Wiring Diagram
Wiring Diagram
ZONE 2
3K3
ZONE 4
6K8
ZONE 3
6K8
ZONE 1
RELAY
3K3
COM
INPUT
EOLR
INPUT
EOLR
COM
TAMPER
Free Install Tool
Download the
TechTools App for
More Info: Page 12
+12V
GND
ZONE 1
COM
ZONE 2
R 2 NO
bit.ly/multicom
R 1 NO
R COM
TAMPER
Setup Guide
user app for your
bit.ly/alinkguide
MULTICOM 3G
QUICK START &
WIRING DIAGRAM
smart phones.
AlarmLINK
Setup the end
customer.
Download
Full Manual
bit.ly/mc3gman
V1.7

Advertisement

loading
Need help?

Need help?

Do you have a question about the MC3G and is the answer not in the manual?

Questions and answers

Summary of Contents for MULTICOM MC3G

  • Page 1: Quick Start

    Wiring Diagram Wiring Diagram ZONE 2 MULTICOM 3G Free Install Tool Download the QUICK START & ZONE 4 TechTools App for WIRING DIAGRAM smart phones. ZONE 3 More Info: Page 12 +12V ZONE 1 RELAY ZONE 1 ZONE 2 INPUT...
  • Page 2 Internet, you should be aware that your alarm system may not function as MC3G to mount or place the box in the desired effectively as with traditional telephone systems. For example, if your VoIP location.
  • Page 3 Limited Warranty Statement Quick Start Guide Multicom does not install or connect the products, which may be used in conjunction with other products not manufactured by Multicom; therefore Drill Bit Size - 7mm Multicom cannot guarantee or warrant the performance of the security OPTION 2 system.
  • Page 4 300mA, connect to a Suretek MCPS12 power Multicom will not be responsible for any custom fees, or taxes that may be supply (available separately) or a fi xed 12Vdc due. For those jurisdictions where the legal minimum warranty exceeds power supply (>300mA).
  • Page 5: Limited Warranty Statement

    Connect the “PANEL” connection on the MC3G be free from defects in material and workmanship, under normal use, for a period of twelve (12) months, or twenty four (24) months if the Multicom to the “PSTN” connection on the alarm panel product is installed by a ‘Certifi...
  • Page 6 PSTN/COMM fail. Connect the alarm panel’s relay output to one of the MC3G’s zone inputs then ensure that the zone is enabled. See Option 30. If not using Zone 2 please seal the zone...
  • Page 7 MC3G relays is programmed to “COMM’s fail event” (Relay 1 is programmed to this by default). Connect the chosen MC3G relay output to one of the Alarm Panel’s zone inputs. It is recommended that the zone on the alarm panel be a 24 hour audible input.
  • Page 8 Quick Start Guide Multicom Programming Methods 6. Connect to the PSTN (Optional) Log On to the Device On MC3G Upload/Download hardware 1. Click ‘Panels’ on the main screen PSTN is unavailable and this step should be skipped. 2. Enter the ‘Panel ID’ or scan the device barcode (Printed on top of Device &...
  • Page 9 TechCode and give it to your employer(s) who will in turn give you permission to work on their The second MC3G relay (R2 NO) can be panels. (Employers may need to call 1300 confi gured to arm/disarm the alarm panel or 65 44 33 to confi...
  • Page 10 Quick Start Guide 8. Test Signal Strength & Device 9. Activate the Device Power up the MC3G. The logo LED’s will act To enable this MC3G on the Surepoll as a signal strength indicator for the Active SIM network log into it via TechTools and visit the ‘Commission’...