you get to step 2 do not enter the second accessory command, instead select the
DELAY command.
To access delay commands:
Press "ENTER" at the following prompt to see more command options:
You will see more commands.
Press "ENTER" again to see the "OTHER CMDS" Prompt.
Press "5" to be presented with "OTHER" commands that are available
Press "1" to use the DELAY command.
We want a 1 second delay. The 4 second interval will be too long so press "2" to
select the ¼ second interval delay command.
Press "4" followed by "ENTER" to introduce a 1 second delay (4 x ¼ = 1).
Note that the step number is now 3. The delay command uses up one command step.
Proceed to program the second accessory command as normal. When input 3 is
grounded the first accessory command will be sent immediately. After a 1 second
delay the second accessory command will be sent.
NOTE: The Mini Panel will do nothing while it is performing a delay. If you use a very
long delay activity on other inputs may be missed. With the short delays
Last revised: 9 December 2008
INP: 03
STEP: 2
1=ACCY 2=MACRO
INP: 01
STEP: 2
3=LOCO 4=SIGNAL
INP: 01
STEP: 2
5=OTHER CMDS
SELECT CMD GROUP
1=DELAYS 2=WAIT
SELECT INTERVAL
1=4SEC 2=1/4SEC
SELECT CMD GROUP
NUM 1/4 SEC: 00
INP: 03
STEP: 3
1=ACCY 2=MACRO