7. Remove six screws securing the PCU shield.
8. While you push the stopper to release the PCU
shield, take the PCU shield out of the printer.
Samsung Electronics
9. Unplug all connectors from the PCU shield, and
remove the shield.
To replace HV terminals :
Remove the terminals.
Stopper
Note: When you replace with new ones, be careful
Disassembly and Reassembly
that they are inserted in place.
HV terminals
4-13