ADC Digivance ICS 800 Installation Instructions Manual

Indoor coverage solution 800 and 1900 mhz digital remote unit

Advertisement

Quick Links

Content
INTRODUCTION............................................................................2
1
DESCRIPTION ........................................................................3
1.1
1.2
1.3
2
INSTALLATION PROCEDURE ..............................................................7
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
3
CUSTOMER INFORMATION AND ASSISTANCE .................................................. 22
1185527 Rev A
Digivance
800 and 1900 MHz Digital Remote Unit
Digital Remote Unit ..............................................................3
Antenna Options ................................................................5
AC/DC Power Converter............................................................6
Tools and Materials ..............................................................7
Unpacking and Inspection ..........................................................8
Frequency Band Selection (1900 DRU Only) .............................................8
DRU Mounting Procedure ..........................................................9
Antenna Mounting Procedure....................................................... 10
Antenna Connection ............................................................. 17
Optical Connection.............................................................. 18
DC Power Connection ............................................................ 19
Indoor Coverage Solution
Installation Instructions
Digital Remote Unit
ADCP-75-112 • • • • Issue 3 • • • • August 2001
16449-A
Page 1
© 2001, ADC Telecommunications, Inc.
Page

Advertisement

Table of Contents
loading

Summary of Contents for ADC Digivance ICS 800

  • Page 1: Table Of Contents

    DRU Mounting Procedure ............9 Antenna Mounting Procedure............10 Antenna Connection ............. 17 Optical Connection.............. 18 DC Power Connection ............19 CUSTOMER INFORMATION AND ASSISTANCE ..........22 16449-A Digital Remote Unit 1185527 Rev A Page 1 © 2001, ADC Telecommunications, Inc.
  • Page 2: Introduction

    Related Publications Listed below are related manuals and their publication numbers. Copies of these publications can be ordered by contacting the ADC Technical Assistance Center at 1-800-366-3891 extension 63475 (in U.S.A. or Canada) or 952-946-3475 (outside U.S.A. and Canada). Title...
  • Page 3: Description

    The RF signal interface between the DRU and the cellular users is provided through an external antenna connected to an SMA connector. The antenna may be ordered separately from ADC. Several types of antennas with various patterns are available. Non-ADC antennas may also be used with the DRU to meet various application requirements.
  • Page 4 Used for connecting the antenna coaxial connector (female) cable lead. Note: A detailed description of DEU LED operation is provided in the Digivance ICS 800 and 1900 MHz Systems Installation and Operation Manual (ADCP-75-110) Page 4 © 2001, ADC Telecommunications, Inc.
  • Page 5: Antenna Options

    ADCP-75-112 • Issue 3 • August 2001 1.2 Antenna Options Various antennas, shown in Figures 3 and 4, are available from ADC for use with the DRU. All antennas include a 6 foot (1.8 m) long 50-ohm coaxial cable (equipped with SMA male connector) for connection to the DRU.
  • Page 6: Ac/Dc Power Converter

    RJ-45 male connector. The converter is powered by 120/240 Vac (50 or 60 Hz) power which is supplied though a standard three-conductor AC power cord. The 120 Vac power cord is 6 feet (1.8 m) long and is provided with the converter. Page 6 © 2001, ADC Telecommunications, Inc.
  • Page 7: Installation Procedure

    (if used). Installation of the DRU may proceed separately from the installation of the DHU and the DEU. When the installation of the DRU is completed, refer to the Digivance ICS 800 and 1900 MHz Systems Installation and Operation Manual (ADCP-75- 110) for the system turn-up and test procedures.
  • Page 8: Unpacking And Inspection

    1. Open the shipping carton and carefully unpack the DRU from the protective packing material. 2. Check the DRU for broken or missing parts. If there are any damages, contact ADC Telecommunications (see Customer Information and Assistance section) for an RMA (Return Material Authorization) and to reorder if replacement is required.
  • Page 9: Dru Mounting Procedure

    (if pass-through holes are required). 5. Place the DRU in position for mounting and then install the fasteners as shown in Figure 7. 6. Securely tighten each fastener. Page 9 © 2001, ADC Telecommunications, Inc.
  • Page 10: Antenna Mounting Procedure

    Figure 7. DRU Mounting 2.5 Antenna Mounting Procedure Various types of antennas are available from ADC for use with the DRU. All antennas include a 6-foot (1.8 m) long 50-ohm coaxial cable for connection to the DRU. Each type of antenna provides a specific coverage pattern in order to accommodate the shape of the area where coverage is required.
  • Page 11: 800 And 1900 Mhz Ceiling-Mount Omni Directional Antenna Installation - Subsection

    ANTENNAS MUST BE INSTALLED TO PROVIDE AT THREADED SPACER LEAST 20 CENTIMETERS OF SEPARATION FROM (REMOVE IF NOT NEEDED) ALL PERSONS PER FCC 47 CFR PART 2.1091. 16244-B Figure 8. 800 and 1900 MHz Ceiling-Mount Omni Directional Antenna Installation Page 11 © 2001, ADC Telecommunications, Inc.
  • Page 12: 800 Mhz Ceiling-Mount Hallway Antenna Installation - Subsection

    LEAST 20 CENTIMETERS OF SEPARATION FROM ALL PERSONS PER FCC 47 CFR PART 2.1091. 16245-B ORIENT ANTENNA SO FLAT SIDES ARE PERPENDICULAR WITH HALLWAY WALLS Figure 9. 800 MHz Ceiling-Mount Hallway Antenna Installation Page 12 © 2001, ADC Telecommunications, Inc.
  • Page 13: 800 Mhz 70º Directional Panel Antenna Installation - Subsection

    SIDE OF ANTENNA IS POINTING UP WHEN ANTENNA IS MOUNTED 5/8-INCH (16 mm) HOLE FOR ANTENNA CABLE USE APPROPRIATE FASTENERS FOR WALL SURFACE 16246-B Figure 10. 800 MHz 70º Directional Panel Antenna Installation Page 13 © 2001, ADC Telecommunications, Inc.
  • Page 14: 800 Mhz 90º Directional Panel Antenna Installation - Subsection

    5/8-INCH (16 mm) HOLE FOR ANTENNA CABLE HANDLE MAKE SURE ARROW ON REAR SIDE OF ANTENNA IS POINTING UP WHEN ANTENNA IS MOUNTED 16247-B Figure 11. 800 MHz 90º Directional Panel Antenna Installation Page 14 © 2001, ADC Telecommunications, Inc.
  • Page 15: 1900 Mhz Ceiling-Mount Hallway Antenna Installation - Subsection

    ALL PERSONS PER FCC 47 CFR PART 2.1091. CONNECTOR CONNECTOR HARD CEILING MOUNT CEILING TILE RAIL MOUNT ORIENT ANTENNA SO FLAT SIDES ARE PERPENDICULAR WITH HALLWAY WALLS 16708-B Figure 12. 1900 MHz Ceiling-Mount Hallway Antenna Installation Page 15 © 2001, ADC Telecommunications, Inc.
  • Page 16: 1900 Mhz 90º Directional Panel Antenna Wall-Mount Installation - Subsection

    FOR ANTENNA CABLE MAKE SURE ARROW ON REAR SIDE OF ANTENNA IS POINTING UP WHEN ANTENNA IS MOUNTED USE APPROPRIATE FASTENERS FOR WALL SURFACE 16740-A Figure 13. 1900 MHz 90º Directional Panel Antenna Wall-Mount Installation Page 16 © 2001, ADC Telecommunications, Inc.
  • Page 17: 1900 Mhz 90º Directional Panel Antenna Corner-Mount Installation - Subsection

    ANTENNAS MUST BE INSTALLED TO PROVIDE AT LEAST 20 CENTIMETERS OF SEPARATION FROM ALL PERSONS PER FCC 47 CFR PART 2.1091. 16817-A Figure 14. 1900 MHz 90º Directional Panel Antenna Corner Mount Installation Page 17 © 2001, ADC Telecommunications, Inc.
  • Page 18: Antenna Connection

    This practice also prevents dirt particles from entering the transceiver or connector. 1. Locate the forward and reverse path optical links that were routed to the DRU from the DHU or DEU. Page 18 © 2001, ADC Telecommunications, Inc.
  • Page 19: Dc Power Connection

    Note: The procedures for routing the forward and reverse path optical links from the DHU or DEU to the DRU are covered in either the Digivance ICS 800 and 1900 MHz Systems Installation and Operation Manual (ADCP-75-110), which is provided with the DHU, or the Digivance ICS Digital Expansion Unit Installation Instructions (ADCP-75- 111), which is provided with the DEU.
  • Page 20 3. Dress and secure the power cable at the DRU per standard industry practice. 4. When the installation of the DRU is completed, refer to Section 4 of the Digivance ICS 800 and 1900 MHz Systems Installation and Operation Manual (ADCP-75-110) for the system turn-up and test procedures.
  • Page 21 7. Dress and secure both power cables per standard industry practice. 8. When the installation of the DRU is completed, refer to Section 4 of the Digivance ICS 800 and 1900 MHz Systems Installation and Operation Manual (ADCP-75-110) for the system turn-up and test procedures.
  • Page 22: Customer Information And Assistance

    U.S.A. Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.

This manual is also suitable for:

Digivance ics 1900

Table of Contents