These instructions are an integral part of the unit and must always be kept in the vicinity of the installation location or on the unit itself. This operating manual is a translation of the German original. Subject to modifications; no liability accepted for errors or misprints! Made by REMKO...
Modification of units and components nected from the equipment. ■ supplied by REMKO is not permitted and can cause malfunctions. To preclude any danger from the unit, ■ take appropriate hazard-prevention...
Intended use Environmental pro- tection and recycling The fresh water station was developed for use by regenerative heating appli- Disposing of packaging ances, particularly for heat pumps. The domestic hot water is only heated All products are packed for transport when there is demand, via a stainless in environmentally friendly materials.
REMKO FRESH WATER STATION through the secondary side to be heated not susceptible to the formation of scale to domestic hot water temperature. - even in very hard water areas. A mixing valve allows the temperature A customer-supplied circulation pump of the domestic hot water to be limited can be connected.
Installation To perform the installation, proceed as follows: Select the most suitable place to install the fresh water station. Please ensure that the area is appropriately accessible for installtion and possible servicing work (clearance of approx. 50 cm to the front and sides). Seal the two supplied reducing double nipples 6/4"...
REMKO FRESH WATER STATION Put on the cover and screw into place. Plug the mains plug into a suitable Schuko socket. Installation orientation of the flow switch Orientation for installation: G 3/4” oder 1” G 3/4“ or 1“ When fitting the flow switch, ensure that the hex nut is pointing upwards, like in the diagram.
Electrical connection The fresh water station is fully wired in NOTE the factory and is supplied ready to plug in. All you need is a 230 V/50 Hz socket In order to avoid the circulation pump from running dry, the fresh with a 10 A or 16 A fuse.
Supplemental note with regard to the on-site drinking water circulation system In rare cases, it can happen that the pressure loss in the circulation line is relatively large and that, as a consequence, the circulation pump's output will not be adequate to overcome the fresh water station flow monitor's activation threshold of 1.5 l/min.
REMKO FRESH WATER STATION Service notes If the circulating pump is replaced or the plate heat exchanger must be removed for cleaning purposes, it is possible to do so without first emptying the buffer tank if you proceed as follows: 1.
Exploded view Spare parts list Description BG 500 BG 800/1000 1178B5000 1179B5000 from serial number Mixing valve, upper section 1120100 1120100 Mixing valve, lower section 1120101 1120101 Ball valve, 1" with coupler 1120102 1120102 Ball valve, hot water 1120103 1120103...
REMKO FRESH WATER STATION Technical data Series BG 500 BG 800/1000 Inches 3/4 (19.05) 3/4 (19.05) Cold water connection (mm) internal thread internal thread Inches 3/4 (19.05) 3/4 (19.05) Drinking water connection (mm) internal thread internal thread Max. operating pressure, heating water Max.