Download Print this page

Advertisement

Quick Links

Pendant stations
P02 - PTRM - P03 - PL - PLB - DC16 - DC30 - TLP Series
Table of contents
Pendant stations for small hoist application for control circuits,
in both single or double row version for control circuits and direct switching
General characteristics
P02 - PTRM Series pendant stations
for small hoist applications
P03 Series pendant stations
for small hoist applications
Single row PL Series pendant stations
for control circuits
Double row PLB Series pendant stations
for control circuits
PL - PLB Series - Pendant stations
for control circuits - Enclosures pendant
stations single products and Accessories
power circuits, for tail lift control.
Table of contents
PL - PLB Series pendant stations for
pag. 12
control circuits, Configuration and Symbols
pag. 13
PL - PLB Series pendant stations
for control circuits, Assembly
pag. 14
DC16 Series pendant stations
for small hoist applications
pag. 16
DC30 Series pendant stations
for direct switching power circuits
pag. 17
Pendant stations for control circuits
and power circuits - Schemes
pag. 18
TLP light Series - Pendant stations
General and electricals characteristics
TE C HN O- LI FTI N G EQ UI PM E N T
pag. 20
pag. 22
pag. 24
pag. 25
pag. 27
pag. 28
pag. 31
11

Advertisement

loading

Summary of Contents for CGG P02

  • Page 1 Pendant stations P02 - PTRM - P03 - PL - PLB - DC16 - DC30 - TLP Series Table of contents TE C HN O- LI FTI N G EQ UI PM E N T Pendant stations for small hoist application for control circuits, in both single or double row version for control circuits and direct switching power circuits, for tail lift control.
  • Page 2 Pendant stations P02 - PTRM - P03 - PL - PLB - DC16 - DC30 - TLP Series Characteristics GENERAL CHARACTERISTICS Giovenzana International Company, leader in lifting equipment control, made a wide range of standard products for all installation requirements with actual specification and safety guidelines.
  • Page 3 Pendant stations P02-PTRM Series pendant stations for small hoist applications IP65 TE C HN O- L I FTI N G EQ UI PM E N T 2 directions mechanically interlocked ENGRAVING DESCRIPTION CODE WEIGHT gr DIMENSIONS For single speed motor control Ø7...
  • Page 4 Pendant stations P03 Series pendant stations for small hoist applications IP65 2 directions mechanically interlocked ENGRAVING DESCRIPTION CODE WEIGHT gr DIMENSIONS For single speed motor control n° 1 emergency stop EN ISO 13850 mushroom Ø 30 turn to release with: P03.1 n°...
  • Page 5 Pendant stations P02-P03 Series pendant stations for small hoist applications Mounting drawing TE C HN O- L I FTI N G E QUI PM ENT P02 SERIES P02 Pendant station P03 SERIES P03 Pendant station...
  • Page 6 Pendant stations PL Series pendant stations for control circuits Single row IP65 N° PUSH BUTTONS DESCRIPTION CODE WEIGHT gr For single-speed motor control 4 mechanically interlocked between pairs PL05 + n° 1 emergency stop EN ISO 13850 mushroom Ø 30 turn to release For two-speeds motor control N°...
  • Page 7 Pendant stations PLB Series pendant stations for control circuits Double row IP65 TE C HN O- LI FTI N G EQ UI PM E N T N° PUSH BUTTONS DESCRIPTION CODE WEIGHT gr For single-speed motor control 2 Mechanically interlocked between pairs + 1 Start/Allarm PLB04 + N°...
  • Page 8 Pendant stations PL-PLB Series pendant stations for control circuits IP65 Enclosures PL - SINGLE ROW DIMENSIONS DESCRIPTION CABLE ENTRY Ø CODE WEIGH gr MIN. PACK QTY. Pendant station PL05K with 5 holes 7...18 Pendant station PL07K with 7 holes Pendant station PLO8K with 8 holes N°...
  • Page 9 PLO11001 3 HOLES PLOO3002 BOTTOM PLO11002 See pag. 21 CABLE CLAMP LEVER CABLE SLEEVE VERSION CODE P02 - PTRM 12906011 For cable Ø 7...14 P03 - PL05 12906006 For cable Ø 7...18 PL07...PL12 12906004 PLB04-PLB06 For cable Ø 9...21 PLB08-PLB14...
  • Page 10 Pendant stations PL-PLB Series for control and direct switching power circuit Composition PL07 PL08 PL08D2 PL08D4 PL08D6 PL10 PL12 PL SERIES START START START START START START STOP STANDARD VERSIONS PL05 PL05D2 PL05D4 ALARM ALARM ALARM ALARM ALARM ALARM LIFT STOP STOP STOP...
  • Page 11 Pendant stations P02-P03-PL-PLB Series for auxiliares power circuits Engravings push button TE C HN O- LI FTI N G EQ UI PM E N T PUSH BUTTONS WITH SIMBOLS FEM 9.941 Standard DOWN FORWARD REVERSE LEFT RIGHT SPIN LEFT SPIN RIGHT...
  • Page 12 PL Series for auxiliary controls and direct switching power circuits Assembly PL SERIES STANDARD VERSIONS PL - P02 - P03 Single row Note: For execution "empty enclosures in kit", the parts "yellow underline" 07, 09, 10 and 11 will must be order separatly.
  • Page 13 Pendant stations PLB Series for auxiliary controls and direct switching power circuits Assembly TE C HN O- LI FTI N G EQ UI PM E N T PLB SERIES STANDARD VERSIONS PLB Double row standard versions Note - For execution" empty enclosures in kit", the parts "yellow underline"...
  • Page 14 Pendant stations DC16 Series pendant station for power circuits IP65 Direct switching GENERAL CHARACTERISTICS Protection rating according to IEC/EN 60947-5-1 SCHEME OF DIRECT SWITCHES FOR MONOPHASE Double insulated ABS POWER 1KW Enclosures IP65 IEC/EN60529 PS Push button up Contact blocks IP20 with screw connection PD Push button down 2 Directions mechanically interlocked I Stroke end switch up...
  • Page 15 Pendant stations DC30 Series pendant station for power circuits IP65 Direct switching TE C HN O- LI FTI N G EQ UI PM E N T GENERAL CHARACTERISTICS Protection rating according to IEC/EN 60947-5-1 Push buttons with laserable engraving Double insulated ABS Cable entry with M25 cable clamp Enclosures IP65 IEC/EN60529 Rated insulation voltage Ui 500V...
  • Page 16 Pendant stations DC30 Series for power circuit IP65 Direct switching - DC16-DC30 Accessories 2 directions ENGRAVING DESCRIPTION CODE WEIGTH gr DIMENSIONS mechanically interlocked FOR TWO SPEEDS MOTOR POWER CIRCUIT n°1 Emergency stop Mushroom Ø 30 turn to release with: DC30D2 n°...
  • Page 17 Pendant stations For auxiliary power circuit Schemes TE C HN O- L IF TI N G E Q UI PM EN T DROWINGS EXAMPLES POWER CIRCUITS For single speed, 2 reversing motor. For single speed, 2 reversing motor. Contact block 3NO+1NC Contact block 4NO LINE MONO-PHASE...
  • Page 18 Pendant stations TLP Light Series IP65 GENERAL CHARACTERISTIC Lifting platform and tails lift application Two directions mechanically interlocked In conformity to IEC/EN 60947-5-1, UNI EN 1570 Push buttons laser engraving Box in thermoplastic - Shock and heat resistance Pendant or solid fixing IP65 Double insulation IEC/EN60529 Skin stop cable gland M20 Contact blocks IP20 with spring connection...
  • Page 19 Pendant stations TLP Light Series IP65 TE C HN O- LI FTI N G EQ UI PM E N T DESCRIPTION ENGRAVING SCHEMI CODE WEIGHT gr DIMENSIONS n° 2 push buttons TLP2 up and down 12.5 n°1 Emergency 31.5 stop Ø30 twist to release with 1NC contact x button...
  • Page 20 Pendant stations TLP Light Series IP65 DESCRIPTION ENGRAVING SCHEMS CODE WEIGHT gr DIMENSIONS n°1 Emergency 31.5 stop Ø30 twist to release with 1NO for contact block TLP4.A n°3 push buttons up-common-down with 1NO for contact block 12.5 n°1 key switch with 1NO 31.5 20.5...
  • Page 21 Pendant stations P02 - PTRM - P03 - DC16 - PL - DC30 - TLP Series General and electrical characteristics TE C HN O- L IF TI N G E Q UI PM EN T P02 - PTRM - P03...

This manual is also suitable for:

PlPlbDc16TlpDc30Ptrm ... Show all