Empire Comfort Systems DVC-35SPP Installation Instructions And Owner's Manual page 2

Fan type direct vent wall furnace
Table of Contents

Advertisement

Introduction
Always consult your local Building Department regarding
regulations, codes or ordinances which apply to the installa-
tion of a direct vent wall furnace.
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card
supplied with furnace.
3. Installer should show owner how to start and operate
furnace and thermostat.
Warning:
Any change to this furnace or its control can be dan-
gerous. This is a heating appliance and any panel, door
or guard removed for servicing an appliance must be
replaced prior to operating the appliance.
General Information
This furnace is design certified in accordance with American
National Standard/CSA Standard Z21.86b-1998 and CSA
2.32b-M98 by the American Gas Association and Canadian
Gas Association, as a fan type direct vent wall furnace to be
installed according to these instructions.
Any alteration of the original design, installed other than
as shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
Important
All correspondence should refer to complete Model No.,
Serial No. and type of gas.
Notice: During initial firing of this unit, its paint will bake out
and smoke will occur. To prevent triggering of smoke alarms,
ventilate the room in which the unit is installed.
DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANELS INSTALLED
• Due to high temperatures the appliance should be lo-
cated out of traffic and away from furniture and draper-
ies.
• Children and adults should be alerted to the hazards of
high surface temperatures and should stay away to avoid
burns or clothing ignition.
• Young children should be carefully supervised when
they are in the same room as the appliance.
• Clothing or other flammable material should not be
placed on or near the appliance.
• Any safety screen or guard removed for servicing an
appliance must be replaced prior to operating the appli-
ance.
• Keep burner and control compartment clean.
• Vent cap hot while furnace is in operation.
• Installation and repair should be done by a QUALI-
FIED SERVICE PERSON. The appliance should be
inspected before use and at least annually by a
qualified service person. More frequent cleaning
may be required due to excessive lint from carpeting,
bedding materials, etc. It is imperative that control
Page 2
Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other
combustible material other than wood flooring the appliance
shall be installed on a metal or wood panel extending the full
width and depth of the appliance.
The base referred to above does not mean the fire-proof base
as used on wood stoves. The protection is for rugs that are
extremely thick and light colored tile.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be in-
stalled so that all burners and burner ignition devices are
located not less than 18" (45.7cm) above the floor.
Such equipment shall be located, or protected, so it is not
subject to physical damage by a moving vehicle.
Specifications
THIS IS A HEATING APPLIANCE
• DO NOT put anything around the furnace that will
• DO keep the appliance area clear and free from combus-
• DO examine venting system periodically and replace
• DO make a periodic visual check of pilot and burners.
• CAUTION: Pilot hole cover must be kept tightly closed
• DO NOT use this heater if any part has been under water.
Model
DVC-35SPP
Input BTU/HR
35,000 (10.3)
Height
72
" (184.2cm)
1/2
Width
14
" (358mm)
1/8
Depth
10
" (264mm)
3/8
Gas Inlet
" Pipe (13mm)
1/2
CFM
Accessories
SOR-1
Register, Side Outlet
SOK-1
Side Outlet Kit, 10" (25.4cm) Boot Assembly with Register
DV-822
Vinyl Siding Vent Kit
compartments, burners and circulating air passageways
of the appliance be kept clean.
obstruct the flow of combustion and ventilation air.
tible material, gasoline and other flammable vapors and
liquids.
damaged parts.
Clean and replace damaged parts.
during operation.
Immediately call a qualified service technician to inspect
the heater and to replace any part of the control system
and any gas control which has been under water.
IMPORTANT: This furnace has a washable perma-
nent type filter which should be cleaned at least once
per year before the heating season. For dirty or high
use areas more frequent cleaning is required.
DVC-35IP
35,000 (10.3)
72
" (184.2cm)
1/2
14
" (358mm)
1/8
10
" (264mm)
3/8
" Pipe (13mm)
1/2
275
275
.
R-3122

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvc-35ip

Table of Contents