Advertisement

Quick Links

WT1/WT2 Electronic Thermometer
User's Manual
Guangdong Biolight Meditech Co., Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WT1 and is the answer not in the manual?

Questions and answers

Summary of Contents for GUANGDONG BIOLIGHT MEDITECH WT1

  • Page 1 WT1/WT2 Electronic Thermometer User’s Manual Guangdong Biolight Meditech Co., Ltd.
  • Page 2 Document No.: Revision number: V1.0 Release time: July, 2014 Copyright © 2014 Guangdong Biolight Meditech Co., Ltd. All rights reserved. Statement Manufacturer holds the copyright of this manual, and we are also entitled to deal with this manual as confidential files. This manual is only used for operation, maintenance and service of product, someone else can not publish the manual.
  • Page 3: About This Manual

    Manufacturer's Responsibility Only under the following circumstances will manufacturer be responsible for the safety, reliability and performance of the instrument: All the installation, expansion, readjustment, renovation or repairs are conducted by the personnel certified by manufacturer. The storage condition, operation condition and electrical status of the instrument conform to the product specification.
  • Page 4: Table Of Contents

    Contents Intended Use ..........................1 Application ..........................1 Safety Information ........................1 Appearance ..........................3 Download And Install The Software ..................4 Battery Installation Steps ......................4 Using Steps ..........................5 Normal Body Temperature ......................8 Maintenance and Cleaning ......................9 Accessory and Specifications ....................
  • Page 5: Intended Use

    Intended Use The device is intended to be used for measuring and monitoring human temperature continuously via wireless signal transmission of the measuring result. Application The device is reusable and intended for measuring human temperature for persons over two years old. It can be used in hospital and at home. Safety Information Warning:...
  • Page 6 performance of the device. For this reason make sure that all external equipments operated in the vicinity of the device comply with the relevant EMC requirements. Mobile phone, X-ray equipment or MRI devices are a possible source of interference as they may emit higher levels of electromagnetic radiation.
  • Page 7: Appearance

    When the patient is the operator, please use and maintain the device according to this manual. Appearance WT1: : : : Front View: Rear View: WT2: : : : Front View:...
  • Page 8: Download And Install The Software

    Battery compartment 2.Armpit temperature measuring probe temperature measuring probe 3. Tongue Download And Install The Software 1、Software download methods: Users who use the ISO system device can log in iphone App Store, enter ”wearcare” and search for the software of “育儿宝” in the searching results. Or scan the QR code of IOS on the packing box to download.
  • Page 9: Using Steps

    3) Using the battery cover tools to install the battery cover. Tighten the battery cover according to the direction shown below: Using Steps 1) Turn on receiver and open Bluetooth; 2) Take out the temperature sensor from the packing box. Install the battery according to the above-mentioned method.
  • Page 10 When the temperature sensor connects to mobile terminal application software successfully, the Bluetooth indicator light will shine. S S S S tep tep 3: 3: 3: 3: Paste the sticker S S S S tep 4: tep 4: tep 4: tep 4: Paste the device onto armpit S S S S tep 5:...
  • Page 11 Adult should help child to wear and operate the devic Adult should help child to wear and operate the devic Adult should help child to wear and operate the devic Adult should help child to wear and operate the device. e. e. e. P P P P lease remain holding your arm tight at leas lease remain holding your arm tight at least for 5 t for 5~...
  • Page 12: Normal Body Temperature

    phenomenon at site. If there is allergy, you should immediately stop using it. Please do not re-paste the sticker if it appears fold, a new sticker is required. Skin preparation in advance is required when worn by adult. Please clean the surface of the device with 75% concentrated medical alcohol before and after use it.
  • Page 13: Maintenance And Cleaning

    f) Being in a high temperature or high humidity; g) Teething (in a young child – but no higher than 37.8℃); h) Wearing heavy clothing. Note: : : : Different measure size and different measure method may lead to different temperature value. Maintenance and Cleaning a) Clean the surface of the device with 75% concentrated medical alcohol before and after use it.
  • Page 14: Technical Specifications

    IP27:The device can prevent the solid foreign matter whose diameter is not less than 12.5mm into the equipment shell, and prevent the effects on the equipment after short term immersing. 10.3 Technical Specifications Production model WT1、WT2 WT1: 51mm×31.8mm×8.5mm Size WT2: 51mm×36.2mm×10.2mm WT1: 9.6g Weight WT2: 10.5g, The weight with tongue temperature measuring probe is 12.3g.
  • Page 15: Troubleshooting

    Connected: App software platform IOS system iPhone 4s、iPhone5、iPhone5s、iPad3+、iPad mini Android (4.3+) system Mobile phone, iPad Battery WT1: CR2032, 3V/225mAH button battery Type WT2: CR2025, 3V/170mAH button battery Work time ≥365 days (8 hours per day) Environment specifications ℃ Operating : 5℃~+40 ;...
  • Page 16: Equipment Symbols

    Type CF applied part, without defibrillation protected. Refer to this user’s manual. Symbol for the marking of electrical and electronics devices according to Directive 2002/96/EC Date of manufacture Serial number IP22 Enclosure degree of ingress protection. (WT2) IP27 Enclosure degree of ingress protection. (WT1)
  • Page 17: Appendix A Guidance And Manufacturer's Declaration Of Emc

    Appendix A Guidance and Manufacturer’s Declaration of EMC Note: : : : This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided, and this unit can be affected by portable and mobile RF communications equipment. Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit.
  • Page 18 Guidance and manufacture’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of device should assure that it is used in such an environment. Electromagnetic environment - Immunity test IEC 60601 test level Compliance level guidance...
  • Page 19 Guidance and manufacture’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. Immunity IEC 60601 Compliance Electromagnetic environment - guidance test...
  • Page 20 NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.
  • Page 21 Recommended separation distances between portable and mobile RF communications equipment and the device . The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the device as recommended below, according to the maximum output power of the communications equipment.