D-Tect 2
GJD300 Quad PIR Movement Detector

Package Contents

Package Contains:
1 x D-Tect 2
1 x Drilling template for fixing holes
1 x Allen Key
3 x 31.75mm wall plugs
3 x 31.75mm screws
2 x Spare Sliding Curtains
2 x Tamper Feet
1 x Tamper Cup
1 x Installation manual
Introduction
The D-Tect 2 is an outdoor motion detector and alarm
trigger that uses two independent passive infra-red
detectors, both of which must trigger to cause the detector
to signal an alarm. Utilising quad PIR technology, the D-Tect
2 delivers precise, reliable presence detection.
Quick Installation
1.
Mount and connect the detector following the
instructions given later in this sheet.
2.
Apply supply voltage to the unit. The detection LED
(blue) flashes three times.
3.
Wait approximately 2 to 3 minutes to allow the
detector to settle.
4.
Press the programming button once to activate
walk test mode. The detection LED is now enabled
for five minutes.
Note: The front cover must be fitted when walk
testing.
The default settings are:
Range: 20 meters
Pulse count: 1 (always set to 1 during walk test)
Detection LED: off (always enabled during Walk
Test)
'S' Lux Level: 5
Contacts:
Alarm 1: Normally Closed
Alarm 2: Normally Open
Contacts Timer: 5 (seconds)
Mounting The Unit
During installation, protect the electronics against water, as
trapped moisture can affect or damage the unit.
1.
Drill the wall to accept the two fixing screws, the
cable entry, and the tamper cup (if used). See
Figures 1 and 2.
A hole-drilling template is provided.
Note: We recommend using the tamper cup on
uneven wall surfaces.
2.
Remove the cover assembly by loosening the
locking screw using the allen key provided. The
cover hinges from the top and lifts out of the
location slot. See Figure 3.
3.
Feed standard eight-core alarm cable into the
cable entry. Bare the wires and connect to the top
PCB terminal block. See Figures 2, 4 & 5.
4.
Screw the unit to the wall ensuring that the rear
tamper pin is correctly located and that the tamper
microswitch is closed. See Figure 6.
To aid installation, two spare tamper feet are
provided. One is 1mm longer and the other is 2mm
longer than the tamper foot originally fitted. The
tamper foot is a push fit and can be removed by
carefully pulling it from the pin. See Figure 2.
5.
When the detector is aligned, connected, and
programmed to suit the installation, replace the
front cover and lock as shown. See Figure 7.

Connecting The Unit

The D-Tect 2 includes jumpers that allow you to configure
the internal end-of-line resistor values, when EOL resistors
are required. Values are 1K, 2K2, 3K3, 4K7, 5K6 and 6K8
Ω. Figure 8 shows:
1.
EOL resistor jumpers
2.
Wiring points
Alternatively, you can remove the jumpers and connect a
discrete resistor directly to the alarm or tamper outputs, as
specified by the third-party equipment.
Connections
Terminal
Label
1
A
2
S
3, 4
ALARM 1
4, 5
EOL
5, 6
TAMPER N/C
7, 8
ALARM 2
9, 10
9 -24V
Multibeam Alignment & Masking
The multifunction lens fitted to D-Tect 2 produces seven
long range beams and seven medium to short range curtain
PIR beams. The PIR circuitry detects changes in heat and
movement in the beam pattern; therefore items such as
trees, shrubs, ponds, boiler flues, and animals should be
considered when positioning the detector.
Note: The PIR sensor is more sensitive to movement
across the beams, and less sensitive to movement directly
towards or away from the beams.
The detector module is fitted with two sliding shutters to
reduce the detection angle.
The curtains are fitted to the pan and tilt module as shown
in Figure 9 (shown with primary and additional curtain
sliders fitted). Each section of the detector lens gives a
coverage pattern of approximately 10 degrees.
An additional set of curtain sliders is provided should the
beam pattern need to be narrowed even further, e.g. if the
minimum detection angle of 10 degrees is required.
When coverage exceeds the desired detection area, adjust
the module as required and mask off any beams, either
vertically or horizontally, to avoid unwanted detection.
-1-
Description
24 hour -VE Output
Dark -VE Output
Alarm relay 1
End-of-line resistors
Tamper relay, normally closed
Alarm relay 2
AC / DC Supply
04111

Advertisement

loading

Summary of Contents for GJD D-TECT 2 GJD300

  • Page 1: Package Contents

    D-Tect 2 GJD300 Quad PIR Movement Detector Package Contents Feed standard eight-core alarm cable into the cable entry. Bare the wires and connect to the top Package Contains: PCB terminal block. See Figures 2, 4 & 5. 1 x D-Tect 2 Screw the unit to the wall ensuring that the rear ●...
  • Page 2 Press 7 times to flash out your selected settings The contacts are rated at a maximum of 24V AC/DC @ 50mA. Press 8 times to reset to GJD factory settings Shaded settings are factory defaults 04111...
  • Page 3: Specifications

    Using all five outputs (including Accessories Cable < 200m tamper) – 12 core 7/0.2mm GJD is able to supply the following accessories to aid Using all five outputs (including installation: Cable < 500m tamper) – 12 core 16/0.2mm GJD303...
  • Page 4 Optional for Tamper Cup Cable Holes Template 12/ 24V AC Supply 0V Supply 12VDC Supply To GJD Lighting Controller Alarm Output 2 Multiplexer, PTZ Dome Alarm Output 1 DVR, Etc. Normally Closed Multiplexer, PTZ Dome DVR, Etc. Tamper Circuit Front + Rear...
  • Page 5 Programming LED Programming Button 04111...
  • Page 6 Engineer Notes GJD Manufacturing Limited Unit 2 Birch Industrial Estate, Whittle Lane, Heywood, Lancashire, OL10 2SX Sales: +44 (0) 1706 363 998 Technical: +44 (0) 1706 363 990 Fax: +44 (0) 1706 363 991 Email: info@gjd.co.uk Web: www.gjd.co.uk 04111...
  • Page 7 Engineer Notes GJD Manufacturing Limited Unit 2 Birch Industrial Estate, Whittle Lane, Heywood, Lancashire, OL10 2SX Sales: +44 (0) 1706 363 998 Technical: +44 (0) 1706 363 990 Fax: +44 (0) 1706 363 991 Email: info@gjd.co.uk Web: www.gjd.co.uk 04111...
  • Page 8 Engineer Notes GJD Manufacturing Limited Unit 2 Birch Industrial Estate, Whittle Lane, Heywood, Lancashire, OL10 2SX Sales: +44 (0) 1706 363 998 Technical: +44 (0) 1706 363 990 Fax: +44 (0) 1706 363 991 Email: info@gjd.co.uk Web: www.gjd.co.uk 04111...

This manual is also suitable for:

D-tect 2Gjd300