PL-1 SERIES II Thermostat

Installation Guide

Version 2.1
Acrolon Technologies, Inc.
19201 SONOMA HIGHWAY, SONOMA, CALIFORNIA 95476
Phone +1 (707) 938-1300, Fax: +1 (707) 938-1342
http://www.acrolon.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the PL-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Acrolon Technologies PL-1

  • Page 1: Installation Guide

    PL-1 SERIES II Thermostat Installation Guide Version 2.1 Acrolon Technologies, Inc. 19201 SONOMA HIGHWAY, SONOMA, CALIFORNIA 95476 Phone +1 (707) 938-1300, Fax: +1 (707) 938-1342 http://www.acrolon.com...
  • Page 3: Table Of Contents

    Table of Contents Chapter 1: Overview................1 Chapter 2: Installation................2 Mounting.................2 Internal Wiring..............4 Installing the LID............7 Applying Power..............8 Chapter 3: Specifications.................
  • Page 4: Chapter 1: Overview

    This manual covers installation of Acrolon's PL-1 thermostat., an industrial-grade temperature controller designed specifically for use wine tanks. The PL-1 should be mounted onto a protective ice shield on the tank and wired to the cooling and/or heating valves via 16-18AWG 300V wire run inside flex conduit Key Features: •...
  • Page 5: Chapter 2: Installation

    1. Install the four mounting brackets supplied with the thermostat per Figure 2. 2. Fasten the PL-1 thermostat to the ice shield per Figure 3 using four #10 x 3/8” long stainless steel self- tapping screws. Note that pilot holes might be required depending upon the material used for the ice shield.
  • Page 6 Figure 2 (above) Figure 3 (below)
  • Page 7: Internal Wiring

    (breaker-panel) of the building, in close proximity to the PL-1 thermostat(s) and clearly labeled as being the disconnect for the product. Compliance is checked by inspection. CAUTION: For continued protection against risk of fire, replace only with same type and rating of fuse.
  • Page 8 1. Pull one each of the following wires colors from the source power through the conduit to the inside of the PL-1 power supply: GREEN (Earth), WHITE (NEUTRAL), BLACK (LINE), RED (cool output), PURPLE or BLUE (heat output). Leave only enough extra length of wire inside the thermostat to allow for easy wire preparation and termination.
  • Page 9 8. Install the PROBE plug into PL-1 display at “JP8” location. 9. Reduce excess probe cable from within the PL-1 by pulling the cable back through the cable gland of the power supply and then tighten the gland to ensure a water-proof seal around the probe cable.
  • Page 10: Installing The Lid

    1. Verify internal power and probe wiring 2. Hold the PL-1 display assembly with your right hand with front panel against your palm. 3. Align inside right edge of display assembly with the right edge of the power supply assembly.
  • Page 11: Applying Power

    SECURELY FASTENED TO THE PL-1 POWER SUPPLY BASE. The PL-1 thermostat connects to the mains supply through permanent field wiring via circuit-breaker located in the electrical distribution panel of the building. This circuit-breaker serves as the disconnect for the thermostat and should be clearly marked as such in the panel.
  • Page 12: Chapter 3: Specifications

    Specifications Part Number: The part number scheme for the PL-1 thermostat is as follows: 6000-XXX Where: XXX: 120 or 024, indicates the power supply input voltage (120VAC or 24VAC) as measured between line and neutral Specifications: 6000-120: 120 Vac, 50/60 Hz, 0.05A Input Voltage 6000-024: 24 Vac, 50/60 Hz, 0.20A...