/1 Table 24. DVB-T Modulation: MIP Functions Parameter / Control Description Admitted Ranges / Values MIP cell ID function enabling  Checked: Enabled Cell Id enable  General Cell Id enabling. Must be enabled to insert Cell Id into Not checked: Disabled Local output TPS.
  • Page 135 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values Used delay monitoring. In SFN this value is calculated adding the MIP max delay, the Local user delay, the MIP Time offset, the Local time offset and the Device delay ...
  • Page 136 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Checked: Enabled Local Tx ID Broadcast Enable Tx ID 0 enabling.  Not checked: Disabled  Min: 0 Local Tx ID User Tx ID setting.  Max: 65,535 ...
  • Page 137: Dvb-T Measure

    ISO 9001:2000 Cert. N°4500/1 5.7.3 DVB-T Measure Click on Measure button, highlighted in the next figure, to access the measure window. Figure 43. DVB-T Measure Use the Measure window to monitor output signal level and quality. The Measure window is composed by the following sections: ...
  • Page 138: Dvb-T Measure: Rf Power Level Monitor

    ISO 9001:2000 Cert. N°4500/1 5.7.3.1 DVB-T Measure: RF power level monitor Figure 44. DVB-T Measure: RF power level monitor Table 25. DVB-T Measure: RF power level monitor Parameter / Control Description Admitted Ranges / Values This value is the level of the signal, passing through the Monitor Tx Level ...
  • Page 139: Isdb-T

    ISO 9001:2000 Cert. N°4500/1 5.8 ISDB-T Click on ISDBT button, highlighted in the next figure, to access the ISDBT window. Figure 45. ISDBT window Use the ISDBT Processing page to manage ISDBT specific configuration parameters and to monitor output signal level and quality. Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 139 of 468...
  • Page 140: Isdb-T Settings

    ISO 9001:2000 Cert. N°4500/1 5.8.1 ISDB-T Settings Click on the ISDBT Settings button, highlighted in the next figure, to access the ISDBT general setting. Figure 46. ISDB-T Processing: ISDB-T Settings Use the ISDB-T Settings page to select inputs, to set the input RF channel, offset frequency, Frontend alarm thresholds and to manage Input Autoswitch facility.
  • Page 141: Table 26. Isdb-T Processing: Isdb-T Settings

    ISO 9001:2000 Cert. N°4500/1 Table 26. ISDB-T Processing: ISDB-T Settings Parameter / Control Description Admitted Ranges / Values  ASI 1  ASI 2 Input selector.  ASI 3 Allows to select a physical input for the modulator or to enable the remux mode ...
  • Page 142 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Enabled Enables the use of Input Autoswitch finite-state machine. Input Autoswitch Auto Input Enable Refer to Appendix A. for further information.  Disabled  ASI 1  ASI 2 ...
  • Page 143 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Priority Input Locked  Priority Input Not Locked Input Autoswitch State Current state of the finite-state machine  Searching First Input Locked  Check Priority Input VHF: UHF: ...
  • Page 144 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values Layer Statistic Layer C Layer B output bitrate indication. Available Bitrate Used in remux mode only Layer Statistic Layer A Layer A FIFO level FIFO level Used in remux mode only Layer Statistic Layer B Layer B FIFO level...
  • Page 145 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values Layer Statistic Layer A This alarm condition occurs when the input bitrate exceeds the  Red: Alarm on output bitrate Input 1/2  Grey: Alarm off Used in remux mode only Overflow Layer Statistic Layer B...
  • Page 146 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values SFN enabling. Only with SFN enable the maximum delay value is  SFN Enable written in the IIP. Synchronization ID  SFN Disable Used in remux mode only Maximum delay setting in 100ns per unit.
  • Page 147 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  FE Alarm Layer C Min: 0 [ISDBT] FE Pre-Viterbi BER High Layer C alarm threshold. Thresholds  PreViterbi BER Thr Max: 1  Min: 10 dB Measure Alarm CN Thr [dB] [ISDB-T] MEAS CN Low alarm threshold.
  • Page 148: Isdb-T Modulation

    ISO 9001:2000 Cert. N°4500/1 5.8.2 ISDB-T Modulation The ISDBT modulation page allows IIP and actual modulation parameters monitoring and modulator setting/monitoring. The modulation parameters can be chosen between the ones extrapolate from IIP and the ones locally set. The IIP parameters are available only from BTS or BTS tunneled data input, in other case the locally parameters must be used.
  • Page 149: Table 27. Isdb-T Modulation: Modulator Manager

    ISO 9001:2000 Cert. N°4500/1 Table 27. ISDB-T Modulation: Modulator manager Parameter / Control Description Admitted Ranges / Values  None   Force Null Packets A  Force Null Packets B  Enable test mode. Force Null Packets C Test Test ...
  • Page 150 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min: 0 Equipment ID Equipment ID setting.  Max: 4095  Green: Present Defined in IIP Flag monitoring if Equipment ID set is found in received IIP ...
  • Page 151 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  SFN Enabled Synchronization ID Shows the SFN/MFN from IIP  SFN Disabled  Min: 0x000000 Maximum delay parameter value from IIP. The value is shown in Maximum delay 100 ns units ...
  • Page 152 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values Actual Layer A Actual Layer B Current modulation scheme. Actual Layer C IIP Layer A IIP Layer B Coding rate of inner code: set by IIP.  IIP Layer C ...
  • Page 153 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  1 Segment  2 Segment  3 Segment  4 Segment  5 Segment  6 Segment IIP Layer A  7 Segment Number Of Segments Number of segments: set by IIP. IIP Layer B ...
  • Page 154: Cam (Pid Filter)

    ISO 9001:2000 Cert. N°4500/1 5.8.3 CAM (PID Filter) The ARK6 ISDB-T provides commands and monitoring that allows the manual filtering of each single PID contained in each logical input for a versatile re-multiplexing of one or more inputs. Click on CAM (PID Filter) button, highlighted in the next figure, to access the PID filtering and remapping window.
  • Page 155: Table 28. Cam (Pid Filter) Window

    ISO 9001:2000 Cert. N°4500/1 Table 28. CAM (PID Filter) window Parameter / Control Description Admitted Ranges / Values Layer A input 1/2 Layer B input 1/2 Refresh Click on Refresh button to refresh the list of blocked/passing PIDs. Layer C input 1/2 Layer A input 1/2 Select a PID through a left mouse click and then click on Add button Layer B input 1/2...
  • Page 156: Si/Psi Carousel

    ISO 9001:2000 Cert. N°4500/1 5.8.4 SI/PSI Carousel Click on SI/PSI Carousel button, highlighted in the next figure, to access the tables’ carousel information window. Figure 49. SI/PSI Carousel The SI/PSI Carousel window provides information about SI/PSI memory partitions status (Refer to Appendix A for further information).
  • Page 157: Iip

    ISO 9001:2000 Cert. N°4500/1 5.8.5 IIP Click on IIP button, highlighted in the next figure, to access the IIP SFN management window. Figure 50. IIP window This window allows to manage the equipment control information to insert in IIP in case of SFN transmission.
  • Page 158: Add

    ISO 9001:2000 Cert. N°4500/1 5.8.5.1 Add Click on the Add button to open the Add Equipment dialog box. Figure 51. Add dialog box The Add button is used to create new equipment control information loops. Table 30. Add dialog box Button Description Admitted Ranges /...
  • Page 159: Tables

    ISO 9001:2000 Cert. N°4500/1 5.8.6 Tables Click on the Tables icon, highlighted in the figure below, to access the Tables window. The Tables window allows to analyze the SI/PSI tables in each logical input TS, and to create, manage and store actual and new tables. Figure 52.
  • Page 160: Table 31. Tables Window

    ISO 9001:2000 Cert. N°4500/1 Table 31. Tables window Parameter / Control Description Admitted Ranges / Values Reads the SI/PSI tables from each logical input TS and allows the Input Read analysis of tables and descriptors. Shows in a tree fashion the hierarchy of input SI/PSI data. Each Input SI/PSI input tree table is shown as an expandable tree node to allow a precise...
  • Page 161 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values Allows removing an instance of a selected table from a local SI/PSI Carousel Layer A tree. It also allows deleting an instance of a descriptor from a Remove the selected selected table.
  • Page 162: Available Tables And Transmission Repetition Rates

    ISO 9001:2000 Cert. N°4500/1 5.8.6.1 Available tables and transmission repetition rates For each Table to be transmitted is possible to set the repetition rate accordingly to the ISDB-T standard. The repetition rate parameter is set in similar way for each PSI/SI table, in the following figure is shown an example for the PMT Table.
  • Page 163: Table 32. Available Tables List

    ISO 9001:2000 Cert. N°4500/1 Table 32. Available tables list Table Status Repetition rate Available 100 ms Available 10 s 100 ms (non one-seg service) Available 200 ms (one-seg service) 1…3 s (nominal 1 s) 0X10 Available 0X11 Available 1…3 s (nominal 2 s) 0X11 Available 0X12...
  • Page 164: Table 33. Bat Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 33. BAT parameters Table Parameter / Control Description Admitted Ranges / Values PID of the BAT table. This field is indicator only, and it must be set BAT PID always to 17 according to ABNT NBR 15603-2 standard. Table ID of the BAT table.
  • Page 165: Table 34. Bit Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 34. BIT parameters Table Parameter / Control Description Admitted Ranges / Values PID of the BIT table. This field is indicator only, and it must be set BIT PID always to 36 according to ITU 13818-1 standard Table ID of the BIT table.
  • Page 166 ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values BIT \ By performing the “Add” command on this node, a sub-window that Broadcasters \ Broadcaster xxx \ allows adding the list of descriptors associated with the Broadcaster Broadcaster opens.
  • Page 167: Table 35. Cat Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 35. CAT parameters Table Parameter / Control Description Admitted Ranges / Values PID of the CAT table. This field is indicator only, and it must be set CAT PID always to 1 according to ITU 13818-1 standard Table ID of the CAT table.
  • Page 168: Table 36. Cdt Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 36. CDT parameters Table Parameter / Control Description Admitted Ranges / Values PID of the CDT table. This field is indicator only, and it must be set CDT PID to 41 as indicated in the ARIB STD-B21 standard. Table ID of the CDT table.
  • Page 169: Table 37. Dit Parameters

    ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values This 8 bit field indicates the type of transmitted download data. 0x01 Data Type 0 - 255 is the logo data. This field denotes the download data by the syntax defined for each Data Module Bytes data_type.
  • Page 170: Table 38. Ert Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 38. ERT parameters Table Parameter / Control Description Admitted Ranges / Values PID of the ERT table. This field is indicator only, and it must be set ERT PID to 33 as indicated in the ABNT NBR 15603-3 standard. Table ID of the ERT table.
  • Page 171: Table 39. Ldt Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 39. LDT parameters Table Parameter / Control Description Admitted Ranges / Values PID of the LDT table. This field is indicator only, and it must be set LDT PID always to 19 according to ITU 13818-1 standard Table ID of the LDT table.
  • Page 172: Table 40. Lit Parameters

    ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values LDT \ By performing the “Add” command on this node, a sub-window that Descriptions \ allows adding the list of descriptors associated with a Description Description xxx \ opens.
  • Page 173 ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values 16 bits field that indicates the service_id number (a network exclusive identification) of the service for whom the event described Service ID by the local event information section which it belongs. The 0 - 65535 service_id shall be the same of the program_number in the corresponding program map section.
  • Page 174 ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values 16 bits field that indicate the node_id of a parent node when the node refers to another node in the event relation subtable as a Parent Node ID 0 -65535 parent in the tree structure.
  • Page 175: Table 41. Nbit Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 41. NBIT parameters Table Parameter / Control Description Admitted Ranges / Values PID of the NBIT table. This field is indicator only, and it must be set NBIT NBIT PID always to 19 according to ITU 13818-1 standard ...
  • Page 176: Table 42. Nit Parameters

    ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values This control allows setting the location of the table where contents Description Body of the information are described. NBIT \ Board Info Location Please select the desired information type from the menu. 0 –...
  • Page 177 ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values This control allows setting the unique value that identifies the 0 – 65535 Network ID network that is described in the table. This flag indicates that the table is still applicable. Uncheck this ...
  • Page 178: Table 43. Pat Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 43. PAT parameters Table Parameter / Control Description Admitted Ranges / Values PID of the PAT table. This field is indicator only, and it must be set PAT PID always to 0 according to ITU 13818-1 standard. Table ID of the PAT table.
  • Page 179: Table 44. Pcat Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 44. PCAT parameters Table Parameter / Control Description Admitted Ranges / Values PID of the PCAT table. This field is indicator only, and it must be set PCAT PCAT PID always to 34 according to ITU 13818-1 standard Table ID of the PCAT table.
  • Page 180 ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values PCAT \ Content Version of the partial content announced in the table, which 0 – 65535 Content Version Versions corresponds to the version of the full content. PCAT \ Content Content Minor 0 –...
  • Page 181: Table 45. Pmt Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 45. PMT parameters Table Parameter / Control Description Admitted Ranges / Values 0 – 8191, except for the PID reserved PID of the PMT table. This field must be set according to ITU PMT PID 13818-1 standard.
  • Page 182 ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values for value assignment. For more information refer to ABNT NBR 15603-2 standard, Annex J.  0: ITU-T | ISO/IEC reserved  1: ISO/IEC 11172-2 Video  2: ITU-T Rec. H.262 | ISO/IEC 13818-2 Video or ISO/IEC 11172-2 constrained parameter video stream ...
  • Page 183: Table 1. Rst Parameters

    ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values stream conveyed in ISO/IEC 14496.  20: ISO/IEC 13818-6 Download synchronization protocol.  21: Metadata transported by a PES packet.  22: Metadata transported by a metadata_section ...
  • Page 184: Table 46. Sdt Parameters

    ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values Table ID of the RST table. This field must be set always to 113 Table ID according to ITU 13818-1 standard. By performing the “Add” command on this node, a sub-window that RST \ Identifiers allows adding the list of Identifiers opens.
  • Page 185 ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values This control allows setting the Version Number of the SDT table, 0 – 31 Version number according to the ITU 13818-1 standard this value should be changed every time the table data are modified. This control allows setting the Original Network ID for the TS 0 –...
  • Page 186 ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values This control allows setting the running status of the service. SDT \ Service Running Status List Please select the desired running status from the menu. By performing the “Add” command on this node, a sub-window that SDT \ Service List \ Service xxx allows adding the list of descriptors associated with the Service...
  • Page 187: Table 47. Sdtt Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 47. SDTT parameters Table Parameter / Control Description Admitted Ranges / Values PID of the SDTT table. This field is indicator only, and it must be set to:  SDTT SDTT PID 0x0023 in the low protection layer (full-seg service) 35, 40 ...
  • Page 188 ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values SDTT Group 4 bits field that should contain the group_id value. 0-15 12 bits field that indicates the version number of the download SDTT Target Version 0-4095 content that will be used in the upgrade.
  • Page 189: Table 48. Sit Parameters

    ISO 9001:2000 Cert. N°4500/1 Table 48. SIT parameters Table Parameter / Control Description Admitted Ranges / Values PID of the SIT table. This field is indicator only, and it must be set SIT PID always to 31 according to ARIB STD B21 standard. Table ID of the SIT table.
  • Page 190: Table 49. St Parameters

    ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values This 3-bit field indicates the running status of the event in the original stream. This is the running status of the original present Running Status event. If no present event exists in the original stream, the status is considered as “not running”...
  • Page 191: Table 51. Tot Parameters

    ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values Section Syntax This is a one-bit indicator which shall be set to "0". Indicator (Current time and date): This 40-bit field contains the current time and date in Brazil (UTC-3) and MJD. This field is coded as 16-bit The current date may be indicated from UTC Time giving the 16 LSBs of MJB followed by 24 bits coded as 6 digits in a...
  • Page 192 ISO 9001:2000 Cert. N°4500/1 Table Parameter / Control Description Admitted Ranges / Values Table ID of the TSDT table. This field is indicator only, and it must TSDT Table Id be set always to 3 according to ISO/IEC 13818-1 standard. Section Syntax TSDT This 1-bit field may take either the value "1"...
  • Page 193: Available Descriptors

    ISO 9001:2000 Cert. N°4500/1 5.8.6.2 Available descriptors Here follows the list of the descriptors available and their usage for each SI/PSI table. The descriptors highlighted in gray are not available in the actual version of the XBT527-8. The points indicate in which tables the descriptors can be used. The points plus exclamation marks indicate in which tables the descriptors are mandatory.
  • Page 194: Table 53. Use Of Descriptors For Each Table

    ISO 9001:2000 Cert. N°4500/1 Table 53. Use of descriptors for each table Descriptors PMT NIT PCAT NBIT LDT SDTT LIT ERT LDT TSDT 0x00 Application descriptor 0x01 Application name descriptor 0x02 Transport protocol descriptor ● 0x02 Video stream descriptor 0x03 Ginga-j application descriptor ●...
  • Page 195 ISO 9001:2000 Cert. N°4500/1 Descriptors PMT NIT PCAT NBIT LDT SDTT LIT ERT LDT TSDT Ginga-NCL application 0x07 location descriptor ● Target background grid 0x07 descriptor 0x08 NCL-HTML descriptors 0X09 (reserved by MHP) 0X0A ● 0x08 Video window descriptor ● ●...
  • Page 196 ISO 9001:2000 Cert. N°4500/1 Descriptors PMT NIT PCAT NBIT LDT SDTT LIT ERT LDT TSDT ● Private data indicator 0x0F descriptor ● 0x10 Smoothing buffer descriptor 0x11 IP signalling descriptor ● 0x11 STD descriptor ● 0x12 IBP descriptor ● 0x13 Carousel ID descriptor ●...
  • Page 197 ISO 9001:2000 Cert. N°4500/1 Descriptors PMT NIT PCAT NBIT LDT SDTT LIT ERT LDT TSDT ● 0x22 Fmx buffer size descriptor ● 0x23 Multiplex buffer descriptor ● 0x24 Content labeling descriptor ● 0x25 Metadata pointer descriptor ● 0x26 Metadata descriptor 0x27 Metadata STD descriptor ●...
  • Page 198 ISO 9001:2000 Cert. N°4500/1 Descriptors PMT NIT PCAT NBIT LDT SDTT LIT ERT LDT TSDT ●! ●! ●! 0x41 Service list descriptor ● ● ● ● ● ● ● 0x42 Stuffing descriptor 0x45 VBI data ●! ● ● 0x47 Bouquet name descriptor ●! ●...
  • Page 199 ISO 9001:2000 Cert. N°4500/1 Descriptors PMT NIT PCAT NBIT LDT SDTT LIT ERT LDT TSDT ● ● ● ● 0x53 CA identifier descriptor ● ● 0x54 Content descriptor ● ●! ● 0x55 Parental rating descriptor ● 0x58 Local time offset descriptor Private data specifier 0x5F descriptor...
  • Page 200 ISO 9001:2000 Cert. N°4500/1 Descriptors PMT NIT PCAT NBIT LDT SDTT LIT ERT LDT TSDT ● Partial transport stream time 0xC3 descriptor ●!H ● 0xC4 Audio component descriptor ●!M ● ● 0xC5 Hyperlink descriptor Target region (area) ● 0xC6 descriptor ●...
  • Page 201 ISO 9001:2000 Cert. N°4500/1 Descriptors PMT NIT PCAT NBIT LDT SDTT LIT ERT LDT TSDT ● Short node information ● 0xD3 descriptor STC (system time clock) 0xD4 reference descriptor ● ● 0xD5 Series descriptor ● ● 0xD6 Event group descriptor ●...
  • Page 202 ISO 9001:2000 Cert. N°4500/1 Descriptors PMT NIT PCAT NBIT LDT SDTT LIT ERT LDT TSDT composite descriptor Conditional playback ● ● 0xF8 descriptor Terrestrial delivery system ●! 0xFA descriptor ● 0xFB Partial reception descriptor Emergency information ● ● 0xFC descriptor 0xFD Data coding descriptor ●...
  • Page 203: Descriptor Fields

    ISO 9001:2000 Cert. N°4500/1 5.8.6.3 Descriptor fields Here follows the explanation of all fields for each descriptor. Please note that no control is implemented for descriptors placement: user must be careful to place the descriptor in the appropriate table. Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 203 of 468...
  • Page 204: Table 54. Descriptors Fields

    ISO 9001:2000 Cert. N°4500/1 Table 54. Descriptors fields Descriptor Parameter / Control Description Admitted Ranges / Values Application 0x00 NOT YET IMPLEMENTED descriptor Application name 0x01 NOT YET IMPLEMENTED descriptor Transport protocol 0x02 NOT YET IMPLEMENTED descriptor  Only a single rate frame is present This field sets the presence or not of multiple rate multiple rate frame flag ...
  • Page 205 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Video stream contains only ISO/IEC 11172-2 data This field sets the video stream format, MPEG 1 only or  Video stream may contain both MPEG 1 only flag constrained parameters ISO/IEC 11172-2 video data and ITU-T H.262 | ISO/IEC 113818-2 video data...
  • Page 206 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Reserved  This flag is active only if MPEG1 only flag is not active,  Level indication and it is valid only when Escape flag is low. It sets level Main indication.
  • Page 207 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Audio frame with the bitrate index is set “0000” free format flag This flag sets the format of audio stream (free or not)  Audio frame with the bitrate index is not set “0000”...
  • Page 208 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  reserved  ITU-T Rec. H.262 | ISO/IEC 13818-2 Spatial Scalability  ITU-T Rec. H.262 | ISO/IEC 13818-2 SNR Scalability  ITU-T Rec. H.262 | ISO/IEC 13818-2 Temporal Scalability ...
  • Page 209 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values The hierarchy channel is a field that indicates the intended channel number for the associated program element in an ordered set of 0 – 63 hierarchy channel transmission channels.
  • Page 210 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Forbidden & DAR:Forbidden  1.0 (Square Simple)  DAR 3:4 aspect ratio information This field sets the aspect ratio information  DAR 9:16  DAR 1:2.21 ...
  • Page 211 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field sets the language code with 3 characters 3 ASCII characters ISO 639 language code identifying the nation, according with ISO 639 standard.  Undefined  Clean effect ISO 639 language 0x0A...
  • Page 212 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  LTW offset lower & upper bounds valid This flag indicates if LTW offset lower and upper Bound valid flag bounds are valid or not  LTW offset lower & upper bounds not valid Multiplex buffer utilization...
  • Page 213 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  The transfer of data from the buffer MBn to the buffer EBn uses the vbv delay method STD descriptor 0x11 Leak valid flag This flag sets the transfer data method used. ...
  • Page 214 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field is enable only if Format ID is FormatSpecifier ModuleId 0 - 65535 This field specifies the ModuleId This field is enable only if Format ID is FormatSpecifier BlockSize 0 - 65535 This field specifies the BlockSize...
  • Page 215 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field is enable only if use is 0 This field specifies the DownloadServerInitiate() 0 – 4294967295 transaction_id message When DownloadServerInitiate() message is allowed to change transaction_id must be 4294967295 This field is enable only if use is 0 This field specifies the DownloadServerInitiate() message acquisition message time out in...
  • Page 216 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Simple Profile/Level 1, 2, 3, 0  Simple Scalable Profile/Level 0, 1, 2  Core Profile/Level 1, 2  Main Profile/Level 2, 3, 4  N-bit Profile/Level 2 ...
  • Page 217 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Main profile, level 1, 2, 3, 4  Scalable Profile, level 1, 2, 3, 4  Speech profile, level 1, 2  Synthesis profile, level 1, 2, 3 ...
  • Page 218 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field shall specify the identifier of an ISO/IEC 14496-1 SL-packetized stream. There can be any 0 – 65535 ES ID number of couples ES ID / FlexMuxchannel. To add a new couple, click on add button.
  • Page 219 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  0 – 15 Reserved  16 ISO 15706 (ISAN) encoded in its binary form This field specifies the application responsible for  17 ISO 15706-2 (V-ISAN) encoded in defining usage its binary form metadata application format...
  • Page 220 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  0 No content time base defined in This field specifies the used content time base this descriptor If this field is Use of STC content time base value and ...
  • Page 221 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  0 – 15 Reserved  16 ISO 15706 (ISAN) encoded in its binary form This field specifies the application responsible for  17 ISO 15706-2 (V-ISAN) encoded in defining usage its binary form metadata application format...
  • Page 222 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field is editable only If metadata format is Defined by metadata_format_identifier metadata format identifier 0 - 4294967295 This field specifies the value obtained from a Registration Authority as designated by ISO/IEC JTC 1/SC 29 This field specifies the metadata service in the 0 –...
  • Page 223 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field specifies the program number of the program number 0 - 65535 association metadata service This field specifies the transport stream location of the transport stream location 0 - 65535 association metadata service This field specifies the transport stream id of the...
  • Page 224 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  0 – 15 Reserved  16 ISO/IEC 15938-1 TeM  17 ISO/IEC 15938-1 BiM This field specifies the metadata format and coding  18 – 62 Reserved metadata format If This field is Defined by metadata_format_identifier, ...
  • Page 225 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  0 No decoder configuration is needed.  1 The decoder configuration is carried in this descriptor in the decoder_config_byte field.  2 The decoder configuration is carried in the same metadata service This field specifies whether and how decoder as to which this metadata descriptor...
  • Page 226 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field is editable only If decoder config flags is 4 0 – 255 decoder config metadata service id This field specifies the metadata service that contains the decoder configuration This field is editable only If decoder config flags is 5 - 6 reserved...
  • Page 227 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Bitstream obeys all constraints specified in H264 subclause A.2.1 This flag indicates if bitstream obeys all constraints constraint set0 flag  Bitstream may not obey all specified in H264 subclause A.2.1 or not constraints specified in H264 subclause A.2.1...
  • Page 228 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  The SEI buffering period shall be according to ITU Recommendation H264 annex C hrd management valid flag This flag sets the SEI buffering period  The alternative method defined in ITU Recommendation H.222.0 and ISO/IEC 13818-1 ...
  • Page 229 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  The information about relation between POC information of video stream and the time shall not be This flag indicates if AVC video stream transmits temporal poc flag transmitted temporal picture order information, or if it may not do it.
  • Page 230 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  This field specifies the configuration and the number of 1 single channel element: center the audio channel front speaker  2 channel pair element: left, right front speakers ...
  • Page 231 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values FCR ES ID This field specifies the ES ID associated 0 - 65535 FCRResolution This field specifies the resolution of the object 0 - 4294967295 FlexMuxTiming 0x2C This field specifies the length of the fmxClockReference descriptor FCRLength...
  • Page 232 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values To add a data service ID, right click on services and select add in pop-up menu. To change data service ID, double-click on service ID to edit it. To delete a data service ID, right click on it and select remove in pop-up 0 –...
  • Page 233 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values To add field, right click on a data service ID and select add in pop-up menu. Reserved field is editable only if data service ID value is not between 1 and 7. To edit field, select correspondent reserved field.
  • Page 234 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This is a field which uniquely identifies an information 0 – 65535 service id service within a TS.  reserved for future use  information service  EPG service ...
  • Page 235 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values There can be any number of each field. To add fields, click on add button. To remove them, select them and 0 – 65535 service id click on remove button. This field identifies the service ID.
  • Page 236 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values String containing item name. There can be any number of couples item description char – item char. To add a item char Any string of ASCII characters couple, push add button.
  • Page 237 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values To add a logical cell id, right click on service and select add in pop-up menu. To edit a logical cell id, double click on logical cell id field. To remove it, right click on it and select remove in pop-up menu.
  • Page 238 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Undefined Field refers to a logical cell id, and provides for that cell the linkage info. To edit it, select correspondent logical  Bouquet related cell id. ...
  • Page 239 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values There can be any number of couples content – user nibble. To add one, push add button. To remove it, Content nibble Refer to table 28 in ETSI EN 300 468 select it and push remove button.
  • Page 240 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Reserved All fields can be in any number. To add fields, push add  button. To remove them, select them and push remove button.  This field specifies the minimum advised age of end ...
  • Page 241 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values All fields can be in any number. To add fields, push add button. To remove them, select them and push remove button. 0 – 12 : 0 – 59 local time offset This field specifies local time offset respect to respect to Brasilian official time, i.e UTC-3.
  • Page 242 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field sets the maximum smoothing buffer size for 0 – 16383 Maximum overall smoothing buffer the overall TS. It is expressed in bytes. This 16-bit field identifies the data broadcast 0 –...
  • Page 243 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Main Audio Profile L1, L2, L3, L4  Scalable Audio Profile L1, L2, L3, L4  Speech Audio Profile L1, L2  Synthetic Audio Profile L1, L2, L3 ...
  • Page 244 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  quality level This flag sets the quality (high or low). Hierarchical  transmission 0xC0 descriptor 0 – 8191 reference PID This is the PID of elementary stream. ...
  • Page 245 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field is editable only if component control flag is high. It identifies component which digital copy control 0 – 255 component tag is referred to. There can be any number of component tags.
  • Page 246 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values stream time 40-bit field that shall contain the start time of the event descriptor in the UTC -3 and the date in “modified julian date” The date may be indicated from March 1st, (MJD).
  • Page 247 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values descriptor component tag field shall be a label to identify the component stream 0 - 255 stream type field shall indicate the audio stream type 0 - 255 field shall provide the same number to the operating simulcast group tag simulcast component...
  • Page 248 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field sets the language code with 3 characters ISO 639 language code 3 ASCII characters identifying the nation, according with ISO 639 standard. This field sets the language code with 3 characters identifying the nation, according with ISO 639 standard.
  • Page 249 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  reserved  link to service  link to event The field specifies the linkage destination type. Some  of following fields are editable, according to the link link to module destination type value.
  • Page 250 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values field shall describe the identification number of the 0 – 65535 module Id linked carousel module field shall describe the identification number of the 0 – 4294967295 content id content uniformly linked to the service field shall provide of information provided by identifier...
  • Page 251 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values Field shall describe the component tag of content in the component ref Any hexadecimal number event This field sets the language code with 3 characters ISO 639 language code 3 ASCII characters identifying the nation, according with ISO 639 standard.
  • Page 252 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values Flag indicating whether an overwrite of an existing  module or addition occurs. “Set” indicates addition, “Not Add on  Set” indicates continuous overwrite. Not Set Flag indicating the presence/absence of a ...
  • Page 253 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field contains a component tag of a corresponding Component tag stream that is given by a stream identification 0 - 255 descriptor in PMT. Set ‘compatibility flag’ to “Set”. Right click on ‘CompatibilityDescriptor’...
  • Page 254 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values Set ‘compatibility flag’ to “Set”. Set ‘module info flag’ to “Set”. Click on the Add button just appeared: double click on Module ID Module ID field to set the module id. 0 - 65535 Module ID: identification of a module in the carousel to download contents.
  • Page 255 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values Set ‘text info flag’ to “Set” and text char field will appear. Text char Text char: description concerning the service of the download content to be transmitted. Private data byte Byte array used for private data.
  • Page 256 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Not accepted  Digital terrestrial television broadcast This field sets broadcaster type. Its value determines broadcaster type which of following fields shall be editable.  Reserved for future use ...
  • Page 257 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field is editable only if broadcaster type is reserved 0 – 65535 terrestrial sound broadcaster id for future use. It sets the terrestrial sound broadcaster This field is editable only if broadcaster type is reserved for future use.
  • Page 258 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field is private. It is editable only if logo Private data bytes Any hexadecimal value transmission type is reserved for future use.  Invalid   Relative time ...
  • Page 259 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field is editable only if segmentation mode is one Hour: 0 – 99 of these: Relative time, Relative time (STC reference Minutes: 0 – 59 Duration descriptor is used together), UTC-3 time, UTC-3 time (STC reference descriptor is used together).
  • Page 260 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values There can be any number of reference node id, reference number and last reference number fields. To add one of them, click add button. To remove it, click remove button.
  • Page 261 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values 0 – 65535 Reference node id This field sets reference node identification. This field sets reference priority to the node to be 0 – 255 Reference number referred to.
  • Page 262 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Invalid  Field that designates the reference type of the time in  the STC reference descriptor. Generally, the mode Undefined STC reference mode corresponding to the segmentation mode of the basic ...
  • Page 263 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field shall give the label identifying the broadcasting series, informing its duration and its 0 – 15 repeat label repetition. Original series broadcasting shall be given with "0".
  • Page 264 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field shall indicate the total number of episodes of the series. It can be indicated from 1 to 4 095. When 0 – 4095 last episode number the episode number exceeds this value, it shall be set separately.
  • Page 265 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values There can be any number of 4 fields original network id – transport stream id - service id – event id. These are editable only if group type is Event relay to other networks or Event movement from other networks.
  • Page 266 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values There can be any number of 4 fields original network id – transport stream id - service id – event id. These are editable only if group type is Event relay to other networks or Event movement from other networks.
  • Page 267 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  This field indicates the component group type. Multiview service component group type  Refer to Table 78 in ABNT NBR 15603-2 Undefined This flag shall indicate the description status of the total ...
  • Page 268 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values Each CA unit id can have up to 31 component tags. To add one, right click on CA unit id and select add in pop- up menu. To edit it, right click and select edit in pop-up menu on it.
  • Page 269 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values There can be any number of couples table id – table description byte. To add one, push add button. To remove it, select it and push remove button. 0 –...
  • Page 270 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Undefined  Described with short_event_descriptor  Described with extended_event_descriptor There can be any number of fields description id – description type – user defined. To add one, click on ...
  • Page 271 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Differential modulation  Synchronous modulation modulation type A This field sets modulation type A.  Reserved for future use  Refer to TMCC signal  Differential modulation ...
  • Page 272 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  1 hour and half  3 hours  6 hours  12 hours retention state This field sets allowed time of temporal accumulation.  1 day ...
  • Page 273 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values 0 – 65535 This field is editable only if Service group type is equal to 0x01 Primary service identifier This field identify the primary service 0 – 65535 This field is editable only if Service group type is equal to 0x01 Secondary service identifier...
  • Page 274 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Ceará  Rio Grande do Norte  Paraíba  Pernambuco  Sergipe  Alagoas  Bahia  Minas Gerais  Espírito Santo  Rio de Janeiro ...
  • Page 275 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  1/32  1/16 Guard interval This field sets guard interval used in transmission.    Mode 1  Mode 2 Transmission mode This field sets transmission mode used. ...
  • Page 276 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values This field refers to a service id. To edit it, select a  start end flag service id. If this flag is 1, emergency signal has  started.
  • Page 277 ISO 9001:2000 Cert. N°4500/1 Descriptor Parameter / Control Description Admitted Ranges / Values  Undefined  Not used  broadcasting identifier This field sets broadcasting type. ISDB system  Not used  Undefined 0 – 255 additional broadcasting identification This field is broadcaster-defined. Additional info This field is user defined.
  • Page 278: Hyperlink Descriptor

    ISO 9001:2000 Cert. N°4500/1 5.8.6.4 Hyperlink descriptor The following table shows all editable fields for the correspondent values of link destination type in hyperlink descriptor. Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 278 of 468...
  • Page 279: Table 55. Hyperlink Editable Fields

    ISO 9001:2000 Cert. N°4500/1 Table 55. Hyperlink editable fields Link Link to Link to Link to Link to Link to Link to Link to ert User Fields destination content stored Reserved service event module content node defined type value module content •...
  • Page 280: Service Type

    ISO 9001:2000 Cert. N°4500/1 5.8.6.5 Service type Here are listed all possible values for service type field, which is located in service list descriptor or in service descriptor: Table 56. Service type possible values Reserved for future use Advanced coding for digital NVOD HD television service Advanced coding for digital NVOD HD time-shifted Digital television service television service...
  • Page 281: Characters Coding

    ISO 9001:2000 Cert. N°4500/1 5.8.6.6 Characters coding This paragraph explains the characters coding implemented for PSI compiling (according to ARIB_STD- B24—1_v5.1_E1 and ABNTNBR15606-1). Hereafter the table for the Latin characters coding; each character is codified by a specific hexadecimal value (1 byte). The XBT527-8 Java software decodes automatically the latin characters inserted by user into the right hexadecimal values.
  • Page 282: Table 58. G3 Special Characters Coding

    ISO 9001:2000 Cert. N°4500/1 The XBT527-8 java software inserts automatically the SS3 control character (0x1D) before each G3 special character. The user can insert a special character writing the specific hexadecimal value between quotation marks (e.g. write “x4B” to insert the special character ⅞; the java will write 0x1D4B). Table 58.
  • Page 283 ISO 9001:2000 Cert. N°4500/1 Cl oonkol code Function Description Active position up Moves to the previous line along line direction in the length of line direction of the character field. When the reference point of the character field exceeds the edge of display area by this movement, move to the last line of the display area along the line direction.
  • Page 284: Table 1. C1 Control Set C0 Control Set

    ISO 9001:2000 Cert. N°4500/1 Table 1. C1 control set C0 control set Cl oonkol code Function Description Black Foreground colour: black ,CMLA: 0 Foreground (This indicates that foreground colour is set to black and colour map lower address (CMLA) specifying colouring value of the portrayal plane is set to 0.
  • Page 285 ISO 9001:2000 Cert. N°4500/1 Cl oonkol code Function Description Colour Controls Colour Controls Colour control COL P1 (1 byte) Sets foreground colour, background colour, half foreground colour, half background colour and CMLA by the parameter. Colour between foreground and background in gradation font is defined that colour near to foreground colour is half foreground colour and colour near to background colour is half background colour.
  • Page 286 ISO 9001:2000 Cert. N°4500/1 Cl oonkol code Function Description COL 06/0: half foreground colour – black ,CMLA 0 COL 06/1: half foreground colour - full intensity red ,CMLA 1 COL 06/2: half foreground colour - full intensity green ,CMLA 2 COL 06/3: half foreground colour - full intensity yellow ,CMLA 3 COL 06/4: half foreground colour - full intensity blue...
  • Page 287 ISO 9001:2000 Cert. N°4500/1 Cl oonkol code Function Description Palette control COL P1 (1 byte) P2 (1 byte) Specifies palette number by parameter COL 02/0 04/0 : Palette number 0 COL 02/0 04/1 : Palette number 1 COL 02/0 04/2 : Palette number 2 COL 02/0 04/3 : Palette number 3...
  • Page 288 ISO 9001:2000 Cert. N°4500/1 Cl oonkol code Function Description Character Size The character size is set in parameter P1 (1 byte). Controls SZX 06/0: Tiny size SZX 04/1: Double height SZX 04/4: Double width SZX 04/5: Double height and width SZX 06/11: Special 1 SZX 06/4: Special 2 Flashing control...
  • Page 289 ISO 9001:2000 Cert. N°4500/1 Cl oonkol code Function Description Writing Mode This Specifies the changing of the writing mode to the memory of display Modification by parameter P1 (1 byte). For middle colour of gradation font, both set portions of half foreground colour and half background colours are to be treated as foreground colour.
  • Page 290 ISO 9001:2000 Cert. N°4500/1 Cl oonkol code Function Description I MACRO I 04/0 I MC I Macro body MACRO I 04/15 Repeat The repeat code RPC with one parameter P1 (1 byte) causes a Character displayable character or mosaic that immediately follows the code, to be displayed a number of times specified by the parameter Pl.
  • Page 291 ISO 9001:2000 Cert. N°4500/1 Cl oonkol code Function Description HIGHLIGHTI Starting and ending of enclosure are set by parameter P1 (1 byte). HLC 04/0 : Enclosure ends CHARACTER HLC 04/1 : Enclosure 1 starts BLOCK HLC 04/2 : Enclosure 2 starts HLC 04/3 : Enclosure 3 starts HLC 04/4...
  • Page 292: Isdb-T Measure

    ISO 9001:2000 Cert. N°4500/1 5.8.7 ISDB-T Measure Click on Measure button, highlighted in the next figure, to access the measure window. Figure 54. ISDBT-Processing: ISDBT - Measure Use the Measure window to monitor output signal level and quality. Refer to ISDB-T FE Type paragraph for a detailed description of the status and demodulation parameters of the ISDB-T Measure window.
  • Page 293: Isdb-T Measure Window: Rf Power Level Monitor

    ISO 9001:2000 Cert. N°4500/1 5.8.7.1 ISDB-T Measure window: RF power level monitor Figure 55. ISDB-T Measure: RF power level monitor Table 1. ISDB-T Measure: RF power level monitor Parameter / Control Description Admitted Ranges / Values This value is the level of the signal, passing through the Monitor Tx Level ...
  • Page 294: Atsc

    ISO 9001:2000 Cert. N°4500/1 5.9 ATSC Click on ATSC button, highlighted in the next figure, to access the ATSC window. Figure 56. ATSC window Use the ATSC Processing page to manage ATSC specific configuration parameters and to monitor output signal level and quality. Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 294 of 468...
  • Page 295: Atsc Settings

    ISO 9001:2000 Cert. N°4500/1 5.9.1 ATSC Settings Click on the ATSC Settings button, highlighted in the next figure, to access the ATSC general settings. Figure 57. ATSC Processing: ATSC Settings Use the ATSC Settings page to select inputs, to set input/output RF channels, offset frequencies, Frontend and Measure alarm thresholds and to manage Input Autoswitch functionality (refer to Appendix A for further information).
  • Page 296: Table 2. Atsc Processing: Atsc Settings

    ISO 9001:2000 Cert. N°4500/1 Table 2. ATSC Processing: ATSC Settings Parameter / Control Description Admitted Ranges / Values  ASI 1  ASI 2 Input selector.  ASI 3 It is not allowed to change input until the Input Autoswitch is ...
  • Page 297 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min: 0 s Primary to Secondary Primary to secondary input switch countdown expressed in  Input Autoswitch Max: *.def file dependant Switch Counter seconds.  Default: 25 s ...
  • Page 298 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min: 10 MEAS Alarm SNR Thr [dB] Meas Signal to Noise alarm threshold. Thresholds  Max: 50 Channel ranges are device’s definition Output Channel Output channel. dependant. ...
  • Page 299: Atsc Modulation

    ISO 9001:2000 Cert. N°4500/1 5.9.2 ATSC Modulation The ATSC Modulation window allows to select test signals and to manage the M/H mode. Figure 58. ATSC Processing: ATSC Modulation Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 299 of 468...
  • Page 300: Table 3. Atsc Processing: Atsc Modulation

    ISO 9001:2000 Cert. N°4500/1 Table 3. ATSC Processing: ATSC Modulation Parameter / Control Description Admitted Ranges / Values  Checked: Enabled MODULATION Delete Null Packets Delete null packets enabling check box.  Not checked: Disabled  None  TEST The selector of test signal. ...
  • Page 301: Atsc Tvct

    ISO 9001:2000 Cert. N°4500/1 5.9.3 ATSC TVCT The ATSC TVCT window allows to modify On-The-Fly Major and Minor channel numbers associated with the virtual channels defined in the incoming TVCT. If the definition of the current TVCT changes, the version number of the table shall be accordingly modified otherwise the functioning of the facility is not assured.
  • Page 302: Atsc Measure

    ISO 9001:2000 Cert. N°4500/1 5.9.4 ATSC Measure Click on Measure button, highlighted in the next figure, to access the measure window. Figure 61. ATSC Processing: ATSC Measure Use the Measure window to monitor output signal level and quality. Refer to ATSC FE Type paragraph for a detailed description of each field within this window.
  • Page 303: Atsc Measure Window: Rf Power Level Monitor

    ISO 9001:2000 Cert. N°4500/1 5.9.4.1 ATSC Measure window: RF power level monitor Figure 62. ATSC Measure: RF power level monitor Table 4. ATSC Measure: RF power level monitor Parameter / Control Description Admitted Ranges / Values This value is the level of the signal, passing through the Monitor Tx Level ...
  • Page 304: Itu.470

    ISO 9001:2000 Cert. N°4500/1 5.10 ITU.470 Click on ITU button, highlighted in the next figure, to access the ITU modulator parameters window. Figure 63. ITU window Use the ITU Processing page to manage the configuration of the analog modulator. Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 304 of 468...
  • Page 305: Itu Settings

    ISO 9001:2000 Cert. N°4500/1 5.10.1 ITU Settings Click on the ITU Settings button, highlighted in the next figure, to access the ITU general settings. Figure 64. ITU Processing: ITU Settings Use the ITU Settings page to select inputs, to set input/output RF channels, offset frequencies, Frontend and Measure alarm thresholds and to manage Input Autoswitch functionality (refer to Appendix A for further information).
  • Page 306: Table 5. Itu Processing: Itu Settings

    ISO 9001:2000 Cert. N°4500/1 Table 5. ITU Processing: ITU Settings Parameter / Control Description Admitted Ranges / Values  SDI 1 Video input selector.  SDI 2 Use this control to select one of the available video inputs. CVBS analog inputs are available only when the A/V frontend is available. ...
  • Page 307 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min and Max values depends on the Output power setting. power class of the device. e.g. for a Output Power [w] SDTX-500 device: This control sets the output power in W. Changing this control will also change the value of power control expressed in dBm.
  • Page 308 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Priority Input Locked  Priority Input Not Locked Input Autoswitch State Current state of the finite-state machine  Searching First Input Locked  Check Priority Input Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 308 of 468...
  • Page 309: Itu Modulation

    ISO 9001:2000 Cert. N°4500/1 5.10.2 ITU Modulation The ITU Modulation window allows actual modulation parameters monitoring and setting. Figure 65. ITU Processing page: ITU Modulation The ITU Modulation window is composed by the following sections:  Modulator manager;  Test: used to manage RF test modes and Audio-Video test Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 309 of 468...
  • Page 310: Itu Modulation: Modulator Manager

    ISO 9001:2000 Cert. N°4500/1 5.10.2.1 ITU Modulation: Modulator manager Commands and indicators belonging to this section allow to:  Select the video modulation parameters;  Set the audio modulation parameters;  Set the group delay. Figure 66. ITU Modulation: Modulator manager Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 310 of 468...
  • Page 311: Table 6. Itu Modulation: Modulator Manager

    ISO 9001:2000 Cert. N°4500/1 Table 6. ITU Modulation: Modulator manager Parameter / Control Description Admitted Ranges / Values  MIN: 10 Video white level setting. The level value is in percentage upon the  White Level [%] Video MAX: 22 synch level.
  • Page 312 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values Audio 2 carrier level setting.  MIN: -22  Audio Carrier Level 2 [dB] MAX: -7 This parameter is the amplitude difference, expressed in dB values,  between the video carrier and the audio 1 carrier. Not used for Step: 1 mono audio carrier configurations such as NTSC or PAL M.
  • Page 313: Itu Modulation: Modulator Test Controls

    ISO 9001:2000 Cert. N°4500/1 5.10.2.2 ITU Modulation: Modulator test controls The following controls enable the testing of RF signal, audio and video. Figure 67. ITU Modulation: Modulator test modes Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 313 of 468...
  • Page 314: Table 7. Itu Modulation: Modulator Test Modes

    ISO 9001:2000 Cert. N°4500/1 Table 7. ITU Modulation: Modulator test modes Parameter / Control Description Admitted Ranges / Values  None;  CW: non modulated carrier at Test Test mode Enables one of the available test modes for RF signal. centre frequency;...
  • Page 315 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min: 7 Select the line where to inject the ITS 0 when the enable ITS insert Test ITS 0 option is enabled.  Max: 622  Min: 7 Select the line where to inject the ITS 1 when the enable ITS insert Test ITS 1...
  • Page 316: Manual Compensation

    ISO 9001:2000 Cert. N°4500/1 5.11 Manual compensation 5.11.1 Linear Precorrection Click on Linear Precorrection button, highlighted in the next figure, to access the filter window. Figure 68. Adaptive Linear Precorrection The ARK6 system provides a pre-correction tool for Module&Phase output signal pre-correction. This tool provides two grids for the drawing of: ...
  • Page 317 ISO 9001:2000 Cert. N°4500/1 In the module grid, the red curve is used to monitor the current module curve calculating and saving. The last saved coefficients are locally downloaded from the FPGA runtime memory registers in order to redraw the curve. Remember to click on the Save as button the first time you change the factory default curves in order to do not overwrite them.
  • Page 318: Non Linear Precorrection

    ISO 9001:2000 Cert. N°4500/1 5.11.2 Non Linear Precorrection Click on AM/PM button icon, highlighted in the next figure, to access the pre-correction window. Figure 69. AM/PM Precorrection Two main actions are possible in this section:  AM/AM and AM/PM curve drawing: used to change the AM/PM pre-correction coefficient. ...
  • Page 319: Port 5000 Connection

    ISO 9001:2000 Cert. N°4500/1 During saving actions one linear pre-correction file is created, the *.dpre file, which contains the digital coefficients for linear pre-correction filter. The following buttons allow the management of non linear pre-correction files and the management of the connection to port 5000: ...
  • Page 320: Adaptive Compensation

    ISO 9001:2000 Cert. N°4500/1 5.12 Adaptive compensation 5.12.1 Linear Adaptive Precorrection Click on Linear Adaptive Precorrection button, highlighted in the next figure, to access the filter window. Figure 71. Adaptive Linear Precorrection This window provides commands and indicators for adaptive filter management and monitor. The Filter window is organized as follows: ...
  • Page 321: Adaptive Filter

    ISO 9001:2000 Cert. N°4500/1 5.12.1.1 Adaptive Filter The Adaptive Filter provides the ARK6 with an effective adaptive linear compensation. The developed system is responsible for pre-emptively compensating the signal in order to make unimportant the contribution of the system transmission section. The signal passes through the transmission section and re-enters the system as to determine the distortion and the compensating adaptive filter.
  • Page 322: Adaptive Linear Precorrection: Management Panel

    ISO 9001:2000 Cert. N°4500/1 5.12.1.2 Adaptive Linear Precorrection: Management panel Table 8. Adaptive Linear Precorrection: Management panel Parameter / Control Description Admitted Ranges / Values General Load Loads filter coefficients from the respective FPGA registers. General Clear Loads flat curve coefficients. Once enabled, the adaptive linear compensation has a timeout.
  • Page 323: Complex Filter Coefficients Graph

    ISO 9001:2000 Cert. N°4500/1 5.12.1.3 Complex Filter coefficients graph The Complex Filter coefficients graph shows the current coefficients values. The circles indicate the real part of coefficients; the red crosses indicate the imaginary one. Figure 73. Filter window: complex filter coefficients graph 5.12.1.4 Module graph The Module graph shows the actual output signal module according to the complex filer coefficients applied.
  • Page 324: Adaptive Non-Linear Precorrection

    ISO 9001:2000 Cert. N°4500/1 5.12.2 Adaptive Non-Linear Precorrection The Non Linear Adaptive Filter provides the ARK6 with an effective adaptive non linear compensation. The developed system is responsible for pre-emptively compensating the signal in order to make unimportant the contribution of the intermodulation products due to the power amplifiers. The signal passes through the power amplifiers and re-enters the system as to determine the distortion and the compensating adaptive filter.
  • Page 325: Adaptive Non Linear Precorrection: Management Panel

    ISO 9001:2000 Cert. N°4500/1 5.12.2.1 Adaptive Non Linear Precorrection: Management panel Table 9. Adaptive Non Linear Precorrection: Management panel Parameter / Control Description Admitted Ranges / Values General Clear Resets the filter coefficients to zero.  ON(Green):Enabled General ON/OFF Enables the adaptive non linear compensation. ...
  • Page 326: Output

    ISO 9001:2000 Cert. N°4500/1 5.13 Output Click on Output button, highlighted in the next figure, to access the output window. Figure 77. Output window Use the Output window to change Ethernet, RF and ASI outputs settings, and to monitor all available hardware indicators.
  • Page 327: Table 10. Output Window

    ISO 9001:2000 Cert. N°4500/1 Table 10. Output window Parameter / Control Description Admitted Ranges / Values Output RF signal enabling. The possible output RF signal status are the following:  Green: ON   General RF ON / OFF Green: RF OFF ...
  • Page 328 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min: 24V First PSU voltage indicator, expressed in Volt, for SDTx20, Status PS 26V [V] SDTx50, SDTx201 and SDTx501 devices.  Max: 28V First PSU current indicator, expressed in Ampere, for SDTx20, ...
  • Page 329 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  6. Alarm OFF: an alarm switched off the amplifier Loading New Config 7. RF OFF: amplifier manually set to off  Reflex Pwr High Retry 8. Opto OFF: output RF is switched off by an optocoupler 9.
  • Page 330 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values Fan 2 speed indicator (values are expressed in rpm). Status Fan 2 Used in SDTx20, SDTx50, SDTx201 and SDTx501. Fan 3 speed indicator (values are expressed in rpm). Status Fan 3 Used in SDTx20, SDTx50, SDTx201 and SDTx501.
  • Page 331 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Green: Alarm on/Mode A/RF Off Relay 0…3 Opto & Relay Relays status indicators.  Grey: Alarm off/Mode B/RF On RF Off Opto status indicators. Opto 0 is a output RF manual on/off switch: ...
  • Page 332 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min: -200 kHz General Offset [Hz] Output frequency offset (expressed in Hz).  Max: +200 kHz Output power ranges are device’s General Power [dBm] Output power (expressed in dBm). definition dependant.
  • Page 333 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  ASI 1  ASI 2  ASI 3 It selects which TS input shall be re-transmitted on RTP output  channel 1. ASI 4 GbE 2 ch1/2 Tx Input ...
  • Page 334 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Digital: ASI 1 ASI 2 ASI 3 Digital modes: ASI 4 Selects which Transport Stream shall be re-proposed on ASI OUT HP/LP output. Tuner 1 (if present) Tuner 2 (if present) Analog modes: ASI Out 1/2...
  • Page 335: Reflex Power Management

    ISO 9001:2000 Cert. N°4500/1 5.13.1 Reflex Power Management The ARK6 is provided with a reflex power control logic that prevents the amplifier stage from being permanently damaged. Figure 78. Reflex Pwr Management If the output reflex power goes over its alarm threshold, the amplifier stage is automatically shut down and the system reacts to this situation on the basis of the user selectable “Number of attempts”.
  • Page 336: Table 11. Output Window: Reflex Pwr Management

    ISO 9001:2000 Cert. N°4500/1 Table 11. Output window: Reflex Pwr Management Parameter / Control Description Admitted Ranges / Values  Min: 0 Reflex Pwr The number of attempts to restore the system after RFL power has Number of attempts Management gone over the alarm threshold.
  • Page 337: Network

    ISO 9001:2000 Cert. N°4500/1 5.14 Network Click on Network button, highlighted in the next figure, to access the Network management window. Figure 79. Network window This window allows the Network management on both PRO-MPEG COP 3 RX and TX sides. It also allows the monitoring of the board IP and MAC addresses.
  • Page 338: Table 12. Network Window

    ISO 9001:2000 Cert. N°4500/1 Table 12. Network window Parameter / Control Description Admitted Ranges / Values GbE 1/2 General Settings / IP address Gbe port 1 / 2 IP address. Network GbE 1/2 General Settings / MAC address Gbe port 1 / 2 MAC address. Network GbE 1/2 General Settings /...
  • Page 339 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  UDP/RTP: GbE 2 ch1/2 Rx Protocol Ethernet input packets protocol. Green: Detected Grey: Not detected GbE 2 ch1/2 Rx Bitrate Bit-rate of TS from Ethernet input.  Zero when the input is not selected ...
  • Page 340 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values GbE 1 / 2 Statistic GbE Bad Pck The number of inbound packets that contained errors. Community Read community setting. Community Set community setting. Community Trap Trap community setting. ...
  • Page 341 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min: 1 GbE 2 ch1/2 Tx TS Pck per Frame Number of packets per frame.  Max: 7  GbE 2 ch1/2 Tx Frame type Transmission protocol selector. ...
  • Page 342: Gps

    ISO 9001:2000 Cert. N°4500/1 5.15 GPS Click on GPS button, highlighted in the next figure, to access the GPS received statistics window. Figure 80. GPS window Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 342 of 468...
  • Page 343: Table 13. Gps Window

    ISO 9001:2000 Cert. N°4500/1 Table 13. GPS window Parameter / Control Description Admitted Ranges / Values GPS Software General The firmware version of the GPS module. Version #Number of Visible Satellite Number of visible GPS satellites indicator. #Number of Tracked Satellite Number of tracked GPS satellites indicator.
  • Page 344: Holdover Management

    ISO 9001:2000 Cert. N°4500/1 5.15.1 Holdover Management The ARK6 includes a holdover function provided by a higher grade Oven-Controlled Crystal Oscillator. Figure 81. Holdover Management The ARK6 is equipped with an internal OCXO for improved phase noise and stability. The system is provided with internal 10MHz and 1PPS signals which are disciplined to the GPS time signal or to the 10MHz and 1PPS external references.
  • Page 345 ISO 9001:2000 Cert. N°4500/1 4. Holdover ON  Condition: if the OCXO is no more locked to the selected frequency reference and the Holdover function is enabled and available, the equipment enters into holdover mode.  Associated event: “Holdover ON”. 5.
  • Page 346: Table 14. Gps Window: Holdover Management

    ISO 9001:2000 Cert. N°4500/1 Table 14. GPS window: Holdover Management Parameter / Control Description Admitted Ranges / Values Internal frequency reference fine tuning setting. It is possible to increase and decrease the frequency offset of the OCXO with  Min: 0 Fine Frequency General reference to the 10MHz clock by 1/21 Hz steps using the Fine...
  • Page 347 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Green: Locked OCXO GPS Lock OCXO locked to the external GPS reference.  Grey: Not Locked  Green: Locked It shows whenever the OCXO is not locked to the selected OCXO Tracking frequency reference or not.
  • Page 348 ISO 9001:2000 Cert. N°4500/1 Parameter / Control Description Admitted Ranges / Values  Min:00:00:00 Holdover Timeout Status The countdown of the Holdover timeout. Management  Max: “Holdover Timeout [s]” Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 348 of 468...
  • Page 349: Alarms

    ISO 9001:2000 Cert. N°4500/1 5.16 Alarms Click on Alarms button, highlighted in the next figure, to access the alarms management window. Figure 82. Alarms window The Alarms window allows the setting of alarm masks and the monitoring of alarms status. Use alarm masks to select how and which alarm has to be notified.
  • Page 350: Table 15. Alarms Window

    ISO 9001:2000 Cert. N°4500/1 Table 15. Alarms window Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) Temperature Case temperature over 75°C, the maximum Absolute High endurable limit.  Check alarm and warning thresholds Temperature level goes over the alarm ...
  • Page 351 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) GPS signal is not locked by either the OCXO or the GPS receiver.  Check cable and GPS antenna connections GPS Not Locked The monitoring of this alarm is disabled when ...
  • Page 352 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1)  Reload the file system *.cfg *.jar *.drlin *.def *.ochf *.pwr2 *.fpga6 *.sav *.snmp *.cdef2 *.htm *.gpsf  If the frequency reference is Internal: OCXO fault  If the frequency reference is External: OCXO fault Lack of external 10 MHz...
  • Page 353 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1)  If the frequency reference is Internal: OCXO fault  If the frequency reference is External: OCXO fault Lack of external 1PPS 1PPS is not locked to the selected frequency 1PPS Not Locked reference.
  • Page 354 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) Power Supply voltage out of range. This alarm is risen when at least one of the following conditions is met: PS Voltage Out Of  Hardware fault Range ...
  • Page 355 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1)  Check the capability of the current modulation [DVB-T2] Input scheme Selected TS input overflow. Overflow  Check if the configuration has been loaded [DVB-T2] FE Not Logical AND between FE TS lock and FE ...
  • Page 356 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1)  Check the configuration [DVB-T2] MEAS MER Measure MER goes under the alarm threshold.  Check if the configuration has been loaded  Check the configuration [DVB-T2] MEAS Measure Signal Quality goes under the alarm Signal Quality Low threshold.
  • Page 357 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) [DVB-T2] MEAS RF output LDPC iteration per minute goes  Check input signal LDPC Mean Err over the alarm threshold. The logical OR of the following conditions: ...
  • Page 358 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) Seamless improper working warning An error has been detected on Logical seamless input. The possible errors which may be detected on input are:  PAT error  MIP error ...
  • Page 359 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) MIP packets missing. This alarm’s RF OFF mask should always be enabled. Alarm raising limitations: The monitoring of this alarm is enabled only  [DVB-T] MIP Err Check input signal when the device has SFN modulation enabled.
  • Page 360 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) Front-End MER goes under the alarm  [DVB-T] FE MER Low Check input signal and cable threshold. [DVB-T] FE Signal Front-End Signal Quality goes under the  Check input signal and cable Quality Low alarm threshold.
  • Page 361 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) Selected Input video standard (525 or 625  Check input format [ITU] Input Wrong lines) not compatible with the ARK6 definition Standard  Check input statistics standard. An alarm that is raised when the Holdover function is enabled and the set timeout period ...
  • Page 362 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) The layer Rate alarm is on when the layer input bitrate is over/under the expected  Check input bitrate [ISDB-T] Rate error bitrate. ISDB-T Layer B  Check modulation parameter setting Expected bit-rate depends on modulation parameter setting...
  • Page 363 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1)  Check the configuration [ISDB-T] MEAS MER Measure MER goes under the alarm ISDB-T Layer A threshold.  Hardware fault  Check the configuration [ISDB-T] MEAS MER Measure MER goes under the alarm ISDB-T Layer B...
  • Page 364 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) [ISDB-T] FE MER Front-End MER goes over the alarm  Check input signal and cable ISDB-T Layer B threshold. [ISDB-T] FE MER Front-End MER goes over the alarm ...
  • Page 365 ISO 9001:2000 Cert. N°4500/1 Alarm Description and limitations Troubleshooting Mode(2) RF mask (1) [ATSC] MEAS SNR Measure SNR goes under the alarm  Check the configuration ATSC threshold. [ATSC] FE ATSC demodulator of the Front-End board  Demodulator Not Check input signal ATSC not locked.
  • Page 366: Events

    ISO 9001:2000 Cert. N°4500/1 5.17 Events Click on Events button, highlighted in the next figure, to access the events windows. Figure 83. Events window Open the Events window to slide the events list. Events are reported with the following information: ...
  • Page 367: Table 16. Events Descriptions List

    ISO 9001:2000 Cert. N°4500/1 Each event type is characterized by a different colour, the following list explain the mean of each colour:  Red: alarm (refer to alarms list in Alarms paragraph and to Alarms list table);  Green: command (See ARK6_SW_Reference manual_v1_0.doc for further information); ...
  • Page 368 ISO 9001:2000 Cert. N°4500/1 Description-Event Event Description This event is reported when one of the following alarms is raised:  PS1/2 50V voltage out range  PS1/2 50V current out of range PS Restart The fourth time one of the preceding alarms is raised the amplifier is restarted (from 1 up to 4 times).
  • Page 369 ISO 9001:2000 Cert. N°4500/1 Description-Event Event Description When Input Select Mode is set on Autoswitch and the selected input is not locked the device switch to the next available locked input (refer Task Error Event paragraph) and this event is generated. string: ...
  • Page 370 ISO 9001:2000 Cert. N°4500/1 Description-Event Event Description An error occurs during saving linear precorrection coefficients. xx: error code:  0x80: File system busy;  0x01: New *.drlin file opening error;  0x02: number of coefficients information writing error;  Save drlin err: 0x03: linear coefficients writing error;...
  • Page 371: Table 17. Alarms Descriptions List

    ISO 9001:2000 Cert. N°4500/1 Description-Event Event Description Condition 1: the clock reference is changed and the OCXO is not Holdover OFF locked yet. Condition 2: the input clock reference is not present. The OCXO is locked to the selected frequency reference and the Holdover SFN Ready system is waiting for the OCXO stabilization.
  • Page 372 ISO 9001:2000 Cert. N°4500/1 Alarm Description-Alarm 960MHz Not Locked 960MHz Not Locked Input PLL Not Locked Input PLL Not Locked Output PLL Not Locked Out PLL Not Locked 10MHz Not Locked 10MHz Not Locked 1PPS Not Locked 1PPS Not Locked FPGA Boot Error FPGA Boot Err Forward Power High...
  • Page 373 ISO 9001:2000 Cert. N°4500/1 Alarm Description-Alarm [DVB-T2] MEAS MER Low Meas MER Low [DVB-T2] MEAS Signal Quality Low Meas S.Quality Low [DVB-T2] T2-MI Err T2-MI Err [DVB-T2] T2-MIP Err T2-MIP Err [DVB-T2] Holdover Holdover [DVB-T2] PPS Phase PPS Phase [DVB-T2] Configuration Not Loaded Cfg.
  • Page 374 ISO 9001:2000 Cert. N°4500/1 Alarm Description-Alarm [DVB-T] MEAS SNR Low Meas SNR Low [DVB-T] MEAS MER Low Meas MER Low [DVB-T] MEAS Signal Quality Low Meas S.Quality Low [DVB-T] Holdover Holdover [ITU] No Video Input Input not detect [ITU] Input wrong format Wrong standard [ITU] Holdover Holdover...
  • Page 375 ISO 9001:2000 Cert. N°4500/1 Alarm Description-Alarm [ISDB-T] FE CN Low FE C/N Low [ISDB-T] FE MER Layer A FE MER A Low [ISDB-T] FE MER Layer B FE MER B Low [ISDB-T] FE MER Layer C FE MER C Low [ISDB-T] FE Pre-Viterbi BER High Layer A FE Pre Vit A BER [ISDB-T] FE Pre-Viterbi BER High Layer B...
  • Page 376: Date And Time Setting

    ISO 9001:2000 Cert. N°4500/1 5.17.1 Date and Time Setting The upper part of the event window shows the actual time and date and allows the manual setting of those parameters. Figure 84. Time and date setting Click to each part of the date and time to change the parameter and then increase or decrease its value with the up/down arrows.
  • Page 377: System Error Event

    ISO 9001:2000 Cert. N°4500/1 TASK Description WD_TCP_IP_TASK This task implements the TCP-IP protocol stack. WD_TIMER_TICK_TASK This task generates the clock for the TCP-IP task. This task gathers information from both the HP and LP tuners WD_STV0362_TASK and configures them. This task gathers information from: ...
  • Page 378: System Initialization Event

    ISO 9001:2000 Cert. N°4500/1 5.17.4 System Initialization Event At every system initialization the event System Init is generated. This event is followed by 25 bytes specifying type and specific code of errors occurred during system initialization. Each byte refers to an error as described in the following table: Table 19.
  • Page 379 ISO 9001:2000 Cert. N°4500/1 Description Errors code Byte  0x00: File ok.  0x01: Current AGC mode file not found.  0x02: Current AGC mode file open error.  0x03…0x12: Invalid current AGC mode file (syntax error). CALIB_ERR  9° 0x20: Other AGC mode file not found *.pwr file error.
  • Page 380 ISO 9001:2000 Cert. N°4500/1 Description Errors code Byte  0x00: File ok.  0x01: File not found.  0x02: File open error.  0x03: syntax error or lack of input number of channels.  0x13: syntax error or lack of output number of channels. ...
  • Page 381: System Menu

    ISO 9001:2000 Cert. N°4500/1 5.18 System menu Figure 85. Menu bar The menu bar allows the access to three menus:  File: allows to import/export the configuration file, to load and save the board configuration and to download the screenshots of the Java GUI; ...
  • Page 382: View Menu

    ISO 9001:2000 Cert. N°4500/1 5.18.2 View Menu Figure 87. View menu The View menu allows accessing the following windows:  Home Page  Input  Front-End  ISDB-T Processing  ITU Processing  DVB-T Processing  ATSC Processing  DVB-T2 Processing ...
  • Page 383: Options Window

    ISO 9001:2000 Cert. N°4500/1 5.18.2.1 Options window The Options window has two tabs:  Time: Time Read Interval [s];  Alerts: the selection of events to display. Click on the Save button to save Java options; a new *.properties file will be created. The device is not loaded with a factory default *.properties file, but it is created and then stored in System File once properties are saved for the first time.
  • Page 384: Figure 90. Alert Message

    ISO 9001:2000 Cert. N°4500/1 The selection is performed among the following types of event:  Commands (blue boxes): Gigabit Ethernet commands; RS232 commands; SNMP commands; LCD Display commands.  Alarms (red boxes);  Events (green messages): Board events.  Typing error (yellow messages): Typed setting is incorrect.
  • Page 385: Help Menu

    ISO 9001:2000 Cert. N°4500/1 5.18.3 Help Menu Figure 91. Help menu The Help menu allows to select one of the following options:  Contents: Help with an abstract of the User Manual.  About: shows the board name and the management IP address. It also provides uC, FPGA, Java and GPS software versions.
  • Page 386: Figure 93. Info Window: Serial Numbers

    ISO 9001:2000 Cert. N°4500/1  Info: shows serial numbers of HW components, File System content and the managed system characteristics. Click on OK button to close Info window. Figure 93. Info window: Serial Numbers Figure 94. Info window: Server File System Content Figure 95.
  • Page 387: Download Software Standalone

    ISO 9001:2000 Cert. N°4500/1 5.19 Download Software Standalone The Download Software Standalone button allows the downloading of standalone Java application (executable *.jar file) based on java applet. If your browser is Internet Explorer, it may block the site from downloading files to your computer. If you want to enable the file downloading, follow the instructions listed below: ...
  • Page 388: Local User Interface

    ISO 9001:2000 Cert. N°4500/1 6 Local User Interface The following paragraphs describe the local user interface for ARK6 T2. This user interface is composed of LCD Display, seven buttons and two status LEDs. Here below is depicted the ARK6 Front Panel. ESCAPE ALARM STANB-BY...
  • Page 389: Boot And Welcome Message

    ISO 9001:2000 Cert. N°4500/1 6.1 Boot and Welcome Message Turning on the equipment, the display shows the progress bar as follow: Screen Service Screen Service ARK - DVB-T2 ARK - DVB-T2 System Init Boot FPGA Init : [ Wait Init : [...
  • Page 390: Idle Menu

    ISO 9001:2000 Cert. N°4500/1 6.2 Idle Menu ARK - DVB-T2 In:ASI1 17.1dBm CH:22 UTC: 14:11 10/03/11 This menu appears after one minute waiting from the last touch. Information contained in the Idle Menu are described in next table. Table 20. Local User Interface: Idle Menu Information Description...
  • Page 391: Main Menu

    ISO 9001:2000 Cert. N°4500/1 6.3 Main Menu Events Network setup Time & Date setup OK: SET This menu shows six SUBMENUs. It is possible to view them sliding the menu up and down, with the UP or DOWN ARROWS, and to select one of them by pushing OK button. Submenus contained in the Main Menu are described in next table.
  • Page 392: Lcd Alarms

    ISO 9001:2000 Cert. N°4500/1 6.4 LCD Alarms Through the LCD Alarms mask it is possible to select which alarm has to be notified on LCD display. When an alarm condition occurs the alarm button is lighted and an alarm message is displayed in the Alarms submenu.
  • Page 393 ISO 9001:2000 Cert. N°4500/1 Alarm Alarm Message PS Voltage Out Of Range PS1V Out Of Range PS Current Out Of Range PS1I Out Of Range CPU Fan Error CPU Fan Error Test Mode Test Mode FE S2 Not Locked FE S2 not locked FE S2 S/N Low FE S2 SNR Low FE S2 BER High...
  • Page 394 ISO 9001:2000 Cert. N°4500/1 Alarm Alarm Message [DVB-T2] SFN Alarm SFN Alarm [DVB-T] Input Not Present In. not present [DVB-T] Input Not valid Alarm In. not valid [DVB-T] MIP Delay High MIP delay high [DVB-T] No Input In. not detected [DVB-T] Input Overflow Input overflow [DVB-T] MIP Err...
  • Page 395 ISO 9001:2000 Cert. N°4500/1 Alarm Alarm Message [ISDB-T] Network delay Network Delay [ISDB-T] Rate error Layer A LayerA Err Rate [ISDB-T] Rate error Layer B LayerB Err Rate [ISDB-T] Rate error Layer C LayerC Err Rate [ISDB-T] Table Overflow Layer A Lay A Table ovfl [ISDB-T] Table Overflow Layer B Lay B Table ovfl...
  • Page 396 ISO 9001:2000 Cert. N°4500/1 Alarm Alarm Message [ATSC] MEAS Demodulator Not Locked Meas Not Locked [ATSC] MEAS SNR Low Meas SNR Low [ATSC] FE Demodulator Not Locked FE Not Locked [ATSC] FE SNR Low FE SNR Low Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 396 of 468...
  • Page 397: Snmp - Simple Network Management Protocol

    ISO 9001:2000 Cert. N°4500/1 7 SNMP – Simple Network Management Protocol The SNMP model assumes the existence of managers and agents. A manager is a software module in a management system responsible for managing the device. An agent is a software module in a managed device responsible for maintaining local management information and delivering that information to a manager via SNMP.
  • Page 398: Snmp Protocol Preferences

    ISO 9001:2000 Cert. N°4500/1 7.1 SNMP Protocol Preferences Go to SNMP Protocol Preferences. The following parameters should be set in order to correctly configure the SNMP Manager: SNMP protocol version: SNMPv1/SNMPv2; Read Community: the same of the one set in the Get field of Java interface, community section; Set Community: the same of the one set in the Set field of Java interface, community section;...
  • Page 399: Monitoring

    ISO 9001:2000 Cert. N°4500/1 7.2 Monitoring All status and setup information can be queried via SNMP. To get the setup and status information you need a management system (or a special MIB browser). Next figure, referring to MG-SOFT MIB Browser as an example, is a broad view of the ARK6 tree structure.
  • Page 400 ISO 9001:2000 Cert. N°4500/1 The SSBT MIBs are:  ssbt: root OID of SSBT’s enterprise tree.  ssbt-common-types: the MIB module housing SSBT Textual Conventions.  ssbtAtscModulation: the MIB module to manage the equipment configuration when operated in ATSC mode. ...
  • Page 401 ISO 9001:2000 Cert. N°4500/1  ssbtAtscFrontEnd: the MIB module to manage and monitor information from ATSC Front-End. Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 401 of 468...
  • Page 402: Table 23. Ark6 Snmp Tree Structure

    ISO 9001:2000 Cert. N°4500/1 Table 23. ARK6 SNMP Tree Structure Name Description 1.3.6 1.3.6.1 internet 1.3.6.1.2 mgmt 1.3.6.1.2.1 mib-2 1.3.6.1.2.1.1 system A textual description of the entity. This value includes the 1.3.6.1.2.1.1.1 sysDescr full name and version identification of the system" 1.3.6.1.2.1.1.2 sysObjectID 1.3.6.1.2.1.1.3...
  • Page 403 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.303.2.3.1 utcDate UTC date and time as specified in SNMPv2-TC 1.3.6.1.4.1.21678.303.2.4 gpsLockStatus GPS lock status derived from live data provided by the 1.3.6.1.4.1.21678.303.2.4.1 glsGps GPS receiver 1.3.6.1.4.1.21678.303.3 ocxo 1.3.6.1.4.1.21678.303.3.1 fineFreqAdjust Enables the Holdover mechanism 1.3.6.1.4.1.21678.303.3.2 dataToFlash Sets the timeout of the Holdover in hour...
  • Page 404 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.306.5.2.1.2 fansDescr Fan description 1.3.6.1.4.1.21678.306.5.2.1.3 fansMeasUnit Fan speed unit of measurement 1.3.6.1.4.1.21678.306.5.2.1.4 fansSpeed Fan speed 1.3.6.1.4.1.21678.306.6 temperatures The number of temperature sensors present on this 1.3.6.1.4.1.21678.306.6.1 tempNumber system 1.3.6.1.4.1.21678.306.6.2 tempTable 1.3.6.1.4.1.21678.306.6.2.1 tempEntry 1.3.6.1.4.1.21678.306.6.2.1.1 tempIndex 1.3.6.1.4.1.21678.306.6.2.1.2 tempDescr Temperature indicator description...
  • Page 405 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.307.1.2 isT2InputAutoswitch 1.3.6.1.4.1.21678.307.1.2.1 ist2iaEnable Enables the use of Input Autoswitch finite-state machine 1.3.6.1.4.1.21678.307.1.2.2 ist2iaState Current state of the finite-state machine 1.3.6.1.4.1.21678.307.1.2.3 ist2iaActualInput Shows the currently used input Primary to secondary input switch countdown expressed 1.3.6.1.4.1.21678.307.1.2.4 ist2iaPrimaryToSecondaryCounter in seconds...
  • Page 406 ISO 9001:2000 Cert. N°4500/1 Name Description Enables the PAT CRC alarm bit in the Seamless Alarm 1.3.6.1.4.1.21678.307.1.4.3.2.1.3 istsssaPatCrcEn Mask Enables the MIP CRC alarm bit in the Seamless Alarm 1.3.6.1.4.1.21678.307.1.4.3.2.1.4 istsssaMipCrcEn Mask 1.3.6.1.4.1.21678.307.1.4.3.2.1.5 istsssaSyncErrEn Enables the Sync alarm bit in the Seamless Alarm Mask Enables the Packet Jitter alarm bit in the Seamless Alarm 1.3.6.1.4.1.21678.307.1.4.3.2.1.6 istsssaPktJitterEn...
  • Page 407 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.307.1.7.3 isaiaActualInput Shows the currently used input Primary to secondary input switch countdown expressed 1.3.6.1.4.1.21678.307.1.7.4 isaiaPrimaryToSecondaryCounter in seconds Secondary to secondary input switch countdown 1.3.6.1.4.1.21678.307.1.7.5 isaiaSecondaryToSecondaryCounter expressed in seconds Secondary to primary input switch countdown expressed 1.3.6.1.4.1.21678.307.1.7.6 isaiaSecondaryToPrimaryCounter in seconds...
  • Page 408 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.307.2.3.1 sdiNumber Number of SDI inputs. 1.3.6.1.4.1.21678.307.2.3.2 sdiTable 1.3.6.1.4.1.21678.307.2.3.2.1 sdiEntry 1.3.6.1.4.1.21678.307.2.3.2.1.1 sdiIndex Index of the specific entry 1.3.6.1.4.1.21678.307.2.3.2.1.2 sdiDescr SDI input description 1.3.6.1.4.1.21678.307.2.3.2.1.3 sdiLock SDI lock status 1.3.6.1.4.1.21678.307.2.3.2.1.4 sdiCarrierDetectAlarm SDI carrier detect alarm 1.3.6.1.4.1.21678.307.2.3.2.1.5 sdiCh12Present SDI audio channels 1-2 are present SDI audio channel 1 level expressed in dBFS (-128...
  • Page 409 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.307.3.1.3 t2fesIfAgc Input IF AGC level 1.3.6.1.4.1.21678.307.3.1.4 t2fesRfAgc Input RF AGC level 1.3.6.1.4.1.21678.307.3.1.5 t2fesTsLock Demodulated TS Lock 1.3.6.1.4.1.21678.307.3.1.6 t2fesSyncStat Sync statistics 1.3.6.1.4.1.21678.307.3.1.7 t2fesMer Input MER [dBx1e3] 1.3.6.1.4.1.21678.307.3.1.8 t2fesSnr Input SNR [dBx1e3] 1.3.6.1.4.1.21678.307.3.1.9 t2fesPreLdpcBer Input Pre LDPC BER [1e7] 1.3.6.1.4.1.21678.307.3.1.10 t2fesPostBchFer Input Post BCH FER [1e6]...
  • Page 410 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.307.3.2.23 t2feL1PreL1PostExt L1 Post extension enabled 1.3.6.1.4.1.21678.307.3.2.24 t2feL1PreRfIndex The current RF index 1.3.6.1.4.1.21678.307.3.3 t2feL1Post 1.3.6.1.4.1.21678.307.3.3.1 t2feL1PostSubSliceNum Number of sub-slices per frame 1.3.6.1.4.1.21678.307.3.3.2 t2feL1PostFefType The type of the associated FEF part 1.3.6.1.4.1.21678.307.3.3.3 t2feL1PostFefLength FEF length 1.3.6.1.4.1.21678.307.3.3.4 t2feL1PostFefInterval FEF interval...
  • Page 411 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.307.3.3.7.2.1.12 t2feL1PostPlpFec The FEC type used by the associated PLP 1.3.6.1.4.1.21678.307.3.3.7.2.1.13 t2feL1PostNumBlocksMax Maximum number of PLP blocks 1.3.6.1.4.1.21678.307.3.3.7.2.1.14 t2feL1PostFrameInterval Frame interval 1.3.6.1.4.1.21678.307.3.3.7.2.1.15 t2feL1PostTimeIntLength Time interleaving length 1.3.6.1.4.1.21678.307.3.3.7.2.1.16 t2feL1PostTimeIntType Time interleaving type 1.3.6.1.4.1.21678.307.3.3.7.2.1.17 t2feL1PostInbandA In-band A flag 1.3.6.1.4.1.21678.307.3.3.7.2.1.18 t2feL1PostInbandB In-band B flag...
  • Page 412 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.307.5 s2FrontEnd 1.3.6.1.4.1.21678.307.5.1 s2feSettngs 1.3.6.1.4.1.21678.307.5.1.1 s2feFrequency Frequency [MHz] 1.3.6.1.4.1.21678.307.5.1.2 s2feSymbolRate Symbol Rate [KBaud] 1.3.6.1.4.1.21678.307.5.1.3 s2fePolarization Polarization 1.3.6.1.4.1.21678.307.5.1.4 s2feIsiA Input Stream Identifier A 1.3.6.1.4.1.21678.307.5.1.5 s2feIsiB Input Stream Identifier B 1.3.6.1.4.1.21678.307.5.1.6 s2fePls 1.3.6.1.4.1.21678.307.5.1.6.1 s2fepMode Mode selector 1.3.6.1.4.1.21678.307.5.1.6.2 s2fepN0 PLS number 0 setting...
  • Page 413 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.307.6.2 ifeLayerStatistics 1.3.6.1.4.1.21678.307.6.2.1 ifelsNumber The number of Layers 1.3.6.1.4.1.21678.307.6.2.2 ifelsTable 1.3.6.1.4.1.21678.307.6.2.2.1 ifelsEntry 1.3.6.1.4.1.21678.307.6.2.2.1.1 ifelsIndex 1.3.6.1.4.1.21678.307.6.2.2.1.2 ifelsDescr Layer description 1.3.6.1.4.1.21678.307.6.2.2.1.3 ifelsMod Modulation scheme 1.3.6.1.4.1.21678.307.6.2.2.1.4 ifelsCodeRate Code rate 1.3.6.1.4.1.21678.307.6.2.2.1.5 ifelsTILength Time Interleaving length 1.3.6.1.4.1.21678.307.6.2.2.1.6 ifelsSegNum Number of segments 1.3.6.1.4.1.21678.307.6.2.2.1.7 ifelsMer MER [dB] (* 10)
  • Page 414 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.308.1.6 imsEWS Enables the local editing of the Emergency switch on 1.3.6.1.4.1.21678.308.1.6.1 imsewsEnable control flag 1.3.6.1.4.1.21678.308.1.6.2 imsewsSetting Sets the Emergency switch on control flag 1.3.6.1.4.1.21678.308.1.7 imsLayersMonitor 1.3.6.1.4.1.21678.308.1.7.1 imslmNumber The number of Layers 1.3.6.1.4.1.21678.308.1.7.2 imslmTable 1.3.6.1.4.1.21678.308.1.7.2.1 imslmEntry 1.3.6.1.4.1.21678.308.1.7.2.1.1...
  • Page 415 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.308.3.5 imlpLayers 1.3.6.1.4.1.21678.308.3.5.1 imlplNumber The number of Layers 1.3.6.1.4.1.21678.308.3.5.2 imlplTable 1.3.6.1.4.1.21678.308.3.5.2.1 imlplEntry 1.3.6.1.4.1.21678.308.3.5.2.1.1 imlplIndex 1.3.6.1.4.1.21678.308.3.5.2.1.2 imlplDescr Layer description 1.3.6.1.4.1.21678.308.3.5.2.1.3 imlplMod Modulation scheme 1.3.6.1.4.1.21678.308.3.5.2.1.4 imlplCodeRate Code rate of inner code 1.3.6.1.4.1.21678.308.3.5.2.1.5 imlplTILength Time Interleaving length 1.3.6.1.4.1.21678.308.3.5.2.1.6 imlplSegNum Number of segments...
  • Page 416 ISO 9001:2000 Cert. N°4500/1 Name Description Carrier Level 1 [dB] (range: -7 to -22) = [-1* (x/10)] (range 1.3.6.1.4.1.21678.309.2.3 itumasCarrierLevel1 70 to 220) Carrier Level 2 [dB] (range: -7 to -22) = [-1* (x/10)] (range 1.3.6.1.4.1.21678.309.2.4 itumasCarrierLevel2 70 to 220) 1.3.6.1.4.1.21678.309.2.5 itumasEmphasis Emphasis monitor...
  • Page 417 ISO 9001:2000 Cert. N°4500/1 Name Description Output frequency offset expressed in Hz (from -200 kHz 1.3.6.1.4.1.21678.310.1.1.7.2 osomioRfFreqOff up to 200 kHz) 1.3.6.1.4.1.21678.310.1.1.8 osomAOutput 1.3.6.1.4.1.21678.310.1.1.8.1 osomaoRfChannel Output channel Output frequency offset expressed in Hz (1Hz steps, from 1.3.6.1.4.1.21678.310.1.1.8.2 osomaoRfFreqOff -200 kHz to 200 kHz) 1.3.6.1.4.1.21678.310.1.1.9 osomItuOutput 1.3.6.1.4.1.21678.310.1.1.9.1...
  • Page 418 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.310.3.2.1 tsEntry 1.3.6.1.4.1.21678.310.3.2.1.1 tsIndex 1.3.6.1.4.1.21678.310.3.2.1.2 tsDescr Test signal description. 1.3.6.1.4.1.21678.310.3.2.1.3 tsEnable Test signal enable 0: disabled 1: enabled. 1.3.6.1.4.1.21678.310.3.3 tsItu 1.3.6.1.4.1.21678.310.3.3.1 video 1.3.6.1.4.1.21678.310.3.3.1.1 videoTestSel Video test signal selector 1.3.6.1.4.1.21678.310.3.3.2 audio 1.3.6.1.4.1.21678.310.3.3.2.1 audioToneEnable Enables the audio test tones 1.3.6.1.4.1.21678.310.3.3.2.2 audioToneRight Right tone frequency (range:0 to127) [unit x 100Hz]...
  • Page 419 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.311.1.3.1.5 icSourceClkReference Source clock reference selector 1.3.6.1.4.1.21678.311.2 outputChannels 1.3.6.1.4.1.21678.311.2.1 ocPort UDP port 1.3.6.1.4.1.21678.311.2.2 ocNumber Number of output Ethernet channels. 1.3.6.1.4.1.21678.311.2.3 ocTable 1.3.6.1.4.1.21678.311.2.3.1 ocEntry 1.3.6.1.4.1.21678.311.2.3.1.1 ocIndex 1.3.6.1.4.1.21678.311.2.3.1.2 ocDescr Description of output channel 1.3.6.1.4.1.21678.311.2.3.1.3 ocStatus Tansmission state 1.3.6.1.4.1.21678.311.2.3.1.4 ocDestIpAddr Destination IP address...
  • Page 420 ISO 9001:2000 Cert. N°4500/1 Name Description Enables the Automatic Frequency Loop function. This funcion allows to 1.3.6.1.4.1.21678.313.1.9 t2msAutoRfLoop automatically set the FREQUENCY field of the L1-Post signalling to the currently used RF output frequency." 1.3.6.1.4.1.21678.313.1.10 t2msPidMode 1.3.6.1.4.1.21678.313.1.10.1 t2mspmAutoPidEn Enables the automatic detection of the T2-MI PID 1.3.6.1.4.1.21678.313.1.10.2 t2mspmDetectedPid Shows the detected T2-MI PID...
  • Page 421 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.313.2.2.7 t2mcpL1PreL1Repeat L1 repeat enable flag 1.3.6.1.4.1.21678.313.2.2.8 t2mcpL1PreGuardInterval Guard Interval 1.3.6.1.4.1.21678.313.2.2.9 t2mcpL1PrePapr PAPR 1.3.6.1.4.1.21678.313.2.2.10 t2mcpL1PreL1Mod L1 modulation scheme 1.3.6.1.4.1.21678.313.2.2.11 t2mcpL1PreL1CodeRate L1 code rate 1.3.6.1.4.1.21678.313.2.2.12 t2mcpL1PreL1Fec L1 FEC Type 1.3.6.1.4.1.21678.313.2.2.13 t2mcpL1PreL1PostSize L1 Post Size 1.3.6.1.4.1.21678.313.2.2.14 t2mcpL1PreL1PostInfoSize L1 Post Info Size 1.3.6.1.4.1.21678.313.2.2.15...
  • Page 422 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.313.2.3.6.2.1.2 t2mcpL1PostRfIdx RF index 1.3.6.1.4.1.21678.313.2.3.6.2.1.3 t2mcpL1PostFrequency Frequency 1.3.6.1.4.1.21678.313.2.3.7 t2mcpL1PostPlp 1.3.6.1.4.1.21678.313.2.3.7.1 t2mcpL1PostPlpNum Number of PLPs 1.3.6.1.4.1.21678.313.2.3.7.2 t2mcpL1PostPlpTable 1.3.6.1.4.1.21678.313.2.3.7.2.1 t2mcpL1PostPlpEntry 1.3.6.1.4.1.21678.313.2.3.7.2.1.1 t2mcpL1PostPlpIndex 1.3.6.1.4.1.21678.313.2.3.7.2.1.2 t2mcpL1PostPlpId PLP ID 1.3.6.1.4.1.21678.313.2.3.7.2.1.3 t2mcpL1PostPlpType PLP type 1.3.6.1.4.1.21678.313.2.3.7.2.1.4 t2mcpL1PostPlpPayloadType PLP payload type 1.3.6.1.4.1.21678.313.2.3.7.2.1.5 t2mcpL1PostFfFlag FF flag 1.3.6.1.4.1.21678.313.2.3.7.2.1.6...
  • Page 423 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.313.3.1.8 t2mlL1PreGuardInterval Guard Interval 1.3.6.1.4.1.21678.313.3.1.9 t2mlL1PrePapr PAPR 1.3.6.1.4.1.21678.313.3.1.10 t2mlL1PreL1Mod L1 modulation scheme 1.3.6.1.4.1.21678.313.3.1.11 t2mlL1PreL1CodeRate L1 code rate 1.3.6.1.4.1.21678.313.3.1.12 t2mlL1PreL1Fec L1 FEC Type 1.3.6.1.4.1.21678.313.3.1.13 t2mlL1PreL1PostSize L1 Post Size 1.3.6.1.4.1.21678.313.3.1.14 t2mlL1PreL1PostInfoSize L1 Post Info Size 1.3.6.1.4.1.21678.313.3.1.15 t2mlL1PrePilotPattern Pilot Pattern 1.3.6.1.4.1.21678.313.3.1.16...
  • Page 424 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.313.3.2.6.2.1.3 t2LL1PostFrequency Frequency 1.3.6.1.4.1.21678.313.3.2.7 t2mlL1PostPlp 1.3.6.1.4.1.21678.313.3.2.7.1 t2mlL1PostPlpNum Number of PLPs 1.3.6.1.4.1.21678.313.3.2.7.2 t2mlL1PostPlpTable 1.3.6.1.4.1.21678.313.3.2.7.2.1 t2mlL1PostPlpEntry 1.3.6.1.4.1.21678.313.3.2.7.2.1.1 t2mlL1PostPlpIndex 1.3.6.1.4.1.21678.313.3.2.7.2.1.2 t2mlL1StreamFormat Input stream format 1.3.6.1.4.1.21678.313.3.2.7.2.1.3 t2mlL1SisMis Single or multiple input streams 1.3.6.1.4.1.21678.313.3.2.7.2.1.4 t2mlL1CcmAcm Input stream format 1.3.6.1.4.1.21678.313.3.2.7.2.1.5 t2mlL1Issyi Input stream sinchronization indicator 1.3.6.1.4.1.21678.313.3.2.7.2.1.6...
  • Page 425 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.315.1 t2Measure 1.3.6.1.4.1.21678.315.1.1 t2mStatistics Output RX level 127: over input -128: low power - 1.3.6.1.4.1.21678.315.1.1.1 meas1RxLevel 63...62: power expressed in dB Output RX level 127: over input -128: low power - 1.3.6.1.4.1.21678.315.1.1.2 meas2RxLevel 63...62: power expressed in dB 1.3.6.1.4.1.21678.315.1.1.3 measCarrierOffset Output carrier offset...
  • Page 426 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.315.1.2.17 t2mL1PreCellId Cell Id 1.3.6.1.4.1.21678.315.1.2.18 t2mL1PreT2NetworkId T2 Network Id 1.3.6.1.4.1.21678.315.1.2.19 t2mL1PreT2SystemId T2 System Id 1.3.6.1.4.1.21678.315.1.2.20 t2mL1PreNumT2Frames Number of T2 frames 1.3.6.1.4.1.21678.315.1.2.21 t2mL1PreNumDataSymb Number of data symbols 1.3.6.1.4.1.21678.315.1.2.22 t2mL1PreRegenFlag Regeneration count indicator 1.3.6.1.4.1.21678.315.1.2.23 t2mL1PreL1PostExt L1 Post extension enabled 1.3.6.1.4.1.21678.315.1.2.24 t2mL1PreRfIndex The current RF index...
  • Page 427 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.315.1.3.7.2.1.6 t2mL1PostFirstRfIdx First RF index 1.3.6.1.4.1.21678.315.1.3.7.2.1.7 t2mL1PostFirstFrameIdx First frame index 1.3.6.1.4.1.21678.315.1.3.7.2.1.8 t2mL1PostGroupId PLP group id 1.3.6.1.4.1.21678.315.1.3.7.2.1.9 t2mL1PostPlpCod The code rate used by the associated PLP 1.3.6.1.4.1.21678.315.1.3.7.2.1.10 t2mL1PostPlpMod The modulation used by the associated PLP 1.3.6.1.4.1.21678.315.1.3.7.2.1.11 t2mL1PostPlpRotation DVBT2 rotated constellation indicator...
  • Page 428 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.315.2.2.4 tmdpLpCodeRate Low Priority Code Rate 1.3.6.1.4.1.21678.315.2.2.5 tmdpFft FFT size 1.3.6.1.4.1.21678.315.2.2.6 tmdpGuardInterval Guard interval 1.3.6.1.4.1.21678.315.2.2.7 tmdpCelllId Cell identifier 1.3.6.1.4.1.21678.315.3 isdbtMeasure 1.3.6.1.4.1.21678.315.3.1 imStatistics Output TX level monitor 127: over input -128: low power 1.3.6.1.4.1.21678.315.3.1.1 imsMonTxLevel -63...62: power expressed in dB 1.3.6.1.4.1.21678.315.3.1.2 imsIfLevel...
  • Page 429 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.315.4.1.5 amsAgcLock Digital AGC lock status 1.3.6.1.4.1.21678.315.4.1.6 amsFrameLock Frame lock status 1.3.6.1.4.1.21678.315.4.1.7 amsCarrierFreqLoopLock Carrier frequency loop lock status 1.3.6.1.4.1.21678.315.4.1.8 amsTimingFreqLoopLock Timing frequency loop lock status 1.3.6.1.4.1.21678.315.4.1.9 amsSnr Signal to Noise Ratio [dB] 1.3.6.1.4.1.21678.315.4.1.10 amsSer Segment Error Rate 1.3.6.1.4.1.21678.315.4.1.11 amsBer...
  • Page 430 Code of the alarm this threshold is referred to 1.3.6.1.4.1.21678.317.4.3.2.1.4 altMeasUnit Temperature unit of measurement 1.3.6.1.4.1.21678.317.4.3.2.1.5 altSetting Threshold setting Alarms table. This table contains all alarms that can be 1.3.6.1.4.1.21678.317.4.4 alTable managed by screen service devices" 1.3.6.1.4.1.21678.317.4.4.1 alEntry 1.3.6.1.4.1.21678.317.4.4.1.1 alIndex Alarm index 1.3.6.1.4.1.21678.317.4.4.1.2 alStatus Alarm status 1.3.6.1.4.1.21678.317.4.4.1.3...
  • Page 431 ISO 9001:2000 Cert. N°4500/1 Name Description Enables relay 1 to be switched on/off depending on the 1.3.6.1.4.1.21678.317.4.4.1.10 alR1Enable status of this alarm" Enables relay 2 to be switched on/off depending on the 1.3.6.1.4.1.21678.317.4.4.1.11 alR2Enable status of this alarm" Enables relay 3 to be switched on/off depending on the 1.3.6.1.4.1.21678.317.4.4.1.12 alR3Enable status of this alarm"...
  • Page 432 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.317.6.2.2.1.1 mmIndex Mode index 1.3.6.1.4.1.21678.317.6.2.2.1.2 mmType Mode type 1.3.6.1.4.1.21678.317.6.2.2.1.3 mmStatus Mode status 1.3.6.1.4.1.21678.321 ssbtNetwork 1.3.6.1.4.1.21678.321.1 netInterfaces 1.3.6.1.4.1.21678.321.1.1 nifNumber The number of network interfaces 1.3.6.1.4.1.21678.321.1.2 nifTable 1.3.6.1.4.1.21678.321.1.2.1 nifEntry 1.3.6.1.4.1.21678.321.1.2.1.1 nifIndex 1.3.6.1.4.1.21678.321.1.2.1.2 nifDescr Interface description 1.3.6.1.4.1.21678.321.1.2.1.3 nifType The type of interface 1.3.6.1.4.1.21678.321.1.2.1.4...
  • Page 433 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.325.2.2.2 tmmpdpTimeSlicingLp MIP Low Priority Time Slicing 1.3.6.1.4.1.21678.325.2.2.3 tmmpdpMpeFecHp High Priority MPE-FEC 1.3.6.1.4.1.21678.325.2.2.4 tmmpdpMpeFecLp Low Priority MPE-FEC 1.3.6.1.4.1.21678.325.2.2.5 tmmpdpInterleaver MIP native/in-depth symbol interleaver selector 1.3.6.1.4.1.21678.325.2.3 tmmpMipFunctions 1.3.6.1.4.1.21678.325.2.3.1 tmmpmfTxId 1.3.6.1.4.1.21678.325.2.3.1.1 tmmpmftiNumber Transmitter identifier 1.3.6.1.4.1.21678.325.2.3.1.2 tmmpmftiEnableTxId0 Enables the TX ID 0 1.3.6.1.4.1.21678.325.2.3.2 tmmpmfCellId...
  • Page 434 ISO 9001:2000 Cert. N°4500/1 Name Description 1.3.6.1.4.1.21678.325.3.3.1 tmlpmfCellIdEnable Enables the use of the locally set Cell ID 1.3.6.1.4.1.21678.325.3.3.2 tmlpmfCellId Local cell id setting 1.3.6.1.4.1.21678.325.3.3.3 tmlpmflDelay User delay setting 100ns] 1.3.6.1.4.1.21678.325.3.3.4 tmlpmfFrequencyOffset Frequency offset setting [Hz] 1.3.6.1.4.1.21678.325.3.3.5 tmlpmfTimeOffset Time offset setting [100ns] 1.3.6.1.4.1.21678.325.4 tmCurrentParameters 1.3.6.1.4.1.21678.325.4.1...
  • Page 435: Events Monitoring

    ISO 9001:2000 Cert. N°4500/1 7.3 Events Monitoring In MIB ssbtCommon the events node allows the monitoring of events. evNumber object specifies the total number of events stored in memory. evOverwritten object notifies if the events list exceeded the memory limit. If this object returns “1”, obsolete events have begun to be overwritten.
  • Page 436: Configuring Alarm Masks And Alarm Thresholds

    ISO 9001:2000 Cert. N°4500/1 7.4 Configuring alarm masks and alarm thresholds In ssbtCommon MIB the alarms node allows the monitoring of alarms status, the setting of alarm masks and thresholds. 7.4.1 Alarms Table The alTable table is used to monitor alarms status and to set alarm masks. alNumber object specifies the total number of entries in the alarms table.
  • Page 437: Table 24. Alarms Code And Description

    ISO 9001:2000 Cert. N°4500/1 alMask1 object allows to enable trap messages, associated to the entry, to be sent to the manager with IP address 1 alMask2 object allows to enable trap messages, associated to the entry, to be sent to the manager with IP address 2 alMask3 object allows to enable trap messages, associated to the entry, to be sent to the manager with IP address 3...
  • Page 438 ISO 9001:2000 Cert. N°4500/1 alDescr Alarm Description Alarm Code Out PLL Not Locked Output PLL Not Locked 10MHz Not Locked 10MHz Not Locked 1PPS Not Locked 1 PPS Not Locked FPGA Boot Err FPGA Boot Error FWD Power High Forward Power High FWD Pwr Low Warning Forward Power Low Warning FWD Pwr Low...
  • Page 439 ISO 9001:2000 Cert. N°4500/1 alDescr Alarm Description Alarm Code [DVB-T2] Meas S.Quality Low [DVB-T2] Meas S.Quality Low 1324 [DVB-T2] T2-MI Err [DVB-T2] T2-MI Err 1325 [DVB-T2] T2-MIP Err [DVB-T2] T2-MIP Err 1326 [DVB-T2] Holdover [DVB-T2] Holdover 1327 [DVB-T2] PPS Phase [DVB-T2] PPS Phase 1328 [DVB-T2] Cfg.
  • Page 440 ISO 9001:2000 Cert. N°4500/1 alDescr Alarm Description Alarm Code [ITU] No Video Input [ITU] Input not detect [ITU] Input wrong format [ITU] Wrong standard [ITU] Holdover [ITU] Holdover [ISDB-T] Input Error [ISDB-T] Input not valid [ISDB-T] IIP Modulation Error [ISDB-T] IIP error [ISDB-T] 1PPS Phase [ISDB-T] PPS phase wrong [ISDB-T] System delay...
  • Page 441 ISO 9001:2000 Cert. N°4500/1 alDescr Alarm Description Alarm Code [ISDB-T] FE Pre-Viterbi BER High Layer A [ISDB-T] FE Pre Vit A BER [ISDB-T] FE Pre-Viterbi BER High Layer B [ISDB-T] FE Pre Vit B BER [ISDB-T] FE Pre-Viterbi BER High Layer C [ISDB-T] FE Pre Vit C BER [ISDB-T] FE Emergency Flag [ISDB-T] FE emergency flag...
  • Page 442: Thresholds Table

    ISO 9001:2000 Cert. N°4500/1 7.4.2 Thresholds Table The alThresholds subtree is used to set alarms thresholds. altNumber object specifies the total number of entries in the alarm thresholds table. Each entry in the table is defined as follows: AltEntry ::= SEQUENCE { altIndex INTEGER, altDescr DisplayString, altAlarmCode INTEGER,...
  • Page 443: Table 25. Alarm Thresholds Description

    ISO 9001:2000 Cert. N°4500/1 Table 25. Alarm Thresholds Description altDescr Threshold Description Alarm Code Temp. High -3dB Temperature alarm threshold expressed in °C. Temp. High Warning Temperature warning threshold expressed in °C. FWD Pwr Low Warning Forward power warning threshold expressed in dB. FWD Pwr Low Forward power alarm threshold expressed in dB.
  • Page 444 ISO 9001:2000 Cert. N°4500/1 altDescr Threshold Description Alarm Code Meas S.Quality Low [DVB-T] MEAS Signal Quality Low alarm threshold. [ATSC] FE SNR Low alarm threshold (expressed in FE SNR Low 1062 dB*1e3). [ATSC] MEAS SNR Low alarm threshold (expressed in Meas SNR Low 1060 dB*1e3).
  • Page 445: Traps

    ISO 9001:2000 Cert. N°4500/1 7.5 Traps While a management station can poll, at fixed time interval, all the agents it knows for some key information, each agent is responsible for notifying the management station of any alarm condition. These events are communicated in SNMP messages known as traps.
  • Page 446: Figure 99. Snmpv1 Trap Messages

    ISO 9001:2000 Cert. N°4500/1 VARIABLES clause defines the ordered sequence of MIB objects, belonging to the specific entry of the alTable, which are contained within every instance of the trap type. Each variable is placed, in order, inside the variable- bindings field of the SNMP Trap Message as shown in the following figure (refer to Alarms Table paragraph for...
  • Page 447: Snmpv2

    ISO 9001:2000 Cert. N°4500/1 7.5.2 SNMPv2 ARK6 devices transmit alarm-specific traps. For every Trap Manager there is a different SNMv2 trap definition: traps OBJECT IDENTIFIER ::= { snmp 3 } alarmTraps1 NOTIFICATION-TYPE OBJECTS {alIndex, alStatus, alCode, alDescr, alSeverity} STATUS current DESCRIPTION "Traps definition for Trap Manager 1.
  • Page 448: Figure 100. Snmpv2 Trap Messages

    ISO 9001:2000 Cert. N°4500/1 VARIABLES clause defines the ordered sequence of MIB objects, belonging to the specific entry of the alTable, which are contained within every instance of the trap type. Each variable is placed, in order, inside the variable- bindings field of the SNMP Trap Message as shown in the following figure (refer to Alarms Table paragraph for...
  • Page 449: Configuring Traps

    ISO 9001:2000 Cert. N°4500/1 7.5.3 Configuring traps Use Java (refer to Network Alarms paragraphs for further information) or SNMP user interfaces to configure traps. The configuration of traps is performed through the setting of three different alarm masks, by means of alMask1, alMask2, alMask3 objects in the alTable (refer to Alarms Table paragraph), and through the setting of...
  • Page 450: Appendix A. Automatic Input Source Selection Methods

    ISO 9001:2000 Cert. N°4500/1 Appendix A. Automatic input source selection methods Input Autoswitch The SDT ARK62 series supports an automatic switching control mechanism between incoming signal sources. The ARK6 is capable of switching between inputs on the basis of primary feed quality, depending on how it is presented to the transmitter (RF, ASI –...
  • Page 451 ISO 9001:2000 Cert. N°4500/1 Input switching rules can be selected in the Alarms page through the SWITCH alarm mask and depend on the transmission standard. Here below the available rules for each operative mode: DVB-T2 [DVB-T2] No Input: input Transport Stream not locked [DVB-T2] FE Not Locked: RF feed not locked by the T2 demodulator [DVB-T2] FE Squelch: RF input power level is under the squelch alarm threshold [DVB-T2] FE Pre LDPC BER High: RF input Pre LDPC BER goes over the alarm threshold...
  • Page 452 ISO 9001:2000 Cert. N°4500/1 ATSC [ATSC] No Input: input Transport Stream not locked [ATSC] Input Overflow: input TS overflow [ATSC] MH Err [ATSC] FE Demodulator Not Locked: input RF signal not locked [ATSC] FE SNR Low: RF input SNR under the alarm threshold [ATSC] No TVCT: TVCT table not present in the selected input stream ISDBT Version 1_2...
  • Page 453 ISO 9001:2000 Cert. N°4500/1 Feed selection and switching criteria are available via both transmitter SNMP and Java GUI interfaces. A Finite State Machine has been used to give a description of the behaviour of the system. The FSM of the Input Autoswitch algorithm consists of: ...
  • Page 454: Seamless Input Switching

    ISO 9001:2000 Cert. N°4500/1 Seamless input switching SDT ARK6 series supports a seamless input switching algorithm that increases the reliability of the system in a SFN environment. The developed algorithm is capable of changing input signal source on the basis of MIP packets within the incoming Transport Stream.
  • Page 455: Appendix B. Java Virtual Machine

    ISO 9001:2000 Cert. N°4500/1 Appendix B. Java Virtual Machine The Java interface requires a host computer connected via Ethernet to the board with the proper Java Machine version installed. Ethernet connection The host computer has to be connected via Ethernet to the board. Direct or crossed UTP category 6 cable is recommended.
  • Page 456: Appendix C. Application Note

    ISO 9001:2000 Cert. N°4500/1 Appendix C. Application Note Screenshots of this application note are used as an example and the shown file names are not related to ARK6- T2 device. How to update 1. Launch the Java installer. Figure 101. Java installer 2.
  • Page 457: Figure 103. Java Installer - Search Button

    ISO 9001:2000 Cert. N°4500/1 3. Click the Search button. Figure 103. Java Installer – Search button 4. Select the device version you want to load. Figure 104. Java Installer - Device selection Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 457 of 468...
  • Page 458: Figure 105. Java Installer - Load Button

    ISO 9001:2000 Cert. N°4500/1 5. Click on the “Load” button. Figure 105. Java Installer – Load button 6. If you want to update only some software versions, click on the check boxes corresponding to the software version you want to load, otherwise click on the check box corresponding to the Load All option.
  • Page 459: Figure 107. Java Installer - Stop Button

    ISO 9001:2000 Cert. N°4500/1 7. Once started the loading, the “Stop” button lights up. Click on this button to interrupt the programming. Figure 107. Java Installer – Stop button When the loading is complete, the pop-up window “Operation Successfully Completed” appears. Click on the “OK”...
  • Page 460 ISO 9001:2000 Cert. N°4500/1 9. To save a copy of the file system click on “Backup” button. A pop-up window “Salva” appears. Specify the saving path, then click on “Salva” button. Figure 109. Java Installer – Backup Save button Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 460 of 468...
  • Page 461: Appendix D. Document Versions

    ISO 9001:2000 Cert. N°4500/1 Appendix D. Document versions Table 26. Document Versions Version Author Revised by Date Note First version with all the Di Biase November 8th, 2011 operative modes. Updated paragraphs 4.2 and Di Biase November 23rd, 2011 4.4. Corrected ISDBT Modulation IIP Alarm, IIP Modualtion valid, IIP Porta...
  • Page 462: List Of Tables

    ISO 9001:2000 Cert. N°4500/1 List of Tables Table 1. Hardware options ........................10 Table 2. RS232 DE-9 pinout ......................... 32 Table 3. TLC pinout ..........................32 Table 4. TLS pinout ..........................33 Table 5. Input window ........................43 Table 6. Tuner window: RF power level monitor ................
  • Page 463 ISO 9001:2000 Cert. N°4500/1 Table 35. CAT parameters ........................167 Table 36. CDT parameters ........................168 Table 37. DIT parameters ........................169 Table 38. ERT parameters ........................170 Table 39. LDT parameters ........................171 Table 40. LIT parameters ........................172 Table 41.
  • Page 464 ISO 9001:2000 Cert. N°4500/1 Table 11. Output window: Reflex Pwr Management ................336 Table 12. Network window ......................... 338 Table 13. GPS window ......................... 343 Table 14. GPS window: Holdover Management ................. 346 Table 15. Alarms window ........................350 Table 16. Events descriptions list ......................
  • Page 465: List Of Figures

    ISO 9001:2000 Cert. N°4500/1 List of Figures Figure 1. DE-9 Male connector ......................32 Figure 2. TLC connector ........................32 Figure 3. TLS connector ........................33 Figure 4. GUI - Login ..........................37 Figure 5. Java menu bar ........................38 Figure 6.
  • Page 466 ISO 9001:2000 Cert. N°4500/1 Figure 35. DVB-T2 Measure: RF power level monitor ................113 Figure 36. DVB-T window ........................114 Figure 37. DVB-T Processing: DVB-T Settings ..................115 Figure 38. DVB-T Modulation: DVB-T Modulation ................123 Figure 39. DVB-T Modulation: Modulator manager ................124 Figure 40.
  • Page 467 ISO 9001:2000 Cert. N°4500/1 Figure 72. Adaptive Filter ........................321 Figure 73. Filter window: complex filter coefficients graph ..............323 Figure 74. Filter window: module graph ....................323 Figure 75. Filter window: phase graph ....................323 Figure 76. Adaptive Non Linear Precorrection ..................324 Figure 77.
  • Page 468 ISO 9001:2000 Cert. N°4500/1 Figure 109. Java Installer – Backup Save button ..................460 Version 1_2 SDT_ARK6_User_Manual_ENG_v1_2.doc Page 468 of 468...

This manual is also suitable for:

Sdt500ub

Table of Contents

Save PDF