Sliding Gate Operator
User's Manual
PY-500ACU/PY-800ACU
soft start&slow stop

Advertisement

loading

Summary of Contents for ZEC Automation PY-800ACU

  • Page 1 Sliding Gate Operator User's Manual PY-500ACU/PY-800ACU soft start&slow stop...
  • Page 2 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR 1. Products introduction Please read the instructions carefully before proceeding. MCU is supplied to control the gate operator. Keypad / single button interface. Photo beam safety beam interface. User can select Auto-close function. Manual key release design for emergency purposes.
  • Page 3 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR Output torque 14N·m Limit switch Spring limit switch or Magnetic limit switch Noise ≤56dB Duty cycle S2, 15 minutes extra remote control Environmental temperature -20°C~+50°C Gate Move speed 13m/min 15m/min DKC800AC/DKC800ACU Type PY-800ACU PY-800ACT Power supply...
  • Page 4 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR 4. Mechanical Installation will handle gate weighting up to 500 PY-500ACU/PY-800ACU kg/800kg and up to 8m/12m if the proper installation procedures have been followed. gate operator operates by forcing a drive rack by a PY-500ACU drive gear.
  • Page 5 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR In order to protect the cable, use PVC conduit for low voltage power cable and control wires. Conduit must be preset into the concrete when it is poured. Wires within the conduit shall be located or protected so that no damage can result from contact with any rough or sharp part.
  • Page 6 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR Magnetic limit switch Fig.2 Anchors (see Fig.2) You can use anchor bolts, anchors, washers and nuts. These anchors must be set into the concrete when it is poured or you can use wedge anchors to fasten the operator.
  • Page 7 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR Fig.3 Installation of Rack  Fix the three nuts (in the same package with rack) on the rack element.  Lay the first piece of rack on the gear and weld the first nut on the gate.
  • Page 8 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR Fig.4 5. Adjustment Spring limit switch  To ensure safety, it is recommended to install limit switches at both ends of the gate to prevent the gate from sliding out of the rails. The rails must be installed horizontally.
  • Page 9 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR of limit switch and blocks are used to control the position of the gate. Release the gear with the key and push the sliding gate manually  to pre-determine the position, fix the block to the rack and lock the gear by push up the release bar.
  • Page 10 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR Magnetic limit switch Fig.5 Spring limit switch Magnetic limit switch Fig.6...
  • Page 11 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR Manual operation In case of power failure use key unlock the lock and pull down the release bar about 90 degree to open or close gate manually, use the release key as follow:  Fit the supplied key in the lock.
  • Page 12 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR Make sure that the power is OFF before making any electrical connections. Remove the cover, perform the wiring (See Fig.8 and wiring notes for control board) and replace the cover again. Learn button Open limit Limit...
  • Page 13 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR PY-500ACU/PY-800ACU AC110V b. Caution light: connect caution light wire to L and N of LAMP(terminal J4) PY-500ACU/PY-800ACU:AC 220V PY-500ACU/PY-800ACU:AC110V c. Output power supply: 12VDC(7 of J5), COM (9 of J5), I.R. (8 of J5 is N.C Infrared) If the infrared beam is interrupted during closing, the gate will reverse and open immediately.
  • Page 14 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR to ‘1 (OPEN)’ of terminal J2, connect close wire of switch to ‘2 (CLOSE)’, connect stop wire of switch to ‘3(STOP)’, connect common wire of switch to ‘4(COM)’. terminal J2 terminal J2 Keypad Stop Open Single-button...
  • Page 15 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR and C (capacitor). If the door move direction is wrong, please change the MOT1 and MOT2 of motor, and change the block of Magnetic limit switch) . limit ( terminal J4 Terminal J6 Capacitor Mot1 Mot2...
  • Page 16 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR the door will auto closed after the car through the loop. If the car stops on the loop the door can’t close. 7. Tuning and operation a. Adjust the Adjustable resistance (see Fig.8) VR1: For motor working total time adjustment.
  • Page 17 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR has been programmed, the gate will close, stop, open or stop cycle. Remote Pedestrian button: After you learn the button 4, you press the remote button 4 the door will open 1 meter when the door is closed.
  • Page 18 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR exchanging wires ‘MOT1’ and ‘MOT2’, ‘Open limit(13 of J5)’ and ‘Close limit(11 of J5)’. 8. Programming Process Adjust the DIP switch(see Fig13B and table 1) Fig. 13A Fig.13B...
  • Page 19 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR Fig. 13C Fig. 13D Table 1: DIP switch adjust DIP-switch Function SET No soft start mode (see Fig.13A) Soft start mode(need to power on reset). (see Fig.13A) N.C. limit switch(spring limit) (see Fig.13B) N.O. limit switch(magnetic limit) When the 3 and 4 all OFF, the Auto-close function is disable.
  • Page 20 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR time is near 12 Sec. when the 3 ON and the 4 is OFF auto-close time is near 24 sec. when the 3 and the 4 is all in ON position, the auto-close time (see Fig.13D) is near 36 sec.
  • Page 21 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR  Open priority: The gate will return to open if press ‘OPEN’ button of external button switch during closing. Limit switch: The switch is used to accurately stop the gate in  the opened and closed positions.
  • Page 22: Troubleshooting

    PY-500ACU/PY-800ACU SLIDING GATE OPERATOR connected the LED will light. k) LED 12 indicate the ‘Open limit switch’ status, if the switch is connected the LED will light. All these LED position see the Fig.8 10. Maintenance  Check the door once a month. The door should be carefully checked for balance.
  • Page 23 PY-500ACU/PY-800ACU SLIDING GATE OPERATOR Replace 1. Battery level may be Remote battery inside transmitter does transmitter. 2. Transmitter code is not work. Reprogram lost transmitter. The transmitter operating Battery level may be Replace battery. distance is too low. short. 11. Packing list...

This manual is also suitable for: