Cleco 935302 Instruction Manual

4-fold for 26 v li-ion batteries

Advertisement

Quick Links

Instruction Manual
P1947E/EN
2015-07
Battery Charger, 4-fold for 26 V Li-ion batteries
Order no. 935302

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 935302 and is the answer not in the manual?

Questions and answers

Summary of Contents for Cleco 935302

  • Page 1 Instruction Manual P1947E/EN 2015-07 Battery Charger, 4-fold for 26 V Li-ion batteries Order no. 935302...
  • Page 2: Table Of Contents

    Contents Safety Warnings and information ..............3 Symbols on the product ................ 3 Basic requirements for safe working practices ........4 Designated use..................4 Items supplied / Transport Product description General description................4 Initial operation Troubleshooting Maintenance Service Technical data Dimensions in mm ................
  • Page 3: Safety

    Safety Copyright protection Apex Tool Group reserves the right to modify, supplement or improve this document or the product without prior notice. This document may not be reproduced in whole or in part in any way, shape or form, or copied to another natural or machine-readable language or to a data carrier, whether electronic, mechanical, opti- cal or otherwise, without the express permission of Apex Tool Group.
  • Page 4: Basic Requirements For Safe Working Practices

    Battery Charger Basic requirements for safe working practices CAUTION! Electrical safety  Do not operate the charger if the housing, power cable or plug are damaged. Do not use batteries which have been damaged or modified in any way. Batteries which have been ...
  • Page 5: Initial Operation

    Initial operation 3.1.1 Display Result Green continuous light Charging compartment ready: power supply available, no battery connected Red continuous light Battery being charged. Green flashing light Battery full: conservation charging Red flashing light, long Error in battery: defective or overdischarged battery. Red flashing light, short Charging electronics error.
  • Page 6: Maintenance

    Battery Charger Error Cause Measure The red continuous light is not lit when the The battery that is plugged in  Check battery for proper battery plugged in. has already been charged function. (red LED stays off). The battery contacts are not Plug the battery in again.
  • Page 7: Dimensions In Mm

    Disposal Dimensions in mm 530* * complete with battery and cable Disposal CAUTION! Injuries and environmental damage from improper disposal. Components and auxiliary materials of the charger pose risks to the health and the environment.  Separate the components of the packing and dispose of them by segregating them clearly. ...
  • Page 8: Ce Declaration Of Conformity

    Battery Charger CE Declaration of Conformity P1947E/EN 2015-07 1947b_1_5 en.fm, 21.07.2015...
  • Page 10 POWER TOOLS SALES & SERVICE CENTERS Please note that all locations may not service all products. Contact the nearest Apex Tool Group Sales & Service Center for the appropriate facility to handle your service requirements. NORTH AMERICA | SOUTH AMERICA Detroit, Michigan Louisville, Kentucky Lexington, South Carolina...