Analytical Industries Palm Co Instructions For Use Manual

Carbon monoxide analyzer

Advertisement

Quick Links

Assembled under a certified
Quality Management System
MDD/93/42 EEC, Annex II

ISO 13485:2003

ISO 9001:2008

Copyright © 11/16 All Rights Reserved
Analytical Industries Inc.
2855 Metropolitan, Pomona, CA 91767 USA.
Tel: 909-392-6900, Fax: 909-392-3665
Email: Diveaii@aii1.com, Web: www.aii1.com
This manual may not be reproduced in whole or in part with-
out the prior written consent of Analytical Industries Inc.
Palm CO
Palm CO
Palm CO
Carbon
Carbon
Carbon
Monoxide
Monoxide
Monoxide
Analyzer
Analyzer
Analyzer
Instructions
for Use

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Palm Co and is the answer not in the manual?

Questions and answers

Summary of Contents for Analytical Industries Palm Co

  • Page 1 2855 Metropolitan, Pomona, CA 91767 USA. Monoxide Monoxide Monoxide Tel: 909-392-6900, Fax: 909-392-3665 Email: Diveaii@aii1.com, Web: www.aii1.com Analyzer Analyzer Analyzer This manual may not be reproduced in whole or in part with- out the prior written consent of Analytical Industries Inc.
  • Page 2: Table Of Contents

    1.1 Indications for Use Warranty Safety Data Sheet (SDS) The Palm CO Carbon Monoxide Analyzer is intended to measure and display the concentration in the range of 0 to 25 PPM of carbon monoxide in com- 10.1 Disposal pressed breathing air tanks, intended for scuba diving. It provides continuous, fast, reliable, and accurate carbon monoxide measurements.
  • Page 3: General Safety Warnings

     DO NOT use another manufacturer’s sensor inside this analyzer: The 6.3. design of the electronics is intended for only the Analytical Industries Inc.  ALWAYS contact the factory if you are in doubt while troubleshooting. OSV-22-AF carbon monoxide sensors. Use of a different carbon monoxide...
  • Page 4: Start-Up

    3.3 Bump Testing: Prerequisite Gas Tests Prior to Start-Up and Use  Bump testing is recommended before each use of the Palm CO ana- If the analyzer is located in a clean source of ambient air and the display lyzer. To conduct the test, one exposes the sensor to a gas mixture of...
  • Page 5: Span Calibration

    1. The analyzer should be ON and located in a clean source of ambient air. attached to the bottom of the 2. PRESS the ZERO () key for 3 seconds. Palm CO. 3. The analyzer display will read “Zro”. Blocking the “vent” hole causes a 4.
  • Page 6: Operation

    6.2 Battery Replacement Changes in humidity will produce transients in sensor output that last for about The Palm CO Carbon Monoxide Analyzer is powered by two ten minutes. Therefore, it is recommended that at least ten minutes be pro- 1.5V AA alkaline batteries with an approximate life of 450 vided before taking measurements after a sudden humidity change, which may hours.
  • Page 7 6.2.1 Procedure: 6.3 Carbon Monoxide Sensor Replacement Place the analyzer face down on a flat surface and remove the four (4) DO NOT attempt to open or probe sensor. In event the sensor leaks, Phillips screws from the rear of the enclosure, FIG 2. refer to the Safety Data Sheet in Section 10.
  • Page 8: Reassembly Checklist

    To ensure proper operation after replacing the sensor or batteries check that: If the recommended corrective action does not resolve the problem return the  The overview of the Palm CO Analyzer reassembly, FIG 7, is followed. device to the factory for service. ...
  • Page 9: Warranty

    Limitations Carbon monoxide sensors and batteries should be disposed of in accordance Analytical Industries Inc. shall not be liable for losses or damages of any kind; with local regulations for batteries. loss of use of the analyzer; incidental or consequential losses or damages;...
  • Page 10: Specification

    11 Specifications...
  • Page 11: Quality Control & Calibration Certification

    12 Quality Control & Calibration Certification Customer: _______________________________ Date: __________ Pass Y/N Order No. _______________________________ Initial / Date Model: Palm CO Carbon Monoxide Analyzer S/N ____________ __________ Sensor: OSV-22-AF Carbon Monoxide Sensor S/N ____________ __________ Electronics: A-1199 Rev F1 PCB Assembly Main...

Table of Contents