Download Print this page

LORD G-Link-200 Quick Start Manual

Ruggedized high-speed triaxial accelerometer node

Advertisement

Quick Links

LORD QUICK START GUIDE
®
G-Link
-200
Ruggedized High-Speed Triaxial Accelerometer Node
The G- Link- 200 wireless accelerometer node features an on- board triaxial
accelerometer that allows high-resolution data acquisition at noise levels as low
as 25 or 80 µg√Hz. The G-Link-200 can output continuous waveform data, or one
of four derived channels, including Velocity (IPS
and Crest Factor, allowing long-term monitoring of key performance indicators
while maximizing battery life.
To acquire sensor data, the G- Link- 200 is used with a LORD Sensing data
gateway such as the WSDA-101 or WSDA-1500 Base. G-Link-200 sensor nodes
come with the following components.
Item
Description
A
G-Link-200
B
½ AA, 3.6 V Lithium Batteries
Table 1 - G-Link-200 Components List
Wireless Simplicity, Hardwired Reliability™
), Amplitude (G
and G
)
rms
rms
pk-pk
Quantity
1
3
The G-Link-200 LEDs indicate operational modes showing when the node
is booting up, idle and waiting for a command, sampling, resynchronizing,
or if there is an error.
Indicator
Behavior
OFF
Rapid green flashing
on start-up
Device
1 (slow) green pulse per
status
second
indicator
1 green blink every 2 seconds
Blue LED during sampling
Red LED
Table 2 - Indicator Behaviors
Node Status
Node is OFF
Node is booting up
Node is idle and waiting for a
command
Node is sampling
Node is resynchronizing
Error or low battery

Advertisement

loading
Need help?

Need help?

Do you have a question about the G-Link-200 and is the answer not in the manual?

Questions and answers

Summary of Contents for LORD G-Link-200

  • Page 1 Crest Factor, allowing long-term monitoring of key performance indicators while maximizing battery life. To acquire sensor data, the G- Link- 200 is used with a LORD Sensing data gateway such as the WSDA-101 or WSDA-1500 Base. G-Link-200 sensor nodes come with the following components.
  • Page 2: System Operation

    SensorCloud website. The into idle mode, which is used for configuring node settings, and allows toggling SensorConnect software is available on the LORD Sensing website for free between sampling and sleeping modes. The node will automatically go into the download: ultra low- power sleep mode after a user- determined period of inactivity.
  • Page 3 Node. If the base and node are on the same operating frequency, the node will populate below the Base Station listing when powering on the G-Link-200. Figure 3 - Node Discovered On Same Frequency Figure 5 - Add Node By Address If the node was successfully added, two confirmation messages will appear and it will be listed under the Base Station.
  • Page 4 ® G-Link -200 Wireless Accelerometer Node Quick Start Guide If the node failed to be added, a failure message will appear. This means Highlight the new node being added and select Move Node to Frequency the node did not respond to the base station which could indicate the (#).
  • Page 5 ® G-Link -200 Wireless Accelerometer Node Quick Start Guide 4. Select Apply and Start Network. 5. Select Create Quick View Dashboard in the pop up window immediately to create a dashboard of the new data. Figure 10 - Node Configuration 5. Configure Sampling Setting and Start Data Acquisition 1.
  • Page 6 Quick Start Guide 6. Replacing Batteries 1. Remove the cap from the G-Link-200. 2. Remove the three ½ AA batteries from the G-Link-200. 3. Insert three new ½ AA batteries (Saft LS 14250 recommended), observing the correct polarity orientation. The positive polarities are indicated on the batteries and the node by a "+"...