Vessel EYE-02 Instruction Manual

Vessel EYE-02 Instruction Manual

Static scale

Advertisement

Quality does it.
Thank you for purchasing our Static Scale No. Eye-02.
Read this instruction manual before use. Keep it in a safe handy place for future reference.

Table of Contents

■For Your Safety ····································· P.2
■Product Features ·································· P.3
■Product Specifications ··························· P.4
■Function Settings ·································· P.6
■Ion Balance Measurement ···················· P.12
■Table of Functions ································· P.18
■Troubleshooting ···································· P.19
■Warranty ··············································· P.20
Instruction Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EYE-02 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vessel EYE-02

  • Page 1: Table Of Contents

    Quality does it. Instruction Manual Thank you for purchasing our Static Scale No. Eye-02. Read this instruction manual before use. Keep it in a safe handy place for future reference. Table of Contents ■For Your Safety ····································· P.2 ■Product Features ·································· P.3 ■Product Specifications ···························...
  • Page 2: For Your Safety

    PROHIBITED fluctuations or dewing. This kind of environment can lead to breakdown. Do not use the Eye-02 in highly damp places or anywhere it may be wet by DO NOT WET water, oil, solvent or other liquid. Contact with moisture can result in electric shock or breakdown.
  • Page 3: Product Features

    Eye-02 for increased stability during measurement. Usage Use the Eye-02 to investigate places of static electricity generation and charging levels, to select the static electricity removing device (ionizer) installation place and its effect, and for daily inspection of the static electricity removing device’s performance.
  • Page 4: Product Specifications

     Bar graph display: LO range ± 0.1 kV per bar HI range + 1.5 kV per bar  Measuring distance: 25mm ±0.5mm (between charged object and the Eye-02)  Measurement range: 0 to ± 220 V Ion Balance voltage ...
  • Page 5 ■Product Specifications Accessories Ion Balance PLATE: Ground Cord: 1 (With alligator clips) Strap: Soft Case: Overview and Name of parts...
  • Page 6: Preparation And Battery Replacement

    A strap can be attached to the static electricity measuring device Eye-02. Attach the enclosed strap to the Eye-02 before starting use. Damage to the device caused by dropping can be prevented by wearing the device on your wrist during measurements.
  • Page 7 Make certain that the surface of a white plastic plate under the Ion Balance REMEMBER plate is clean before attaching it to Eye-02 for Ion Balance measurement. The Ion Balance plate should be stored or used in a place having less than REMEMBER 60 %RH.
  • Page 8: Function Settings

    ■Function Settings Selection of mode at start-up “auto power off” and “backlight” The “auto power off” and “backlight” functions can be selected if the device is started up by holding down the power button. The “auto power off” function should be turned off when performing continuous measurements. Mode 1 Mode 2 Mode 3...
  • Page 9 ■Function Settings Measurement mode selection “Static charge voltage measurement” and “Ion Balance Measurement” When the STATIC/I.B. button is pressed after starting up the device, the mode can be switched between “Static charge voltage measurement mode” and “Ion Balance measurement mode”. Static charge voltage Ion Balance voltage measurement mode...
  • Page 10 ■Function Settings Retaining the measurement value “HOLD” and “MAX” By pressing the HOLD/MAX button during a measurement, the state can be changed between “temporarily hold the measurement (HOLD)” and “hold the maximum value during measurement (MAX)”. * When “temporarily hold the measurement (HOLD)” is selected, the measurement value at the point when the HOLD/MAX button is pressed appears.
  • Page 11: Static Charge Voltage Measurement

    Four “beeps” sound to indicate that the power has turned off. Standard Static charge voltage measurement mode Eye-02 can be activated by pressing POWER button just once lightly. There is no need to press it repeatedly. Frequent unnecessary on/off operation or REMEMBER pressing by a nail may affect the life of switches and the cover sheet.
  • Page 12 If power is not turned off, the battery will be drained completely. * Eye-02 cannot return to this mode automatically, even if it is turned on again after turning off in continuous mode. For going into continuous mode, the operation described in “Continuous mode...
  • Page 13 * The LED cross mark function is adjusted so that the cross pattern irradiated by the red LED light is clearest on a flat plate placed at a measurement distance of 25 mm. This can be confirmed by facing the Eye-02 toward a piece of white paper. Measurement and cross mark If the digital numerical value blinks at [±...
  • Page 14 (1500 V) approximately for high range. * Eye-02 is calibrated for the voltage range 0 to ± 20 kV, using a 150 mm x 150 mm charged flat metal plate placed at a distance of 25 mm. For any other distance, accuracy of measurement is not guaranteed.
  • Page 15: Ion Balance Measurement

    A low voltage up to 220 V can be measured in the “Ion Balance measurement mode”. Align the Ion Balance plate to the notches on either side of the Eye-02’s sensing section, and properly mount the plate. This plate does not have a top/bottom orientation.
  • Page 16 Four “beeps” sound to indicate that the power has turned off. Standard mode for Ion Balance Measurement Eye-02 can be activated by pressing POWER button just once lightly. There is no need to press it repeatedly. Frequent unnecessary on/off REMEMBER operation or pressing by a nail may affect the life of switches and the cover sheet.
  • Page 17 If power is not turned off, the battery will be drained completely. * Eye-02 cannot return to this mode automatically, even if it is turned on again after turning off in continuous mode. For going into continuous Ion Balance measurement mode, the operation described in “Continuous mode for Ion Balance Measurement”...
  • Page 18 Ion Balance plate is not attached or not attached properly. However, the measured value will not be correct. * Eye-02 is calibrated by applying DC voltage to the Ion Balance plate directly. If the plate is attached properly to EyeE-01, the display gives a direct reading of the Ion Balance voltage.
  • Page 19: Troubleshooting

    * If the countermeasures fail or readjustment, repair or replacement is needed (except battery), do not use any more and please contact VESSEL with the product's serial number and information on the failure.
  • Page 20: Warranty

    VESSEL receives notice during the warranty period. Defective products must be returned to VESSEL Osaka Japan with proof of purchase date. And if your unit is out of warranty, VESSEL will quote repair charges necessary to ship your unit freight prepaid to where you have originally purchased.